Transient Thermal Analysis using Hypermesh [Optistruct Tutorial] 

Aeroswap
Подписаться 9 тыс.
Просмотров 7 тыс.
50% 1

Опубликовано:

 

19 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 69   
@muhammadaliabid5793
@muhammadaliabid5793 3 года назад
another amazing tutorial! Cannot be created better than this hats off!
@Aeroswap
@Aeroswap 3 года назад
Thank you :)
@donotopen6597
@donotopen6597 3 года назад
Been waiting for this. Thankyou.
@dhruvdroids
@dhruvdroids Год назад
Thanks bro. Helped me brush up thermals
@emmanuelvassilakis5630
@emmanuelvassilakis5630 3 года назад
First comment! Nice work Swapnil, Excellent presentation of transient thermal analysis. Btw: How do you change the "D" value on an already defined spc_temp? Thanks!
@Aeroswap
@Aeroswap 3 года назад
Thanks Emmanuel :) For that you can use the card edit option. Set the entity selector to 'Loads' and select that spc. Then you can edit the card and change D value.
@emmanuelvassilakis5630
@emmanuelvassilakis5630 3 года назад
@@Aeroswap Thanks for the reply Swapnil
@hristijanmazganski7102
@hristijanmazganski7102 2 года назад
Maybe CFD Tutorial for Pump will be useful for us too :) BTW thanks @aeroswap for tutorials, great job
@adibadzaman3501
@adibadzaman3501 3 года назад
nice video. can you make a tutorial on thermal analysis of resistance spot welding using Optistruct? hope to see more tutorial from you
@Aeroswap
@Aeroswap 3 года назад
Thanks for the suggestion. I will work on this topic soon!
@bilalqureshi941
@bilalqureshi941 2 года назад
In card image, There's no TLOAD1. And some other cards are also missing like slave1/2 Please help how can i enable them!!
@Aeroswap
@Aeroswap 2 года назад
Hi Bilal, make sure that you are using the Optistruct interface of Hypermesh. You will not find these options in any other solver interface.
@stanislavsidnei1055
@stanislavsidnei1055 8 месяцев назад
Good health, please tell me how to open RTH files. I’m interested in how the temperature is distributed over the cross section regardless of time, namely over the cross section, that is, the coordinate points of the surface of the part
@adibadzaman3501
@adibadzaman3501 3 года назад
i have question, for the ambient temp node, why you place the node there? or is it can be place anywhere near the model?
@Aeroswap
@Aeroswap 3 года назад
Hi Adib, The ambient node can be placed anywhere in the model. It's location does not affect the analysis. The only reason why I created it near the pipe is because it was easy to extract the center node.
@adibadzaman3501
@adibadzaman3501 3 года назад
@@Aeroswap i see. got it thank you sir
@Eng_mec_JD
@Eng_mec_JD Год назад
There is no TABLED1 option on curves... i have just LINEAR option. I'm using the 2019 hypermesh version
@mohdzavi5895
@mohdzavi5895 3 года назад
Please make a video of Fatigue analysis of an engine block (E N Strain Life Method) using FPM in Hypermesh.
@Aeroswap
@Aeroswap 3 года назад
Thanks for the suggestion. I will work on this topic soon.
@zeeshansayed204
@zeeshansayed204 6 месяцев назад
7:07 why did you gave 85 degrees was that in problem statement?
@onkarjalkotkar5647
@onkarjalkotkar5647 3 года назад
TEMPD card image is used maximum time in thermal analysis. But I didn't know when to use it, could you tell me?
@Aeroswap
@Aeroswap 3 года назад
Hi Onkar, TEMPD defines reference temperature in a thermal analysis. It is used to specify the temperature units (usually Kelvin or degC). As Hypermesh is a unit neutral evnironment, TEMPD provides a base point for the temperature range.
@VishalSelvamani-r2i
@VishalSelvamani-r2i 7 месяцев назад
can you make the same video with the new software 2023 version
@ashishdevasia7944
@ashishdevasia7944 3 года назад
please make a video on Transient Structural Analysis
@Aeroswap
@Aeroswap 3 года назад
Hi Ashish, A detailed tutorial about transient structural analysis has already been posted. You can find it in the 'Optistruct Tutorials' playlist of this channel.
@shashwatnaik9523
@shashwatnaik9523 3 года назад
I have a question, in SPCD why we have used multiplier value as 1? what does it signifies? Thank you and looking forward to your reply
@Aeroswap
@Aeroswap 3 года назад
Hi Shashwat, 1 is the scale factor for SPCD. It signifies how much temperature will be applied at the location. If you enter it as 0, you will not get any temperature rise and if you enter it more than 1, you will get a greater temperature rise than shown in this tutorial. I hope this clears your doubt!
@shashwatnaik9523
@shashwatnaik9523 3 года назад
@@Aeroswap Thank you for the reply....got it👍🙌
@saivijay5626
@saivijay5626 3 года назад
if i use temp of 2000 degrees in spc_temp and spcd_temp as d=1, And in case of spc_ambient as 25 degrees and spcd_ambient as 1. i got my results with error and in my problem i need 2000 degrees temp and 25 degrees ambient temp shouldbe taken. help with this
@muhammadaliabid5793
@muhammadaliabid5793 3 года назад
Dear Swapnil! One question please:- You clicked conv_cont while performing Engine Block coupled thermal stress analysis tutorial but not this time! Can you explain what is conv_cont while linking convection interface to ambient temp. please?
@Aeroswap
@Aeroswap 3 года назад
Hi Ali, It is just a part of creating Hypermesh comments for a specific card (This helps in solver deck export operations). It does not affect the analysis results in any way. You can simply skip that step and complete any thermal analysis setup! I hope this information helps :)
@muhammadaliabid5793
@muhammadaliabid5793 3 года назад
@@Aeroswap Thank you for this explanation. I understood now
@anilkonderu848
@anilkonderu848 3 года назад
Can you please tell me how to apply thermal gradient loads for shell elements. Like different temperatures for top fiber and bottom fiber of shell element
@Aeroswap
@Aeroswap 3 года назад
Hi Anil, Shell elements have constant parameters in thickness direction. Hence it is not possible to apply different temperature on sides of the same shell element. To do this, please use brick (hexa-penta) elements.
@RamyaM-wx5xe
@RamyaM-wx5xe 6 месяцев назад
Hello Sir Im Unable to edit material properties how to resolve this
@vinodraj60
@vinodraj60 3 года назад
@aeroswap Hi Guys ! have you posted any videos for fatigue ?
@Aeroswap
@Aeroswap 3 года назад
Not yet. I am working on a fatigue analysis tutorial. Hopefully, it will be posted soon!
@chinguyenphung4671
@chinguyenphung4671 2 года назад
hi sir in the load step ( analysis type , heat transfer ) i dont have the IC why ????
@Aeroswap
@Aeroswap 2 года назад
You need to use analysis type as 'Heat transfer transient'. IC will not be available in 'Heat transfer steady state'.
@saikumarmadala2793
@saikumarmadala2793 3 года назад
Hi sir, without linking 3 or more materials with each other for a component in one bulk entry data and keeping each material in one subcase, can we perform a static or thermal or any other analysis and displaying the results for each case(i.e for each material) and by keeping the load collectors for all materials as same. It is possible?
@Aeroswap
@Aeroswap 3 года назад
Yes, but you can assign only one material to each component. Therefore, you will have to create separate FEM files if you want to test a particular component with different materials.
@saikumarmadala2793
@saikumarmadala2793 3 года назад
@@Aeroswap Thank you sir
@saivijay5626
@saivijay5626 3 года назад
bro make a video Axisymmetry using Linear Static Analysis
@Aeroswap
@Aeroswap 3 года назад
Thanks for the suggestion. I will work on this topic soon!
@yatikshah4255
@yatikshah4255 2 года назад
sir, while importing this geometry error is coming the file specified is not a hypermesh database
@saimadhav7604
@saimadhav7604 3 года назад
Hello, Iam trying to important stp file in hypermesh. while importing the file iam facing error, called "segmentation error". Please help me to solve this problem
@saimadhav7604
@saimadhav7604 3 года назад
This is stp file once check bro
@Aeroswap
@Aeroswap 3 года назад
Please make sure that all import settings are kept on their default values. The default setting work best for STEP/STP import.
@saimadhav7604
@saimadhav7604 3 года назад
I imported by default only in stp so. I got this "segmentation error"
@gurbakshsingh152
@gurbakshsingh152 3 года назад
Bro, do you know how we can allocate more RAM and CPU to make the HyperMesh Analysis run fast? Because I have access to High Performance Computer which has 32 CPU's and 128GB RAM. Thanks and looking forwards to your reply soon.
@Aeroswap
@Aeroswap 3 года назад
Hi Gurbaksh, You use multiple cores to run an analysis faster. This can be done by specifying the below command in options field before launching the solver- "-nt " I hope this helps!
@gurbakshsingh152
@gurbakshsingh152 3 года назад
@@Aeroswap There is already a command written by default in the options box "-optskip". Should I erase this and then input "-nt" ? or Should I put "-optskip, -nt" ?
@Aeroswap
@Aeroswap 3 года назад
-optiskip means the solver will perform the analysis and skip the optimization. As this is just an analysis and not optimization, you can keep it or erase it. Both is okay.
@gurbakshsingh152
@gurbakshsingh152 3 года назад
@@Aeroswap Thanks for letting me know what -optiskip means, I wasn't aware before. But unfortunately, when I am giving it a go I am not getting the .mvw file which I usually use to get. Also, I am not able to see the HyperMesh Analysis Progress window while following this approach.
@Aeroswap
@Aeroswap 3 года назад
Alright. Try entering '-analysis' and run again. See how it goes!
@atharvakate5165
@atharvakate5165 3 года назад
I saw your composite tutorial but can u make another one with a more complicated structure .......is there anyway I can contact u ?
@Aeroswap
@Aeroswap 3 года назад
Hi Atharva, My email address is given in the 'About' section of this channel. Feel free to contact me via email. Thanks.
@atharvakate5165
@atharvakate5165 3 года назад
@@Aeroswap what can we do to see flux and temperature gradient ??
@Aeroswap
@Aeroswap 3 года назад
This can be done by selecting 'Flux' option in global output request card.
@tuanvan4624
@tuanvan4624 3 года назад
Hi sir i'm using hyperworks 2019, I did as you instructed but i got an error '' *** See next message about line 182288 from file: D:/hyperwork/OptiStruct/heat_themal/transient_themal.fem "DLOAD 10 1.0 8 1.0 9" *** ERROR # 1000 *** in the input data: Incorrect data in field # 3.'' can you help me explain this error? thank sir
@Aeroswap
@Aeroswap 3 года назад
Hi Tuan, Looks like you have missed out on some step in the setup process. Please watch the tutorial carefully and follow every step. It will resolve the error.
@tuanvan4624
@tuanvan4624 3 года назад
Hi sir, I watched it and did it again but it still have the same error as above. Can i give you my file to you check this error ? thanks sir
@Aeroswap
@Aeroswap 3 года назад
Check your DLOAD card. Make sure that S field is set to 1.
@tuanvan4624
@tuanvan4624 3 года назад
@@Aeroswap yes sir field S is 1
@Aeroswap
@Aeroswap 3 года назад
The error message states that something is not correctly defined in the DLOAD. Please check all scale factor values. Also check whether you have assigned the DLOAD in correct field in the loadstep.
Далее
Thermal Analysis Hypermesh CAE
24:55
Просмотров 9 тыс.
Modal Analysis using Hypermesh [Optistruct Tutorial]
16:26
What La Niña Will do to Earth in 2025
19:03
Просмотров 533 тыс.
Understanding Resonance Mode Shapes
4:47
Просмотров 164 тыс.