Тёмный

The ac air is not cold !! 

Cold Flash AC
Подписаться 833
Просмотров 31 тыс.
50% 1

Hello guys please leave a like and a sub , thank you stay cold
( / @coldflashac6443 )
//Recommended videos:▶️Compressor running backwards • Compressor running bac...
▶️ Hacked Customer filter • Filter installed incor...
▶️ ac compressor isn't starting ! • ac compressor isn't s...
Check this products
www.icybreeze.com?afmc=kt
//Let’s Connect:👉 Subscribe: / @coldflashac6443
//About me:Hvac Tech and Real Estate Agent , fighting to be the best , follow me on my adventure and lets find out the best of us //
Disclaimer:Links included in this description might be affiliate links. If you purchase a product or service with the links that I provide, I may receive a small commission. There is no additional charge to you! Thank you for supporting me so I can continue to provide you with free content each week!

Опубликовано:

 

11 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 49   
@Menu2Sports
@Menu2Sports 2 месяца назад
Great info, fixed my own for $30 as a result.
@coldflashac6443
@coldflashac6443 2 месяца назад
Excellent!
@justinberrett7479
@justinberrett7479 2 года назад
Thanks for posting your videos. I like the length and details-1thing I would like to see on them is what your ambient temps are when you are showing pressures. Thanks For my record I subbed at 259
@coldflashac6443
@coldflashac6443 2 года назад
Comments like this make me keep going! Thank you sir ❤️❤️ ok i will !
@SatoriSoul
@SatoriSoul 2 года назад
While watching the video I noticed you replaced a 1-pole contactor with a 2-pole (without a jumper between L2 and T2.) I am guessing the system has/had a crankcase heater which explained the 1-pole contactor. By removing the shunt won't the compressor need to work harder to start up, shortening its life? Or perhaps the weather precludes the need for a crankcase heater where you live? Think I noticed a heater attached further in the video. Please elaborate, I am curious to know.
@chesstime356
@chesstime356 Год назад
Lennox coil water wash only , but nice video keep it up .
@coldflashac6443
@coldflashac6443 Год назад
👍
@vkblue317
@vkblue317 2 года назад
Based on the videos I’ve watched on RU-vid those capacitors seem to be the most common problem.
@coldflashac6443
@coldflashac6443 2 года назад
yes ! and clogged drain lines here in florida
@tomtheplummer7322
@tomtheplummer7322 2 года назад
...and now you are certified to to swap and drop HVAC🤣
@MamaBear6684
@MamaBear6684 2 года назад
Great explanation and attention to detail. I have a condo florida and had to have the fan motor and assembly replaced. It was frozen like a huge block of ice. I got there just in time before it flooded. That was very expensive. 😬
@coldflashac6443
@coldflashac6443 2 года назад
@@MamaBear6684 thank you 🙏🏼 , might be a good idea to have a nest thermostat so you monitor your temperature and tell when there’s an issue 👍
@MamaBear6684
@MamaBear6684 2 года назад
@@coldflashac6443 Thanks I'll look into it 🙂
@SFInspector2211
@SFInspector2211 2 года назад
Good information but it's really hard to follow you when you're constantly moving the camera. If you could pause the camera for a few seconds in each object you're talking about as you go along it will make it much easier and understandable to follow. Thanks!
@coldflashac6443
@coldflashac6443 2 года назад
Thanks for comment
@joseorta9928
@joseorta9928 2 года назад
Whats the voltage value on the low voltage coil 24V on the contactor??
@coldflashac6443
@coldflashac6443 2 года назад
I always check for 10-20 ohms on the 24v coil, but this is the Second cap replacement in this unit in 1 year interval , burned contacts and pitted that why i changed it , better than coming back for another service call diagnostic and changing another cap and finally replacing the contactor , putting stress on that compressor windings
@mayankmishra03
@mayankmishra03 2 года назад
Isnt the Capacitor used to run the fans in the outside unit? If fans are running fine and still AC not blowing cold air, could this still be faulty capacitor or something else? I have already cleaned the coils for any bloackage but still its not blowng cold air so what next should I do?
@TheRealRenn
@TheRealRenn 2 года назад
My evap coil is icing up starting at the bottom of the A-coil. Both evap and cond coils are sparkly clean and the evap coil fan inside the house is running on high. DAT is only about 70 degrees with an EAT of 78-ish. I’m not a refer guy, so this is a mystery for me.
@coldflashac6443
@coldflashac6443 2 года назад
Check Freon pressures and let me know
@TheRealRenn
@TheRealRenn 2 года назад
@@coldflashac6443 …will do. This time of year all I can say is I’m ‘scheduled’..lol
@chrissipple1018
@chrissipple1018 Год назад
What is DAT and EAT. I've been in this trade 40 years and I've never heard of that. What your measuring id called the Delta T. Funny
@chrissipple1018
@chrissipple1018 Год назад
@@TheRealRenn That's funny
@chrissipple1018
@chrissipple1018 Год назад
@@TheRealRenn Dream on. Another handy man on RU-vid.
@MrGelly70
@MrGelly70 2 года назад
I want to learn how to work on these type of systems and get certified. Where do you suggest I start?
@coldflashac6443
@coldflashac6443 2 года назад
Get your epa license from a tech school or certified company, start as a helper too will help 👍 good luck brother
@abrahamkartey798
@abrahamkartey798 2 года назад
So mostly when the compressor sounds like that, I always thinks it's the compressor so what should come into my mind first when I held this kind of noise?
@shawnd567
@shawnd567 2 года назад
Replace the capacitor
@seandudek2019
@seandudek2019 2 года назад
Humming is almost always capacitor. 1/3 of my repair calls are capacitor although you have to be careful because there may be a reason capacitor goes bad. Always check amps after replace
@gibb2500
@gibb2500 2 года назад
Does the capacitor go out after only two summers?
@josetorres3355
@josetorres3355 2 года назад
What was wrong with the contactor?? Why did you reccomended for the customer to change it?
@coldflashac6443
@coldflashac6443 2 года назад
burned contacts , after a while they end up eating more capacitors .. thanks for the comment
@tomtheplummer7322
@tomtheplummer7322 2 года назад
Contactors are like points in olde car ignitions. They draw sparks when energized and wear out. It’s about time the contactors get engineered to use solid state relays by manufacturers. They are not too expensive. SSRs are used in all types of applications, especially where moisture or combustion may occur.
@bruce8572
@bruce8572 2 года назад
@@tomtheplummer7322 I recommend the Emerson Sure Start solid state switch. More expensive, but worth the $$.
@pullingthestrings5233
@pullingthestrings5233 2 года назад
Without watching the video in going to guess it's the capacitor not starting the compressor but working on the fan.
@coldflashac6443
@coldflashac6443 2 года назад
Good job brother! ❤️
@pullingthestrings5233
@pullingthestrings5233 2 года назад
@@coldflashac6443 bro i just don't get it why these caps are just not build like the polychlorinated biphenyls (PCBs) days. It's like things get worse and worse.
@coldflashac6443
@coldflashac6443 2 года назад
@@pullingthestrings5233 not even cars I agree , service is really busy now days
@pullingthestrings5233
@pullingthestrings5233 2 года назад
@@coldflashac6443 i don't doubt it. I did AC work for about 10 years and summer was always crazy. Used to gate being on call because every time i would dose off, RING RING went my phone.
@coldflashac6443
@coldflashac6443 2 года назад
@@pullingthestrings5233 all the time bro , thank god we have a night shift team no more on call for me
@susanazapata9205
@susanazapata9205 2 месяца назад
Im tired this darn machine a 1 1/2 qn 2 service calls they supposed to have filled n 24 hr later no cold air secon tine refill an lasted 48hrs the machine doesn’t stop n know not blowing air have been looking for a leak n nothing, what else can it be
@coldflashac6443
@coldflashac6443 2 месяца назад
If is loosing freon it has a leak if is hard to find looks like you need an isolation test meaning pressure all the components indoor unit line set and outdoor unit come back in 2 or 3 days and see if it lost nitrogen pressure, this is not an advice contact a licensed professional thanks
@MysticalMe131
@MysticalMe131 2 года назад
Can you come check ours. Its running but hardly any cold air. Would it be low on Freon???
@MysticalMe131
@MysticalMe131 2 года назад
Are you in Channelview Texas area, Houston,??
@coldflashac6443
@coldflashac6443 2 года назад
its probably low on freon , but you have to check first , no I leave in Florida ,sorry , thanks for the comment 👍
@Austrian_blood
@Austrian_blood 2 года назад
@@coldflashac6443 where in Florida?
@Miguel-dy3fh
@Miguel-dy3fh 2 года назад
This video describes the same issue you’re experiencing. He just repaired the unit by changing out the start capacitor. Freon/Refrigerant doesn’t dissipate. Therefore, it is unlikely your unit is low on refrigerant. Unless, there is a leak somewhere. Not sure why the creator says you may be low on Freon when he literally encountered a similar issue as you are experiencing and it wasn’t indicative of low refrigerant levels.
@coldflashac6443
@coldflashac6443 2 года назад
@@Miguel-dy3fh hardly any cold air could be freon , stuck heater, bad txv , restriction on the evaporator coil and more …., if the compressor was off do to a bad capacitor that house temp is going super high , thats why we have to check first , thanks for the comment 👍👍❤️
Далее
ac compressor isn't  starting !
10:33
Просмотров 55 тыс.
How To Clean Your Air Conditioner Condenser
13:09
Просмотров 2,3 млн
HVAC Is The Compressor Bad?
9:33
Просмотров 1,7 тыс.
Goodman Air Conditioner Runs but Not Blowing Cold
5:48
Compressor running backwards do to a power surge
8:41
8 Reasons Why Your AC is Freezing Up
9:02
Просмотров 1,7 млн
Top 5 AC Problems and How to Fix Them
16:28
Просмотров 879 тыс.