I don’t know your exact situation, but I do know that crane scopes out by a boom pinning system. Your telescopic cylinder can only extract and retrieve boom sections it can only reach. I think you inner telescopic cylinder is only 37ft long. So if your trying to retract section 5 , your last section, you can’t without scoping in all your other sections before it. Then your able to reach it with the telescopic cylinder, adjust it whether it’s bringing it in or scoping it out. If you give the computer a command being out of sequence. It won’t respond. Hope that helps
A tadano doesn't work the same as a liebher or grove, all boomsections go out simultaneously and you don't pin sections, it's lots simpler and lots faster!
So if you have sections 5 and 4 out can you put out section 3 if you need more stick or will I have to suck the boom back in all the way the put out sections 5 ,4,3
Did you figure it out already? What size tadano are you on? There should be a button on the aux lever one you max out all sections hit that button and it should send the last section out