The Easy Way To Install Power To Your Shed - Domestic Electricians Life UK - 

JRC Electrical
Подписаться 7 тыс.
Просмотров 108 тыс.
50% 1

Thanks for watching, if your enjoying our content as much as were enjoying making it then please consider subscribing to the channel and smash the bell icon so you dont miss future uploads.
Check Out Tradify For A Free 14 Day Free Trial Use Code "JRC50" For 50% Off Your First 3 Months:
bit.ly/3RFgnBd
Join this channel to get access to perks:
/ @jrcelectrical

Наука

Опубликовано:

 

4 авг 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 156   
@johnmcdonald8696
@johnmcdonald8696 4 месяца назад
This bloke loves himself
@JRCElectrical
@JRCElectrical 4 месяца назад
Cheers someone has got to
@JIBS.
@JIBS. Год назад
Must've missed this video. Superb mate. Really enjoying your content
@JRCElectrical
@JRCElectrical Год назад
Thanks mate appreciate it a lot
@gco3579
@gco3579 Год назад
Came for the tutorial, subscribed for the banta! 👌
@JRCElectrical
@JRCElectrical Год назад
Legend thanks dude
@johnmcdonald2736
@johnmcdonald2736 2 месяца назад
Thanks Guys I’m I the process of running electric into a New Shed 👍
@JRCElectrical
@JRCElectrical 2 месяца назад
Your welcome sir, we have just released another video step by step
@tonysnowdon1633
@tonysnowdon1633 9 месяцев назад
i’ve done meself a mischief if we’re thinking of the same video when he goes fishing thanks for bringing back that memory need to bleach my eyes again
@JRCElectrical
@JRCElectrical 9 месяцев назад
Hahahahahahaa 😂😂😂😂😂 the Aussie?
@NM-gr1iq
@NM-gr1iq Год назад
Top class laugh lads, and great work.
@JRCElectrical
@JRCElectrical Год назад
Thank you sir much appreciated
@mensamoo
@mensamoo Месяц назад
wanted to see the run along the outside wall. Also the depth of the wire in the garden. Thanks for the vid tho....
@JRCElectrical
@JRCElectrical Месяц назад
Cable was just cleated to the wall if I remember correctly, cable wasn’t burried very deep as it wasn’t at risk where it was
@woody8942
@woody8942 6 месяцев назад
Hi jack getting to nearly have watched all your videos brother short and sweet to the point carry on making your videos as they are top quality love to all,,,,,,,woodyx
@JRCElectrical
@JRCElectrical 6 месяцев назад
❤️ Thankyou sir you legend
@ningis21
@ningis21 8 месяцев назад
Question.... Now the cables are clipped to the wall studs....and you fix your pattress battens between them and then mount your back boxes on them......doesn't that make all your cable out of zone? especially if the client has it boarded out internally as you mentioned he might do...which will make your cables not comply with BS7671 and the building regs and you have been notified of this prior to starting the electical work????
@JRCElectrical
@JRCElectrical 8 месяцев назад
You could well be right there, depends what they do really, if the building gets battened out to fit the insulation it would need then they would be deeper than 50mm in the wall so it wouldn’t matter anyway, we would have to go back and change the patresses to knock outs anyway before they did anything so I suppose we could change it, out of 55 thousand people to watch the video tho your the only one to say this 👏 fair play
@Burgerboy118
@Burgerboy118 25 дней назад
during lockdown i started living in my friends mancave,its wired up with 2 socket extension fed in from the out house electrics,i would love to put a pay as you go meter to see how much electric i use.
@JRCElectrical
@JRCElectrical 25 дней назад
You could get a ct clamp meter that just goes around the cable or probably get a plug in meter that reads through the 3 pin plug to see what your using
@bullhurley-uv8ys
@bullhurley-uv8ys Год назад
Nice job 👍
@JRCElectrical
@JRCElectrical Год назад
Thank you sir
@Sunny-3
@Sunny-3 Год назад
@JRC Can you please let me know how to work out what armoured cable size is needed?
@JRCElectrical
@JRCElectrical Год назад
The loading of the circuit needs to be worked out and from there can be calculated (power in watts / voltage) that’s the amps needed for the circuit, calculate cable from there
@MrSwevans
@MrSwevans Год назад
Would the 13 amp fuse limit what stuff you could use in the shed, also did you have to use a 3 amp spur for the lights, trying to find out if I can save some money and not have another consumer unit in my garden Room and run armoured cable all the way to the front of the house and just spur off like you guys did here, any advice would be much appreciated 👍
@JRCElectrical
@JRCElectrical Год назад
It would limit what you can use but this one would just be used for charging and other bits like that, to be plugging heaters and things in we would have needed a bigger supply back to the board and a fuseboard in garden room Yeah fuse the lights down
@adamdavis2788
@adamdavis2788 Год назад
For most sheds it people won’t draw more than a couple of amps a larger supply is only really necessary when welders/large tools are being used in the shed. It all depends on what you plan to use now and in the future.
@Hatsan50
@Hatsan50 22 дня назад
Great vid, do you think it would be ok to run a cable from a spare 45amp mcb to a two slot board for lights and sockets to my workshop for power tools.
@JRCElectrical
@JRCElectrical 20 дней назад
Yeah aslong as you supply the right cable to meet the mcb you would be fine
@jdog-ukapprentice7660
@jdog-ukapprentice7660 Год назад
great video lad
@JRCElectrical
@JRCElectrical Год назад
Cheers j dog and welcome back
@Noodles15151
@Noodles15151 Месяц назад
Great video. Looking to do something similar. What's the best way to work out if you'd need a consumer unit or not? I'm looking to turn my small 8x8ft summer house into a studio. Probably two twin sockets either side: one for a desk setup (MacBook/screen/small speakers etc) and another for maybe a TV and Xbox. I have an outdoor socket already coming from an indoor socket. Could I run off that (around 10ft away) or would it be too much daisy-chaining?
@JRCElectrical
@JRCElectrical Месяц назад
If your using it for just that it would be fine run off an outdoor spur next to the double socket i would imagine as long as socket is wired correctly, maybe wire the socket and spur as part of the ring if possible
@stephencarter6634
@stephencarter6634 Год назад
Noice Job lads 👍
@JRCElectrical
@JRCElectrical Год назад
Thanks Stephen appreciate your support 🙏
@woody186294
@woody186294 Год назад
So that house owner now has a non compliant power source to their shed. Not buried at all, 600mm depth is the advice where it likely to be disturbed (it's in a flower bed). Yes it is notifiable for those that asked. No sign of warning tape with is typically about 150mm above the cable but that cable isn't even 150mm deep to start. Under paths patios etc are not likely to be disturbed so far less depth is required. Do not copy that example, or you could end up in trouble.
@adamdavis2788
@adamdavis2788 Год назад
What’s the reg number for this?
@muppit666
@muppit666 6 месяцев назад
And earth rod?
@navitascp
@navitascp Год назад
Very niiiiiice Jack 👍🏽
@JRCElectrical
@JRCElectrical Год назад
Cheers dude
@paulstir
@paulstir Год назад
I want to setup a consumer unit in my shed for running mig welder,small air comp, led light panels and wall sockets for small appliances soldering iron etc what cable should I get ( uk ) ?
@JRCElectrical
@JRCElectrical Год назад
You would have to add up all the loading (wattage) then add a bit more and divide by 230(voltage) this will give you ure max loading and u can spec the cable needed from there
@Jo-NZ522
@Jo-NZ522 7 месяцев назад
Was it a bout powering a shed or was it about you pissing about.
@JRCElectrical
@JRCElectrical 7 месяцев назад
Bit of both 💪
@curiousjoe395
@curiousjoe395 4 месяца назад
Love your videos mate. Great sense of humour. Where else do you find that on RU-vid hey! Would there be any value in a she consumer unit in this scenario? I have an outdoor socket on a 16amp breaker and was planning to spur from there with 2.5mm SWA running down the garden to the shed. It’s around 15 metres. Would appreciate your thoughts on this pal.
@JRCElectrical
@JRCElectrical 4 месяца назад
Cheers dude, if you’re just running a 2.5 down there I wouldn’t install a fuseboard in there, 10mm or 6mm I would install one tho Depends what power you need down there really but just for basic socket for charging batteries or something and lighting it will be fine from 2.5mm
@tullysoutregiusroyals
@tullysoutregiusroyals Год назад
How do you go about this if you have a shed/cabin requiring more power? 10-15 double sockets and lighting (2-3 rings) all To one breaker internal to a shed. Where will this breaker get its electrical feed from? Breaker in the house?
@JRCElectrical
@JRCElectrical Год назад
Would either need a seperate 32/40 amp feed from fuseboard or a sub main going down into the shed/cabin
@paulwrite1405
@paulwrite1405 2 месяца назад
So if the mrs is in the kitchen with the microwave and kettle, extraction fan and the tv on the wall and then I plug in my 110v 3kva transformer to run my makita chopsaw and blue tooth 110 makita extraction hoover and a small fan heater with my batteries for my drills on charge and the lights on and 240v stereo,, are you sure that it wont trip out , cuz I don't want to be walking back and forth into the house to keep flicking up the breaker and then having to keep resetting the time on the microwave and cooker. Or is it better to come from the consumer board on its own 20a circuit. What you think..
@JRCElectrical
@JRCElectrical 2 месяца назад
If your using a lot of power then yeah defo come from the board, if it’s just to charge tools and things then it’s fine, any time heater is mentioned it’s a larger draw so would be better on its own circuit
@dazzauk8334
@dazzauk8334 3 месяца назад
I am after this type of job. I'm in Birmingham to (rubery) . I want power to a shed as I want a 3d printing workshop to work in.
@Palmit_
@Palmit_ Год назад
how to break out 13amp supply to shed? is it as easy as running twin n earth off of an existing plug socket in the house? or do i need to enter the house fuse box and run from there? intention is to have full power available. welders, power tools, microwave oven, kettle, heater etc. Thank for any advice
@JRCElectrical
@JRCElectrical Год назад
You would need a bigger supply for that straight from the fuseboard, 32 or 40amp at least
@Palmit_
@Palmit_ Год назад
hiya. @@JRCElectrical - Your reply is much appreciated. Thank ya. theres no point in doing work twice, get it right first time to meet the need. I'll pay your time and advice forward, so an electrical contractor somewhere has just landed a job. Thanks again. and thanks for the banter and vids too!
@JRCElectrical
@JRCElectrical Год назад
@@Palmit_ no worrries sir thabkyou 👊
@Arachnoid_of_the_underverse
Nice shed, just needs a fridge,TV and a PC job done😅🔝
@JRCElectrical
@JRCElectrical Год назад
I would imagine most of that will move in soon 👀 😂
@johnrichardson4583
@johnrichardson4583 4 месяца назад
What has he insulated his shed with? It looks very neat
@JRCElectrical
@JRCElectrical 4 месяца назад
He hasn’t that’s just breathable membrane, the insulation goes in after that
@malcolmbale9566
@malcolmbale9566 Год назад
What’s the wire stripper you’re using?
@JRCElectrical
@JRCElectrical Год назад
My latest video has links to most the hand tools i use 👍👍
@metrotechguru5863
@metrotechguru5863 Год назад
You lads are just a riot. How do you ever get anything done?
@JRCElectrical
@JRCElectrical Год назад
Off camera it’s all serious heads down 😂😂 Nah it’s defo not 😂 we do graft aswell as having a laugh tho
@richardsheppard5881
@richardsheppard5881 11 месяцев назад
Hi there what cable did you use and size thanks
@JRCElectrical
@JRCElectrical 11 месяцев назад
I can’t 100% remember but if your coming off a spur, depending on length 2.5mm 3 Core will do
@tonysnowdon1633
@tonysnowdon1633 9 месяцев назад
a sparky picking his mess up didn’t think i’d ever see the day
@JRCElectrical
@JRCElectrical 9 месяцев назад
I would say always but it would be a lie 😂😂😂
@aqr7654
@aqr7654 Год назад
Legend
@JRCElectrical
@JRCElectrical Год назад
🤙🤙🤙
@MartinThoward
@MartinThoward Год назад
Nice job lads 👍🏻
@JRCElectrical
@JRCElectrical Год назад
Cheers dude appreciate it
@JUST-UK-JAY
@JUST-UK-JAY Год назад
didn't show any wiring up at all .... dissapointing !
@JUST-UK-JAY
@JUST-UK-JAY Год назад
thanks but I didnt come here for hearts, I came to learn.
@adamdavis2788
@adamdavis2788 Год назад
If you don’t know how to wire something like this up you shouldn’t try to install something like this. Please get a qualified electrician to come and do this job for you as they will do a safe job.
@JUST-UK-JAY
@JUST-UK-JAY Год назад
@@adamdavis2788 cheers for your input
@rickgreaves67
@rickgreaves67 8 месяцев назад
Not a video to learn from really. Try running cables in conduit from a fuse spur. Plenty of them vids about. I was looking for reinforcement on my wiring to the shed, didn't get it from here.
@hazzah785
@hazzah785 5 месяцев назад
might aswell hand you his pay slips then hadn’t he, plus if you don’t have the experience to do a wiring job like this then DONT TRY hire a professional
@paul_my_plumbs_uk
@paul_my_plumbs_uk Год назад
I thought you'd of had a picture of boy band bundy in the van 🤩🤩🤩😂😂😂
@JRCElectrical
@JRCElectrical Год назад
He’s on the mantle piece at home 😂😂
@paul_my_plumbs_uk
@paul_my_plumbs_uk Год назад
@@JRCElectrical best place for him and adam🤣🤣🤣 couple of gargoyles to keep the kids away from the woodburner
@JRCElectrical
@JRCElectrical Год назад
@@paul_my_plumbs_uk 😂😂😂😂😂
@leeguitarmcr
@leeguitarmcr 6 месяцев назад
What did you bring the SWA into for the Shed? Did you gland into something. Cheers.
@JRCElectrical
@JRCElectrical 6 месяцев назад
We normally gland them into a wiska box and then bring the inner core through into whatever we’re terminating to
@bluemoon7378
@bluemoon7378 Год назад
what would something like this cost in manchester?
@JRCElectrical
@JRCElectrical Год назад
No idea mate, try cablesmith electrical or south Manchester electrical I’m sure they will sort you out 👍
@leogames4180
@leogames4180 4 месяца назад
How much does a job like that cost? I’m needing similar in my workshop.
@JRCElectrical
@JRCElectrical 4 месяца назад
Varies on a lot of different things such as power needed, length of run and where the feed can be taken from
@darrenwalker-tw4wv
@darrenwalker-tw4wv 6 месяцев назад
Hi guys, was this a minor works, or EIC?? I'm not part p registered yet, but could say altered so minor, could say new circuit so EIC. Just interested 😜
@JRCElectrical
@JRCElectrical 5 месяцев назад
I wouldn’t say it’s a new circuit because it was fed from ring 👀
@darrenwalker-tw4wv
@darrenwalker-tw4wv 5 месяцев назад
😂just watched again, thanks for the clarification. Great work💪👏👍
@davidreilly1031
@davidreilly1031 4 месяца назад
I wouldn't dream of running anything other than 10mm, youve already said the shed use will evolve. Why fit underrated cable now, then have to re run thicker cable in future? Also are you ducting the cable to give it airspace or buried direct into the soil. And what about a consumer unit in the shed? Are you really spurring off an outside socket which is spured off a house circuit? How about metal clad sockets in the shed at the bare minimum? Where does this installation meet any regs? What the disconnection time?
@JRCElectrical
@JRCElectrical 4 месяца назад
We normally install a bigger cable and fuseboard in outbuildings as you will see on our channel if that’s specified and wanted in there, sometimes it’s not and the customer just wants sockets and or lights, so that’s what we quote for
@seanwalker6878
@seanwalker6878 Год назад
Thought cables had to be buried 600mm deep per regs?
@JRCElectrical
@JRCElectrical Год назад
My understanding is that it has to burried at a depth where it’s not going to be damaged by a shovel, we have ran this around the perimeter of the garden not through the middle so won’t be damaged by a shovel and under the slab it’s under a concrete slab so won’t be damaged, if the slab ever gets lifted you can see the cable is there I could be wrong tho 😂
@woody186294
@woody186294 Год назад
@@JRCElectrical your understanding is wrong, check the regs.
@adamdavis2788
@adamdavis2788 Год назад
Let’s be honest here it’s no different to clipping it to the fence at the back of the flowerbed and that is compliant. It’s an armoured cable, made of correctly on both sides bonded to earth and it’s on an rcd so if you went though the cable it will trip instantly. It’s safer than the spike lighting that you see installed in flowerbeds with flex underground.
@aidanmcculloch9794
@aidanmcculloch9794 5 месяцев назад
How much would it cost roughly to have this job done?
@JRCElectrical
@JRCElectrical 4 месяца назад
There is a lot to take into account when working out a price for this, cable run, length, how much power is needed, where it’s coming from
@bonaminhrasmey42
@bonaminhrasmey42 8 месяцев назад
How do you get the power from.
@JRCElectrical
@JRCElectrical 8 месяцев назад
Off the kitchen sockets circuit
@bonaminhrasmey42
@bonaminhrasmey42 8 месяцев назад
@JRCElectrical , hope that the whole house will still have the power. Lol
@andrewpowell9159
@andrewpowell9159 5 месяцев назад
Golden rule,if your not used to using a shovel it's advisable to piss in the palms of the hands first.FACT ask any paddy 😂
@JRCElectrical
@JRCElectrical 5 месяцев назад
😂😂😂
@Milldog2023
@Milldog2023 10 месяцев назад
hey guys, so im about to have 16x1 shed fitted in garden, i have armored cable, internet cables,camera cables etc etc. what can u sue to run these under the flags, was thinking like a plastic guttering ? i've also a homemade solar system to install .. I'm no builder, or tradesman. But I'd like to do job myself. Got them switch covers, , them orange lightning protection. But before i do the insides, thinking running rubber 2 inch 3 inch pipe with sprinklers on them. Use a rain catchment system, with like CO2 boost like a soda stream. Where does the law stand with electric fences for private use?. but instead of it going around a field, i wire it in between the inner and owta wall. Nothing daft, also thought of doing the floor like a bug zapper, but use one of them timer mi thingy mi bobs, where it knows somebody is there, but i want a 15 second window before arming, So every footstep back would zap the thieves all the way back out of the property lol.
@JRCElectrical
@JRCElectrical 10 месяцев назад
That all sounds fantastic 😂😂😂😂😂😂
@WillmannElectrical
@WillmannElectrical Год назад
big uppppps😂😂
@JRCElectrical
@JRCElectrical Год назад
😎 big up
@ELECTRICLIFE4U
@ELECTRICLIFE4U Год назад
👍👍👍
@JRCElectrical
@JRCElectrical Год назад
👊
@peterigrenyi9176
@peterigrenyi9176 9 месяцев назад
Last power we ran into a garage was in 95mm 5core SWA 😂😂😂
@JRCElectrical
@JRCElectrical 9 месяцев назад
You will struggle to get that into a spur
@peterigrenyi9176
@peterigrenyi9176 9 месяцев назад
@JRCElectrical haha. This is true. But u can always trim the core to fit the terminal I guess 🤔
@JRCElectrical
@JRCElectrical 9 месяцев назад
@@peterigrenyi9176 tis true a 92mm haircut would be fine wouldn’t it 😂😂
@Waynesworldofgaming
@Waynesworldofgaming Год назад
First! Big up JRC!
@JRCElectrical
@JRCElectrical Год назад
Big up you dragon 🐉
@three-phase562
@three-phase562 Год назад
Poor Scotty got bigged up by that pigeon 🤢🤢. Looked like that shed had been lined inside, nice bit of quality.
@JRCElectrical
@JRCElectrical Год назад
Fully bigged up in his mouth 😂😂
@JRCElectrical
@JRCElectrical Год назад
Yeah the shed was sick to be fair floor was mega thick aswell
@1984rbarker
@1984rbarker Год назад
Is this work notifiable?
@JRCElectrical
@JRCElectrical Год назад
I would imagine so as your providing power to an outbuilding
@1984rbarker
@1984rbarker Год назад
@@JRCElectrical Ok so just to clarify...if I put an outdoor socket on the outside of a shed it isn't notifiable as per Part P, but if I put an outdoor socket on the inside of a shed, it is notifiable?
@JRCElectrical
@JRCElectrical Год назад
@@1984rbarker I no they changed it for if your not adding a new circuit but u would be best checking with your governing body 👍
@1984rbarker
@1984rbarker Год назад
I did some research and this work isn't notifiable if you are just extending a circuit.
@cranefamily
@cranefamily Год назад
Jack ever thought of using the PVC back boxes and glanding in to them also less chance of damage for you and them long term just a thought don't unsubscribe me 😂
@JRCElectrical
@JRCElectrical Год назад
There’s lots that could be done differently but to keep the cost down for them that was best 🤷‍♂️ 😂😂😂 Conduit would have been the one but the customer wasn’t sure if there boarding it or anything so didn’t see the point wasting money on it 😂
@pmacc3557
@pmacc3557 Месяц назад
If tge owner wants a second wood chipper iv got one for sale😂
@JRCElectrical
@JRCElectrical Месяц назад
What do you mean?
@pmacc3557
@pmacc3557 Месяц назад
@@JRCElectrical I noticed he has a wood chipper like mine while you were doing the measurements inside
@JRCElectrical
@JRCElectrical Месяц назад
@@pmacc3557 o hahahaha I thort you meant because I was drilling the wood or something 😂😂😂
@pmacc3557
@pmacc3557 Месяц назад
@@JRCElectrical great videos. Can't imagine the time it takes to work but keep in mind you have to record edit sound etc..👍👍
@JRCElectrical
@JRCElectrical Месяц назад
@@pmacc3557 Thankyou sir 🙏 much appreciated
@matthewtucker1178
@matthewtucker1178 Год назад
Get bundy to do it 😂😂👍🏻 and don’t pay him 😂😂
@JRCElectrical
@JRCElectrical Год назад
What do u mean? 😂
@matthewtucker1178
@matthewtucker1178 Год назад
@@JRCElectrical if you didn’t have someone you could used him for your digging work …. O sorry he’s a sparky ! 😂😃
@JRCElectrical
@JRCElectrical Год назад
@@matthewtucker1178 😂😂😂😂
@Langwigcfijul
@Langwigcfijul 3 месяца назад
Yam yam ay ya mate?
@JRCElectrical
@JRCElectrical 3 месяца назад
Ay we
@pagangardener
@pagangardener 5 месяцев назад
Flutes
@richardwilliams6055
@richardwilliams6055 Месяц назад
Not using earthsure twin and earth
@JRCElectrical
@JRCElectrical Месяц назад
I would have but this video is from 2 years ago 😂
@michaeljane6141
@michaeljane6141 Год назад
Yooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
@JRCElectrical
@JRCElectrical Год назад
Yo yo yo 😎
@simonbmr
@simonbmr Год назад
Barely a DIY standard job! Spurred off a socket on the ring?? Plastic surface mount pattresses in a shed??? Cable barely buried and no warning tape??? Embarrassing.
@activateelectrical1720
@activateelectrical1720 Год назад
Agree. Thought it was me. Could have used Metal Clad Wiring Accessories What about TT rod for equipotential zone?
@bullhurley-uv8ys
@bullhurley-uv8ys Год назад
​​​@@activateelectrical1720 TT why? No reason to, it's a wooden shed with no extraneous parts.
@adamdavis2788
@adamdavis2788 Год назад
You both sound like you have never worked a day in real life metal clad would be great to install but I’m sure the client had a budget, same for the fact it is spur of the ring not on its own circuit. Running the cable back to fuse board is preferred but not necessary so he hasn’t done anything wrong here in fact
@Cyberpunk_Banshee
@Cyberpunk_Banshee Год назад
​@@adamdavis2788yup, the fused spur keeps everything from melting, 2.5mm will easily take over 13 amps though so that's not the main worry. The only issue I see with coming off a fused spur is trip times, if the cable run is long then it could do with an earth spike. But if this is a budget install that's not gonna happen.😅
@stevemiller8794
@stevemiller8794 6 месяцев назад
What a load of crap
@JRCElectrical
@JRCElectrical 6 месяцев назад
O
@leeedsonetwo
@leeedsonetwo 20 дней назад
Learned nothing, thanks
@JRCElectrical
@JRCElectrical 20 дней назад
Your welcome
@kylo9928061983
@kylo9928061983 10 месяцев назад
How much cost a putting electricity in this shed?
@JRCElectrical
@JRCElectrical 10 месяцев назад
Depends on a lot of different things
Далее
Plasterboard HACK | Every DIY'er Should Know
11:29
Просмотров 510 тыс.
WARNING: You Might Get Shed Envy
13:13
Просмотров 111 тыс.
How to use a multimeter like a pro, the ultimate guide
12:55
Testing The Burn Ability Of Insulation In Wall
19:45
Просмотров 2,6 млн
How to Run Permanent Temporary Power to a Shed
48:30
Просмотров 890 тыс.
Собираем комп за 500 000 рублей!
6:44:35