3 phase motor running on single phase (THANKS FOR THE COMMENTS REGARDING THE EARTH)

Опубликовано:

 

2 май 2015

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 255   
@scheppach69
@scheppach69 9 лет назад
A very informative video about the wiring of dual voltage motors which is usually a black hole to us mechanically minded. Thank you it has helped me, and I guess so many others in how it should be done.
@TheInfoworks
@TheInfoworks 9 лет назад
Just as an addition for your viewers information I have covered the selection of capacitor size in my series of videos on this subject. "How to do it, run a 3 phase motor on single phase supply". It is important to use an AC capacitor of the right voltage and capacitance. A higher voltage is not a problem, but lower is. A DC cap will go pop when connected to AC. Always enjoy your videos, and the quality of some of your close-ups when machining is tremendous, Cheers, Andy.
@doubleboost
@doubleboost 9 лет назад
Andy Reynolds Thanks Andy
@Esiggies
@Esiggies 8 лет назад
+Andy Reynolds If I may ask. I have a 3 Phase induction Motor 3HP 2.2 KW with 240 in and 3 phase out , which at present is setup with a variable frequency drive. I would like to run just on 240V as I need the variable frequency drive for another machine. First is this possible, what are my losses? and what size cap would I need. Regards Peter
@TheInfoworks
@TheInfoworks 8 лет назад
Peter I suggest you watch my 6 part series as this will answer most of your questions. With that size motor you will need a start cap as well as a run cap. The run cap should be about 50 Uf, but you will have to check the voltages whilst the motor is running. Cheers, Andy
@Esiggies
@Esiggies 8 лет назад
Thanks for your reply will follow up on videos and scratch my head a little less. Cheers
@telosfd
@telosfd 8 лет назад
+Peter Linch 3Hp motor is to big to run up in one phase.
@leoawitan3183
@leoawitan3183 7 лет назад
excellent tutorial,so much appreciated,about the delta,to star wye contact lines for 3phase,trans...
@clivebucknall1362
@clivebucknall1362 2 года назад
Hi John i did the same with my coolant pump, and did a bit of research and found that 70uf per horsepower is about as near as it gets, thanks for the videos and keep them coming, all the best to you and your wife, regards clive
@binks166
@binks166 9 лет назад
John, very useful information. I had no idea it was possible without using a 3 phase converter. Thank you, Harvey from Nebraska
@MsSomeonenew
@MsSomeonenew 7 лет назад
Concise, on topic and with functional example, that is how instructional videos need to be made. I went through 10 other videos before this that made everything completely and utterly unclear.
@thebeekeepersworkshop
@thebeekeepersworkshop 2 года назад
Me too they write the title in English they jabber on in another language
@TEREZKATERKA100
@TEREZKATERKA100 5 лет назад
Zrozumiteľne jednoducho vysvetlené. Vďaka.
@jonerasmus9399
@jonerasmus9399 Год назад
Great vid thank you sir , my hat is off to you . If only my tech school taught me this ....
@MIGHTYcbu
@MIGHTYcbu 2 месяца назад
Thank you, great information . I was wondering how these type of motors should be connected, but now I know. because the windings are straight across from eachother, U1 opposite of U2 etc, it made no sense to me. I expected the windings to be like in a 400/690 motor, U1 opposite W2 etc
@FredMiller
@FredMiller 9 лет назад
I enjoyed this with my Sunday morning coffee! Thanks for sharing! Fred
@doubleboost
@doubleboost 9 лет назад
Fred Miller Thanks Fred
@adonismallare9816
@adonismallare9816 9 лет назад
Thank you so much sir for your very informative video...
@evrenforest2578
@evrenforest2578 6 лет назад
Lovely explanation. Thanks
@sameldimalao3454
@sameldimalao3454 8 лет назад
very nice demonstration i got it buddy.....thankssss
@AstraWerke
@AstraWerke 9 лет назад
The rule for capacitors usually is 70µF per Kilowatt of output. If the value is too low, the motor won't start properly, if it is too high, there will be extensive heat buildup which is why some motors have a starting capacitor that is only activated for start-up and then disconnected. The running capacitor has a lower value and ensures the motor stays cool during run.
@doubleboost
@doubleboost 9 лет назад
Adrian Straub Thanks for that
@lordzsimban5074
@lordzsimban5074 8 лет назад
very nice video sir, simple and clear thank you for sharing your idea...
@debihedderwick1160
@debihedderwick1160 8 лет назад
Thanks for this! Im doing the exact same project! capacitor is on order!
@umarqazi1372
@umarqazi1372 6 лет назад
Good information nice to meet you
@user-bd1qv1kz8p
@user-bd1qv1kz8p 7 лет назад
perfect !!! thank you yiannis
@ronnor58
@ronnor58 7 лет назад
good video, thank you, great job
@charlesbeck6034
@charlesbeck6034 6 лет назад
Thank u sir I bin trying for 4days to wire a 3 face motor
@imysteryman
@imysteryman 8 лет назад
John Thanks for sharing John F
@amino-acid4919
@amino-acid4919 6 лет назад
I love this video.... Simple and nice.... Weldon bro
@MaturePatriot
@MaturePatriot 5 лет назад
Here in the states we are always trying to run 220vac 3ph from 220vac 1ph. I built my own 5hp RPC and have the voltages pretty well balanced on each phase, and kept the amp draw at a low level. I will only be able to run one of my machines at a time, but then there is only one of me.
@peterprobst316
@peterprobst316 6 лет назад
Best Video! Super.
@omar-qe6dy
@omar-qe6dy 3 года назад
Gut gemacht, vielen dank.
@ytube835
@ytube835 Год назад
Amazing Thank you very much "Shikuren '
@kamaleshyadav3708
@kamaleshyadav3708 7 лет назад
Nice video keep it up.
@faridmak6738
@faridmak6738 8 лет назад
thanks Andy. I get some new idea
@phooesnax
@phooesnax 9 лет назад
Nice job.
@coswepanggayan4841
@coswepanggayan4841 2 года назад
It's clear illustration
@edgar8799
@edgar8799 7 лет назад
nice work..
@tsheritageengineering
@tsheritageengineering 9 лет назад
Did that with the pump on my harrison last week. Used a 4uf motor start capacitor, £2.50 on eBay. Runs well. Did it on my Boxford years ago and it has never given bother.
@stefantrethan
@stefantrethan 9 лет назад
Tony Simons It should be a run capacitor, not a start capacitor. Start capacitors are only rated for a few seconds service (in motors with centrifugal switch) and will overheat if used as run capacitors.
@tsheritageengineering
@tsheritageengineering 9 лет назад
must have been a run one as its been fine for 10 years or so
@MdSaleem-ob2ue
@MdSaleem-ob2ue 7 лет назад
Tony Simons q
@DSIreland
@DSIreland 5 лет назад
I got a lathe and i think i can do this what capacitor do I need
@elidonner167
@elidonner167 2 года назад
Thank you 👍
@billmoran3812
@billmoran3812 9 лет назад
This will work on a small, lightly loaded motor. However, you will lose torque, because the windings are in balanced. The capacitor does give it sufficient torque to start, but because it does not shift voltage by a full 120 degrees phase angle, that is why the voltages are unbalanced. This will create additional heating in the motor. If this were a heavily loaded motor, it would overheat and eventually burn out. I'm an electrical engineer, for the past 40 years, this is what I do for a living. There are small variable frequency drives that will allow a small motor to run on 3-phase power from a single phase source.
@billmoran3812
@billmoran3812 8 лет назад
+Lorena Dervishi , no amount of Capacitance alone will create a third phase at 120 degrees. 90 degrees of angle is sufficient to allow starting of a rotating motor, but the current flow to the windings will remain unbalanced, causing heating of the motor. Keeping the capacitance in the circuit will result in a very significant leading power factor that will cause further heating of the windings. The only way to create true 3-phase power from a single phase source is either a motor driven synchronous generator, or an inverter. Multiple 3-phase motors running off a rotating phase converter will improve the balance between phases, but not entirely eliminate it.
@vernonjones3613
@vernonjones3613 6 лет назад
B
@duncanwalker7380
@duncanwalker7380 5 лет назад
Good sir I needed to ask, I have a 380v 3.0kw motor that I need to convert to single, what would be the size of capacitor ratings without Burning thing's out. Plus I have a theory. To create 3 phase power can take a single phase wire and connect via looping from one MCB to another whereby creating 3 outputs Of Power from one line which now gives me 3 phase power . Or am I wrong
@somadinafanz6568
@somadinafanz6568 5 лет назад
Good day engineer, please I want to know which of these three phase will have best efficiency, STAR/440 OR DELTA/220?
@markodonovan9921
@markodonovan9921 3 года назад
Mr Moran, if I were to use a small three phase motor designed for 380v in delta configuration with a vfd that outputs 3 phase 220volt, do you think I'd have any issues. The motor is for a pool pump only .75hp.
@pedrojardim1163
@pedrojardim1163 7 лет назад
THANKS HELP ALOTS
@RickRose
@RickRose 9 лет назад
So the way I interpret what you've done is, you've built a DIY static phase converter. I am, as always, impressed. Cheers to Debs!
@misaelharry6613
@misaelharry6613 2 года назад
i guess im asking the wrong place but does any of you know of a tool to get back into an Instagram account..? I stupidly forgot my login password. I would appreciate any help you can give me.
@hayeselisha2237
@hayeselisha2237 2 года назад
@Misael Harry Instablaster :)
@misaelharry6613
@misaelharry6613 2 года назад
@Hayes Elisha i really appreciate your reply. I got to the site through google and Im in the hacking process now. Takes a while so I will get back to you later with my results.
@misaelharry6613
@misaelharry6613 2 года назад
@Hayes Elisha it did the trick and I finally got access to my account again. Im so happy! Thank you so much, you really help me out!
@hayeselisha2237
@hayeselisha2237 2 года назад
@Misael Harry happy to help :D
@one4stevo
@one4stevo 9 лет назад
Nice job explaining how to to rewire the motor. i remember when i put a vfd and had to rewire the motor to delta. i had no idea so i got a mate to do it.. looks simple after seeing this great job. hope debs doing well :)
@doubleboost
@doubleboost 9 лет назад
one4stevo Debs is good
@mdnasimnajar6347
@mdnasimnajar6347 8 лет назад
very nice video Sar star delta canecan
@keongjawi1059
@keongjawi1059 5 лет назад
Good .....information Thank.s ....
@SeanBZA
@SeanBZA 9 лет назад
An alternative for the small motors is to get a motor in the same frame size made by the same manufacturer that is the single phase variant and swap the stator sections. The rotor will typically be the same size and then it will be single phase. The leftovers you can put back together and have a 3 phase motor, which somebody else can use again. Works on those motors with special end bells or specially modified shafting, and can work quite well. At least with this conversion it will run cooler.
@TheInfoworks
@TheInfoworks 9 лет назад
yes, but you have to source another identical motor, this way is low cost, no real hassle, and you can use caps from old flourescent light fittings. Cheers
@lawkeetee5888
@lawkeetee5888 6 лет назад
thank a lot
@parowdan
@parowdan 7 лет назад
excellent video ....i always wanted to know why they had a capacitor on there thank you so much....
@obyukil7478
@obyukil7478 8 лет назад
I'm interested to learn more about the new configuration
@edwinrohweller
@edwinrohweller 7 лет назад
Great video! You should probably say something about discharging the capacitor at 6:23, before playing with the leads. Otherwise, very informative.
@danallured5806
@danallured5806 9 лет назад
Hi there john, I've been an avid watcher of your vids since I first bought a little 100 year old relmac lathe 18 months ago or so, I have learnt so much and really enjoying my hobby. This vid has made me need to get in touch! I have a 3 phase motor I was selling on ebay to get a single phase to run my other small hobby lathe,but after watching this I have found mine can be converted too,just one question, you say that by swapping the connections over will reverse the direction of the motor..... is there anything available that can be wired in,such as a switch that could reverse the motor when needed( threading small threads,for instance) and how would it be wired in? thanks for taking the time to make these vids, you have no idea how valuable they are to a 44 year old novice such as me! congrats on the channel and love to debs,my wife and I are still including her in our prayers( I give lynn an update everytime you give us an update!) best wishes. Dan,leicester UK
@TheJask101
@TheJask101 6 лет назад
Great great video! Could you make a video on star delta theory ?
@peterfrancis3865
@peterfrancis3865 4 года назад
Nice
@rjchannelpro9802
@rjchannelpro9802 6 лет назад
nice
@khunhnusaiphin1282
@khunhnusaiphin1282 6 лет назад
ฟังไม่รู้เรื่องเลย โท่ชีวิต T T
@andrewmicas4327
@andrewmicas4327 9 лет назад
John if you look at the original links I bet there are will be two stuck together and appear a just one. Swopped plenty over as we used single phase inverter to save cost (they give out 220/240v 3phase) on industrial Carpet Backing plants.
@doubleboost
@doubleboost 9 лет назад
ANDREW MICAS There was only 2 like you say normally there is 3
@tigrmatch8962
@tigrmatch8962 7 лет назад
شكرا لك
@narendergodara1992
@narendergodara1992 2 года назад
perfect knowledge 👌👌👌👌👌👌
@zlatkomozetic2822
@zlatkomozetic2822 3 года назад
Excellent video. But what size capacitor do we use on which motor power? Is there any formula for that or do we orientate only to the supply voltage? Any help would be appreciated.
@SeanBZA
@SeanBZA 9 лет назад
There is an earth screw in that frame, partly hidden under the terminal block, the earth must go to that from the power cord. You can do additional earths, but the cord earth must go direct to the frame. That way if the motor shorts to earth and you pick it up you will still have the motor earthed, and will not get a shock.
@doubleboost
@doubleboost 9 лет назад
SeanBZA Thanks for thatIt was not earthed on the lathe
@SeanBZA
@SeanBZA 9 лет назад
Now try to fit that spaghetti inside the cover and close it, plus use a second cable gland for the capacitor. You should get a motor run cap with integrated lead, so that you have no exposed terminals outside. That way you just use a large P clip or a cable tie to hold it to the motor side.
@doubleboost
@doubleboost 9 лет назад
SeanBZA Now that I have it running I will get a new "run cap"No exposed terminalsI ran a similar set up on my Boxford for 10 yearsThanks again for the heads up on the earth tag RegardsJohn
@supermazingerz72
@supermazingerz72 8 лет назад
+doubleboost awesome video, can I do this with a 5hp 3PH for a table saw? Thanks in advance
@Orgakoyd
@Orgakoyd Год назад
The relationship between Delta and Star (Wye) is 1.73 (square root of 3). So 220/380, 230/400, 240/415 or 277/480.
@budakinsaf80
@budakinsaf80 6 лет назад
thanks
@bourekbamohamed9310
@bourekbamohamed9310 8 лет назад
شكرا
@imbaragatv3167
@imbaragatv3167 4 года назад
Good
@yuriy6414
@yuriy6414 7 лет назад
220/380 V (230/400V)
@bigun447
@bigun447 9 лет назад
I somehow expected Mr. Bozo to go ZAP-POP-FIZZLE At least you have 3 phase. It would cost thousands to have it ran to here. So we are stuck with converters or VFD units. The nearest 3 phase is well over a mile away. Good video.
@jusb1066
@jusb1066 9 лет назад
Big'un44 He doesnt, he uses a converter too, and thats wjhy he converted this to 240v to save always having to run his converter, passes Big'un44 some coffee to keep him awake for the video! :}
@brendan454
@brendan454 9 лет назад
Hey john, im wanting to run coolant on my lathe. Ivw got the setup but ive always herd if your not going to use it everyday it will go "off" and start to smell. Unless theres better coolants now days?
@user-bd1qv1kz8p
@user-bd1qv1kz8p 7 лет назад
please tell us about the perfect capacitor in any case thankyou yiannis
@IbrahimKhan-st3yp
@IbrahimKhan-st3yp 6 лет назад
It really helps me with my comprrssor the other thing i need to know can i change the speed of the motor with same delta connection my motor runs a little slow
@samiromarchege804
@samiromarchege804 6 лет назад
nice illustration but ca you explain how connect a 3 phase synchronous motor from the power supply using a contactor and thermal overload
@gregcacace8313
@gregcacace8313 8 лет назад
Can you tell me if this reconfiguration will also work with other equipment? How about 3 phase commercial ovens to 1 phase 240v?
@davisonnyatinyirenda4626
@davisonnyatinyirenda4626 Год назад
Very good work. How are you doing sir.
@Yoyo378
@Yoyo378 6 лет назад
Hello Scotland :D
@tigrmatch8962
@tigrmatch8962 7 лет назад
Merci de votre avis
@WAVETUBE84
@WAVETUBE84 9 лет назад
the motor will run cooler and more efficiently on the 440 "star" configuration. But, it won't make a difference in your lifetime. Just saying.
@user-fp3np5xm9q
@user-fp3np5xm9q 5 лет назад
👍👍👍
@SuperChromatic
@SuperChromatic 8 лет назад
Hi, Tried your method on a Lowara star /delta motor. I triple checked the wiring, started it and hummed, smoked and the shaft hardly revolved. Any ideas on what l may have done wrong? I used a 20uF capacitor. Cheers.
@alex993cc1
@alex993cc1 9 лет назад
run cap for the win. also did you measure the difference in current drawn? being a coolant pump its not going to be extremely "thirsty" tho ;-)
@jitendrakumargupta2331
@jitendrakumargupta2331 6 лет назад
supar
@edgehead13
@edgehead13 8 лет назад
Hey, Is there a reason why you connected the Capacitor to the middle and right slot? does it matter where it's connected to? Can i connect one side of my capacitor to the left ring and the other side to the right ring and leave the center ring without a capacitor lead?
@deretano_fondelli
@deretano_fondelli 9 лет назад
Italian pump :D
@1989beasley
@1989beasley 5 лет назад
If I had a 3 phase water pump could I wire it up to single phase and have it running constantly to run a pond?
@bikashsharma5618
@bikashsharma5618 6 лет назад
Hello friend
@karvakferenc
@karvakferenc 7 лет назад
220V/380V
@theholyquran755
@theholyquran755 Год назад
how to get the capacitance. Thank you for this informative video
@naturallivingentitywithin451
@naturallivingentitywithin451 7 лет назад
I am thinking of doing this to a 3/4 hp motor on a tool & cutter grinder. A capacitor is far cheaper than a converter or inverter.😕hmmm..... As it is under 1hp, will the motor still overheat? I also need the machine to be able to switch into reverse as well. Will the machine still switch into reverse via the forward and reverse switch with the capacitor fitted to the motor or would I be better of just investing in an inverter?....
@hitharodv3304
@hitharodv3304 Год назад
👍🏼👍🏼👍🏼👍🏼
@firstnamelastname4722
@firstnamelastname4722 4 года назад
547 dislikes = 547 hot ass motors
@gazdkw82
@gazdkw82 5 лет назад
Isnt that 2 phases (1 230v and another from the capacitor) and then a neutral? How do you figure it is 3 phase?
@stefantrethan
@stefantrethan 9 лет назад
John your electrical work looks about as bad as my machine work. ;-) The capacitor voltage will go down under load anyway. Finally we will have running water at the mill, nice!
@stuarthearn9890
@stuarthearn9890 3 года назад
ah looks like motor on my cazenueve lathe, now, I just scored two hydraulic power packs 2.2 kw wired in delta 220, I swing them to star, so i generate my 3phase from a Lincoln vantage 400 gives 17kw 440 V the controls are 24volt dc, came from a ship,so i will need swap solenoids to 230ac can you advise how powerful a 3ph motor will run as you've done hear on a cap start, you taught me something today , THANKS
@Tsagami
@Tsagami 7 лет назад
What is the suitable capacitor μF? Depends how many HP is the motor?
@geralda2676
@geralda2676 7 лет назад
how to check a compatible cafacitor in the mottor to changes a single phahe?
@ameenghuloom1346
@ameenghuloom1346 5 лет назад
good day how to find the right capacitor for any motor. i have air comprasor and its working on 3 phase and i need it to work on single phase. how to find the right capacitor size thanks for you
@jameskinuthia7605
@jameskinuthia7605 6 лет назад
what is the value of the capacitor
@ricktv3514
@ricktv3514 4 года назад
Greetings, is that a start compacitor or a run compacitor ?
@peternewby2109
@peternewby2109 9 лет назад
Hi John Just a bit of information I do not know if you are aware but there is a model engineer exhibition at Harrogate show ground this weekend Friday to Sunday. There are lots of lathes mills plus accessories plus of course lots of engineering models. For more information click onto National Model Engineering Exhibition Harrogate 2015. Regards Peter Tyneside Model Engineers
@doubleboost
@doubleboost 9 лет назад
Peter Newby Thanks for that PeterI will be there on Saturday
@peternewby2109
@peternewby2109 9 лет назад
Morning John Make yourself know I am on the Tyneside Model Engineers stand you have a few fans there. Regards Peter
@ammaralyasiri4191
@ammaralyasiri4191 7 лет назад
how can i calculate the value of capacitanc thank you very much
@nandimadayas9318
@nandimadayas9318 4 года назад
Hai my dear good video vison please let me know the caperciter how much uf we should used i am dias From srilanka bentota please reply me soonly thanks
@306zubair
@306zubair 6 лет назад
what is the value of capacitor and voltage rating?
@erdene-ochirmijid4040
@erdene-ochirmijid4040 8 лет назад
how I correct capacitor choose relative any motor power?
@kobudoka1165
@kobudoka1165 7 лет назад
I´m sorry, but in delta config it´s signed as 400 V only (really it is 380 V)
@11ildiko11
@11ildiko11 4 года назад
a small glitch : 220v/ 380v----- 240v/ 440v !
@maksimyahia5227
@maksimyahia5227 6 лет назад
Will this method work for all 3 phase motors ?
@amitbambulkar2078
@amitbambulkar2078 6 лет назад
sir also explain the this motor starter connection.
@mohapistevansmatlokotsi1119
Questions :what's the size of the capacitor
Далее
Star Delta Starter Explained - Working Principle
11:08
BABYMONSTER - ‘FOREVER’ M/V
03:54
Просмотров 25 млн
двигатель 380 в 220
8:12
Просмотров 1 млн
Lathe VFD 1: How to wire a 3-Phase motor and VFD
24:16
Просмотров 306 тыс.
How to run Three phase to Single phase
16:27
Просмотров 23 тыс.
COMO TRANSFORMAR MOTOR TRIFÁSICO A MONOFÁSICO
12:54
BABYMONSTER - ‘FOREVER’ M/V
03:54
Просмотров 25 млн