Тёмный

Testing the Fieldpiece VP67 Vacuum Pump 

Apartment Maintenance Pro
Подписаться 43 тыс.
Просмотров 8 тыс.
50% 1

Опубликовано:

 

14 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 25   
@elijahgoodman3140
@elijahgoodman3140 4 месяца назад
I bought one, and after watching your video, I'm ready to putvit in service. Thanks.
@jerelcaesar1053
@jerelcaesar1053 4 месяца назад
It's very convenient and easy to use 😅
@jerelcaesar1053
@jerelcaesar1053 4 месяца назад
Once you know what how to use it
@chrometrey57
@chrometrey57 5 месяцев назад
Love watching another hvac tech in the field
@IzzyDave
@IzzyDave 2 месяца назад
Excellent Video, may I ask why 3 vacuums? Not trying to critique just genuinely curious. Love learning something new.
@ApartmentMaintenancePro
@ApartmentMaintenancePro 2 месяца назад
By flowing nitrogen between vacuums you push out moisture faster. If you let minimum moisture in and flow nitrogen while brazing it may not be necessary
@July4.1776
@July4.1776 2 месяца назад
It’s called the Triple evacuation method.
@lngtrvl8447
@lngtrvl8447 2 месяца назад
I just use the fieldpiece micron gauges they do an tell me everything for a vacuum ect..500 our under is a perfectly acceptable vacuum and why three vacuums?? I want that pump I have the model that came out just before that one vp85 8cfm the ten is definitely nice!!
@teeknowstech
@teeknowstech 2 месяца назад
My friend what is that extinction piece called on your micron gauge
@backwoodsrunner7
@backwoodsrunner7 5 месяцев назад
Shouldn’t have the micron gauge so close to the vacuum pump…you want to put it on the liquid line as far from the pump as possible and pull through the suction to ensure a deep vacuum.
@ApartmentMaintenancePro
@ApartmentMaintenancePro 5 месяцев назад
I can tell from this comment you didn't watch the video, on the third vacuum the micron gauge is on the liquid line and under 100 microns. I'd say I pulled a pretty deep vacuum. Thanks for watching, even though I don't think you did. I'm also pulling through the suction and liquid, as the manufacturer recommends in the install sheet.
@vapourkl5324
@vapourkl5324 3 месяца назад
@@ApartmentMaintenancePro TLDW
@chesstime356
@chesstime356 6 месяцев назад
Good job man
@ApartmentMaintenancePro
@ApartmentMaintenancePro 6 месяцев назад
Thanks for watching 🛠
@billyflanagan9657
@billyflanagan9657 3 месяца назад
Nice job
@jamminwrenches860
@jamminwrenches860 6 месяцев назад
Good work
@ApartmentMaintenancePro
@ApartmentMaintenancePro 6 месяцев назад
Thanks 👍
@01allam
@01allam 6 месяцев назад
Why do 3 vacuum pulls?
@ApartmentMaintenancePro
@ApartmentMaintenancePro 6 месяцев назад
Just to test it wasn't absolutely necessary in this application. But if you have a big system with lots of moisture the triple evacuation can speed up the process of moisture removal.
@01allam
@01allam 6 месяцев назад
@@ApartmentMaintenancePro ok
@billyflanagan9657
@billyflanagan9657 3 месяца назад
I wish it had a check value
@elmerramirez1215
@elmerramirez1215 6 месяцев назад
Are you rich?
@ApartmentMaintenancePro
@ApartmentMaintenancePro 6 месяцев назад
No, I'm Dave
@vapourkl5324
@vapourkl5324 3 месяца назад
@@ApartmentMaintenancePro in the future HVAC people are top earners due to global warming
Далее
jb dv-200n vs fieldpiece vp67 hvacr
8:28
Просмотров 9 тыс.
Comparing & Testing Several Valve Core Removal Tools
29:01
What's in my Veto Tech Pac - Apt Maintenance Edition
12:49
Vacuum Pump Oil Change Experiment by Fieldpiece
18:56
Tips on pulling a vacuum with the VPX7
4:06
Просмотров 51 тыс.
Getting paid with TAMALES in Mexico
8:03
Просмотров 13 тыс.