True chefs drawers cooler - can we fix it?!? 

Restaurant Repairs
Подписаться 6 тыс.
Просмотров 962
50% 1

Опубликовано:

 

27 июн 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 24   
@harrydickson4575
@harrydickson4575 Месяц назад
Those Chef bases are the worst. You’re on point when you said it’s done. 👍👍👍
@restaurantrepairs
@restaurantrepairs Месяц назад
It’s funny the split on here. Some guys are legit like “new cap tube new dryer she’s good” and others are like no way she’s done…. It’s really interesting to talk thru with everybody.
@harrydickson4575
@harrydickson4575 Месяц назад
@@restaurantrepairs exactly there is a split but for me personally it’s not worth my time or the customers money, repairing an old unit which may or may not work properly,
@philltafolla
@philltafolla Месяц назад
I would quote them : New compressor , new drier , replace the cap tube with a txv , no more restrictions🤷🏻‍♂️
@WswRefrigeration
@WswRefrigeration Месяц назад
Best bet is to obviously replace the cap tube (fyi 90% of true 1/3hp units are either .046 or .049 10-12 feet I stock both those sizes (supco sells them both in 11-12 ft lengths. 15-20$) Or supco bc2 universal cap tube Best bet to clearing it out is back blowing it ( unbrazing or cutting suction line, brazing on a port and back blowing through the evap out the cap tube but even that’s a 50% chance and it’ll clog again in a few weeks
@jvcajw1
@jvcajw1 Месяц назад
Like playing in a cardboard box on Christmas day! LOL. Just a box that smells like old food... LOL. Wow! heating the cap tube up? Nice try. I would have just replaced the cap tube and dryer. Seems the time you spent doing the heating cap tube attempt. You could have replaced the cap tube and dryer... Looks like a new compressor. That's good. For a few $100 more, I like to replace the Evap coil. Then all the "inside" coil/tube issues are covered.
@timsky99
@timsky99 Месяц назад
I hate capillary systems, it's usually some rotten, unloved filthy old fridge that needs hours of work and you may or may not be able to fix it. You get it going then it blocks again and you're trying to get paid for not repairing something....give me a TXV any day.
@life_behind_bars
@life_behind_bars Месяц назад
Whenever I get a restricted R134A system, I recover the refrigerant, pull out the filter drier, and flush the cap tube and both coils with RX11 and nitrogen. I drop in a new filter drier, pull a deep vacuum, and recharge. Sometimes it works, and sometimes it doesn't, but I always make sure the customer knows the risk. I definitely agree with you on th 50/50 odds.
@restaurantrepairs
@restaurantrepairs Месяц назад
Right, and if it does work maybe in 6 weeks when it’s restricted again they have a sour taste in their mouth about the bill for the “failed” repair even thought they understood up front.
@restaurantrepairs
@restaurantrepairs Месяц назад
I’d rather them be frustrated I won’t attempt a fix and use someone else then be frustrated at me for constantly trying to fix it and failing.
@life_behind_bars
@life_behind_bars Месяц назад
@restaurantrepairs oh I'm with you on that. I give them the option with a big disclaimer. I've gotten better at telling them I won't even try. Over heated units running R134A is a disaster waiting to happen. Haven't had this issue with R290 yet.
@bensreferigeration
@bensreferigeration Месяц назад
Dude, just drop some supco 88 in there.... "prevents call backs" 😂
@armandotorres626
@armandotorres626 Месяц назад
Went from bad to worse 😅.... I hate those low boy/cook drawer units with a passion....
@justanoldhandyman
@justanoldhandyman Месяц назад
You tried. Thanks for sharing.👍
@raviyadav8743
@raviyadav8743 Месяц назад
True still stuck on old control system, 😅😅
@user-de3cm9lf8o
@user-de3cm9lf8o Месяц назад
I’m wondering if a vacuum and maybe a little map gas would have had a better effect. Simply because you’re going to need a vacuum before you charge it after you find the leak …..
@restaurantrepairs
@restaurantrepairs Месяц назад
The thing is that system is likely top to bottom so infected that obviously I cleared it some then not, then yes, then not. My heart shatters with calls like this. I wanna be the hero, I want for make a way, but the likelyhood of even a new cap tube and dryer becoming restricted In the mint following a replacement is very high. Then it’s callback after callback and replacing the unit anyway 🪦
@KyleWithStyle7
@KyleWithStyle7 Месяц назад
Wax build up in the cap tube? What could cause that wax?
@restaurantrepairs
@restaurantrepairs Месяц назад
Systems overheat - material breakdowns start. System oil becomes acidic and start tearing apart the coating in the compressor windings - poof - wax.
@KyleWithStyle7
@KyleWithStyle7 Месяц назад
Thank you for the explanation!
@alejandrozometa1951
@alejandrozometa1951 Месяц назад
So do you sell them a new unit
@restaurantrepairs
@restaurantrepairs Месяц назад
I won’t quote a partial repair. I’ll explain honestly that I won’t play repair roulette with that thing. We can replace the entire condensing unit and evaporator coil ensuring the old refrigerant system is COMPLETELY replaced in the old equipment body, they can replace the whole unit, or call a different service company who’s willing to replace the parts and respond every few months when it continues to be problematic.
@shaboomhabaaz8660
@shaboomhabaaz8660 Месяц назад
Cap tube is 20$ at united. Probably a BC 2 or 3. Easy swap dude. Done so many it don't phase me no more. Easy claps 24/7 so easy especially on that model I carry BC1-3 on my van
@restaurantrepairs
@restaurantrepairs Месяц назад
Doing it isn’t the problem, it’s that unlike your experiences half the time it need replacing for me they were back to problematic within a few months. I have had some success but it’s not worth the repair roulette for me. That thing has a fairly new compressor.. why? Cuz the old one windings went bad and corrupted the system maybe, Doesn’t look like a new dryer tho does it? Someone swapped a compressor and left a poisoned system behind. Not this guy. They can get mad at me, I really want to be the guy who fixes it, but I’ll end up being the guy every few months being expected to warranty it.. nah
Далее
SOMEONE MESSED UP BIG TIME
28:20
Просмотров 87 тыс.
How to find a refrigerant leak in an air conditioner?
14:19
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Here is the proof that AMD hates you
15:36
Просмотров 89 тыс.
You're wasting money on heating! Use your A/C!
17:11
Просмотров 439 тыс.
Service Call: Following another company!
35:09
Просмотров 21 тыс.
4090 Graphic Cards are still a Problem.
16:24
Просмотров 99 тыс.
IT'S 107 DEGREES OUT AND THE KITCHEN AC IS NOT WORKING
19:54
Gli occhiali da sole non mi hanno coperto! 😎
00:13