Тёмный

Totaline/ICM controls head pressure control installation 

Michigan Heating Guy
Подписаться 20 тыс.
Просмотров 21 тыс.
50% 1

Totaline head pressure control instullation
www.amazon.com...
ICM Controls ICM325HN Low Ambient Head Pressure Control, Output 120-480 VAC, Temperature Input
amzn.to/2Eo6uAV www.amazon.com/shop/miheatingguy
Milwaukee 2131-20 M18 ROCKET Dual Power Tower Light
amzn.to/3pe2hYH
Milwaukee M12 Surge Hydraulic Driver Kit 2551-22
amzn.to/3n5offb
Makita E-01563 Impact XPS 3 Pc. 6" Magnetic Nut setter Set
amzn.to/2JdAcku
Milwaukee 48-22-6330 Tongue and Groove Pliers Set
amzn.to/3kfch0R
GoPro Hero 8 Black Action Camera with Accessory Bundle
amzn.to/34AGamf
Veto Pro Pac Tech XL Tool Bag
amzn.to/2U1QqPF
OLIGHT Bundle H2R LED Headlamp, 2300 Lumens Rechargeable Flashlight
amzn.to/370rGiq
Amprobe AMP-320 Clamp Meter
amzn.to/2GNxUHe
Fluke 117 Electricians True RMS Multimeter
amzn.to/3iFZP9t
Milwaukee 2364-20 M12 Rover
amzn.to/2HNvitK
Milwaukee Rocket light 2132-20
amzn.to/341OTPm
#MIHeatingGuy

Опубликовано:

 

10 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 49   
@Dicktoben
@Dicktoben 4 года назад
Thanks. I’ve got a grow op to get running with a couple of these tomorrow. I don’t see them very often
@juanmarte9295
@juanmarte9295 3 года назад
Thank you Thatcher from dominic republic
@hvac01453
@hvac01453 6 лет назад
good video.... Those are ICM head pressure controllers. They also make one with its own transformer. They also make a separate one for heat pumps too!
@NorCal-refrigeration
@NorCal-refrigeration 6 лет назад
We use those all the time here. 👍
@hvac01453
@hvac01453 6 лет назад
on new installs, Trane make a special motor for this expressed purpose. They call it a low ambient kit and includes a CCH.
@TomokoAbe_
@TomokoAbe_ 6 лет назад
i'm going to get one of those. Thanks for the video I did not even know they existed!
@RineboBohead
@RineboBohead 4 года назад
Thank you for the pointers!
@polishtheturdmickelson5473
@polishtheturdmickelson5473 6 лет назад
Nice setup, rather than installing a swivel tee and have to worry about it leaking down the road. Especially on a 410 A system.
@timothymyers3072
@timothymyers3072 5 лет назад
Right. I have Roof Top A/C unit for a PD Server Room have that problem. First the Swivel Tee leaked so I Brazed a Tee in, then months later the Pressure Switch leaked. Now I'm finally going to install one of these.
@RobHVAC
@RobHVAC 6 лет назад
Yep I like those also.
@buffordbaxter3370
@buffordbaxter3370 4 года назад
Great Video! I’m a service tech in Battle Creek, MI
@alamirahmad3169
@alamirahmad3169 16 дней назад
why do you like to do it on temperature ?
@rookierefrigeration4357
@rookierefrigeration4357 5 лет назад
Great video. Thanks for sharing
@damarcojackson1005
@damarcojackson1005 5 лет назад
That is bad ass .... !!! I love it 👍
@minhngo764
@minhngo764 2 года назад
Very nice video! Thank you! How can you tell if the motor is ball or sleeve bearing to set the cutout speed and so?
@albertoarballo9507
@albertoarballo9507 4 года назад
Thanks for the video!!
@tylercarver7924
@tylercarver7924 5 лет назад
Looking at schematic, shouldn't the wires go on the line side of the contactor?
@jonnymac31
@jonnymac31 6 лет назад
Guys say they are hard on motors because of the higher amp draw during low ambient. I also like that control. Hoffman had the market before they let ICM crash the party.
@minnesotasalamander5913
@minnesotasalamander5913 6 лет назад
Seems like the amps would go up when motor slows down.
@Corvette-nz8wb
@Corvette-nz8wb 4 года назад
What is the proper setting on each of the RED knobs? My unit did not come with instructions.
@avaairheatingcoolingllp3115
@avaairheatingcoolingllp3115 4 года назад
Nice. Thanks.
@eddiesellers8522
@eddiesellers8522 6 лет назад
Again. What did you put your settings at again? I understand the sleeve barring at 100% what was the other?
@mikestoll2328
@mikestoll2328 5 лет назад
Can you use 1 on 2 condenser motor 7 ton unit or do you need 2 individual head pressure units?
@sandmanx4733
@sandmanx4733 6 лет назад
Nice
@alessichris07
@alessichris07 6 лет назад
Because it’s a heat pump you got 24 volts to power defrost board. If it was a straight cool unit, i guess u would power the device off the Y or cool wire?
@leifhoganson6996
@leifhoganson6996 6 лет назад
Chris Alessi that's not a heat pump it has a phase monitor on it.
@trinito97
@trinito97 3 года назад
34 degrees and they need ac?
@natehicks8939
@natehicks8939 5 лет назад
ICM is what you’re trying to think of?
@joeshearer1247
@joeshearer1247 6 лет назад
Do you have a ball bearing motor at home?
@MiHeatingGuy
@MiHeatingGuy 6 лет назад
No
@Guyhakverdi
@Guyhakverdi 6 лет назад
What is that control board next to totaline?
@MiHeatingGuy
@MiHeatingGuy 6 лет назад
Phase monitor
@gmguy156
@gmguy156 6 лет назад
Its basically an ICM control with a totaline label
@throttlebottle5906
@throttlebottle5906 6 лет назад
seems that way...
@tjbee1905
@tjbee1905 2 года назад
3 phase unit???
@MiHeatingGuy
@MiHeatingGuy 2 года назад
No
@hvac01453
@hvac01453 6 лет назад
On and off beats up a motor just like they others do so either one will wear the motor out a bit early.Unless you run the cooling during cool weather, we don't use em.
@throttlebottle5906
@throttlebottle5906 6 лет назад
it's all chinesium garbagey anyways :))
@hvac01453
@hvac01453 6 лет назад
That’s what we use to say about made in Japan. What do you think about Japaneese quality nowadays???
@throttlebottle5906
@throttlebottle5906 6 лет назад
yeah, but china has had 10x+ the time to start producing better things, yet their still busy not paying the slave children to make things
@hvac01453
@hvac01453 6 лет назад
underpaying labor is one thing, poor quality is another. They just have to get to that point where the government mandates quality. Chineese could do this overnight. Their penalties are over the top, but maybe thats what it takes to get the point across.....
@alessichris07
@alessichris07 6 лет назад
I guess it cycles fan in heat mode on heat pump too? I am confused how it knows if its in heat or cool on heat pump?
@MiHeatingGuy
@MiHeatingGuy 6 лет назад
This is a straight cool unit you can use it for a heat pump it does have a heat pump jumper So in the winner the fan stays on
@alessichris07
@alessichris07 6 лет назад
Mi Heating Guy Cool thats a pretty handy device. I seen that little circuit board in video and thought it was a defrost board. Thanks for the video, i am going to try and put one on the van. 👍🏻👍🏻👍🏻👍🏻👍🏻👍🏻
@MiHeatingGuy
@MiHeatingGuy 6 лет назад
Chris Alessi That's carriers phase monitor board
@throttlebottle5906
@throttlebottle5906 6 лет назад
what kind of third world country do we live in? brownouts/phase drops lol!
@Barracuda48082
@Barracuda48082 4 года назад
Check rotation..
@hvacr24
@hvacr24 6 лет назад
Capacitor dead give away on 1 phase cond fan mtr
@hvacr24
@hvacr24 6 лет назад
You dont need capacitors when you have three phase motors.. 3 different sine waves... I love this video
Далее
Carrier Winter Start Kit And Head Pressure Control
40:26
ICM325A Universal Head Pressure Control (Install)
8:51
Они захватят этот мир🗿
00:48
Просмотров 761 тыс.
HVAC 107 Scenario: Low Ambient
11:40
Просмотров 11 тыс.
How To Quiet Your AC to Normal Conversation Volume
11:08
Online HVAC Training - HVAC Training  Solutions -
7:44
Просмотров 228 тыс.