Тёмный

TIA Portal: How to use Counters (CTU, CTD, CTUD) 

Hegamurl
Подписаться 79 тыс.
Просмотров 67 тыс.
50% 1

How to implement different counter types in you TIA program?
...what does it all mean and why do you need it?
Find it out here!
If this video helped you, please consider helping me by joining my "GoFundMe" and donating a small amount to my cause. Link here:
www.gofundme.com/f/let039s-fi...

Наука

Опубликовано:

 

20 ноя 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 56   
@Vozzhd
@Vozzhd 4 года назад
The best I've seen of the TIA Portal)) You explain everything easily and clearly. Thanks!
@DomoKrch
@DomoKrch 7 месяцев назад
Your manner of showing things is underrated
@adrianmacovei4990
@adrianmacovei4990 Год назад
You’re the best ! You are amazing in explaining TIA . Thank you !
@nahblaze3419
@nahblaze3419 6 месяцев назад
this man is a w mans don't know if he still post but appreciate the explanation is very clear thank you
@UnitalianoinCina
@UnitalianoinCina 4 года назад
i'm using tia portal after years for an upgrade project at work, i was using TIA v11, now i have v15.1, i can feel the Pc run smoothly than before (the PC is the same), at least TIA doesn't crash often now :D anyway... wonderful videos, i'm following you from a while and i like this channel, Greetings from an Italian guy living in China...
@amolkirad3185
@amolkirad3185 4 года назад
You are doing great job man.....
@adrianl4936
@adrianl4936 4 года назад
Very good explaining as always
@eduardoaleman5290
@eduardoaleman5290 4 года назад
CTUD, I actually found a use for this instruction. I'm using the instruction to simulate the level of a tank 0-100 gallons, the instruction fills the tank and emptiest the tank. I use that on a HMI and you can see how the BAR-graph goes up/down. I'm sure they may be different way to simulate this but I use the CTUD and it work fine. thank you!
@roxterat
@roxterat 4 года назад
CTUD counts by steps, depending on the way you fill/empty the tank, the value may vary from the counter's count unless you also implement comparison/value check, but then it would make counter use obsolete..
@seanyushi9096
@seanyushi9096 2 года назад
@@roxterat 0p
@jamieharbron9576
@jamieharbron9576 Месяц назад
Love your content
@mohamadhady1518
@mohamadhady1518 4 года назад
Thank you for your explanation
@hasanmucuk7852
@hasanmucuk7852 3 года назад
It is very useful video to improve tia
@sarahlabidi6558
@sarahlabidi6558 10 месяцев назад
Great Video sir, thank you .
@thanhvibes
@thanhvibes Год назад
A lot more than I learn in school.
@targus9966
@targus9966 4 года назад
thank you, very helpful !
@ILSCDF
@ILSCDF Год назад
Thanks for doing the job my professor should do
@rominascherrer4399
@rominascherrer4399 3 года назад
great job...thanks!
@Olavotemrazaodenovo
@Olavotemrazaodenovo 4 года назад
Excellent
@natanaelwieland5137
@natanaelwieland5137 8 месяцев назад
great video, keep up the good work. How can i make it, so that the counter just counts how many times the door has been opened without putting in a max value (5), and then flashes a light the amount of times the door has been opened
@sergiumaier3966
@sergiumaier3966 2 года назад
good explanation, ty!
@prasannakottage4575
@prasannakottage4575 3 года назад
Hi , Can you please do a HSC example with single and AB counter.
@moledowhiskey1263
@moledowhiskey1263 2 года назад
Hi, Mr. Hegamurl, I'm an electrical engineering student, and I very much enjoy your educative videos. I'm wondering what your PC specs are to run TIA Portal smoothly like in the video?
@martintrost815
@martintrost815 3 года назад
Dear Philip, I am willing to know if there is any video about High speed Counter. Has it been uploaded by you???
@jdmkoo1161
@jdmkoo1161 2 года назад
what is better, use counter instruction or ADD and Positive edge for +1 to DB record
@chrisgamingmp1806
@chrisgamingmp1806 3 года назад
Thank you !
@joymohadani9366
@joymohadani9366 4 года назад
Please make a video on high speed counter.. Pls with example programming
@gtag174
@gtag174 Год назад
Heya How do you limit the CV from exceeding PV ?
@MADmax-hc8hc
@MADmax-hc8hc 3 месяца назад
Hello . I insert some object like button in jpg format to hmi screen but the event option for them isnt avilable
@satya1027
@satya1027 2 года назад
If plc power fail is the counter reset to zero ? And one more thing how to configure alarm that plc power failure occur
@ATOMACH
@ATOMACH 3 года назад
Thank you !!!
@nothink1314
@nothink1314 3 года назад
thank you so much
@hasanmucuk7852
@hasanmucuk7852 3 года назад
My tia portal app is so slow for simulation. How can ı getting faster it?
@wailinoooo8564
@wailinoooo8564 4 года назад
Hi Hegamurl, Do you have any online training Course?
@animatsioningliztili3003
@animatsioningliztili3003 3 года назад
what software did you use for HMI?
@uditsaxena3844
@uditsaxena3844 10 месяцев назад
Thanks
@ankurkumar15188
@ankurkumar15188 4 года назад
How to make Totalizer using Flow meter
@yasinjibet72
@yasinjibet72 3 года назад
merci tu geres
@johannesschweinberger4877
@johannesschweinberger4877 4 года назад
TIA Tuersday !!!
@korabhyseni
@korabhyseni 3 года назад
very good explain, but i didnt unterstand how did you make The value_reached. could you explain me please thank you .. you were perfekt
@satya1027
@satya1027 2 года назад
By make click in HMI button which is link to NO contact of that program
@anoop22march
@anoop22march 4 года назад
Great Video sir, thank you . Sir when we get video on HSC Configuration, hardware connection. Waiting for your reply.
@tylkonareklamy
@tylkonareklamy 3 года назад
Another great movie. This time there is a small mistake ... 10:30 - The door opened for the sixth time and then it closed very quickly ... ;)
@MrZitrex
@MrZitrex 4 года назад
Hallo, do you plan on doing PID in TIA in near future?
@mortenlund1418
@mortenlund1418 4 года назад
Please look at previous videos. Her is some perfect explanaitions. Best wishes.
@hegamurl7434
@hegamurl7434 4 года назад
Exactly as Morten said😁
@abdulsamathu88
@abdulsamathu88 4 года назад
nice................... one doubt hega..........how to do door open/close in hmi.
@satya1027
@satya1027 2 года назад
Y know how to open the door for preset value same thing for door close that graphics built by hema for Understanding only we can take any other example
@lamoule74
@lamoule74 3 года назад
An int can provide 65536 counts, from -32768 to 32767 i.e. coded on 16bit
@hegamurl7434
@hegamurl7434 3 года назад
That is correct, yes. Did I say something else in the video? Can not remember^^
@lamoule74
@lamoule74 3 года назад
@@hegamurl7434 you hesitate a bit on the value, so to avoid any questions about it I permit myself to bring few infos, sorry, I did it with kindness for you community. Cheers.
@hegamurl7434
@hegamurl7434 3 года назад
@@lamoule74 perfectly fine! Thanks for the assist! I never remember the correct numbers, just the 2^16... that is usually enough 😅
@lamoule74
@lamoule74 3 года назад
@@hegamurl7434 haha, no kidding? 😂I ensure you me neither for the 32767, but 65536 is ok, it sounds easier for me (in Fr) no explenation, well anyway...
@altemir2
@altemir2 Год назад
Der automatische Untertitel des Videos ist nur auf Englisch, könnten Sie den automatischen Untertitel auf Portugiesisch hinzufügen? Vielen Dank.
@antonhofreiter787
@antonhofreiter787 5 месяцев назад
Man merkt den deutschen Akzent 😂
@rajeevkr.4185
@rajeevkr.4185 4 года назад
Thanks
Далее
skibidi toilet multiverse 039 (part 4)
06:06
Просмотров 3,4 млн
Stay on your way 🛤️✨
00:34
Просмотров 5 млн
Studio 5000 CTU CTD Counter Explained
15:21
Просмотров 18 тыс.
TIA Portal: Analog Processing / NORM_X and SCALE_X
25:29
TIA Portal: How to use Timers (TON, TOF, TP, TONR)
15:32
TIA PORTAL Session # 5 How to use counter ?
5:37
Просмотров 8 тыс.
TIA Portal: HMI Easy Alarms
18:20
Просмотров 144 тыс.
TIA Portal: IO-Devices / PLC-PLC Communication
15:47
Просмотров 105 тыс.
iPhone, Galaxy или Pixel? 😎
0:16
Просмотров 1,1 млн