We got called in to fix a problem with a customer's hot water taking forever to reach her kitchen faucet. Mike knew just how to fix it!
Please subscribe and comment below. Contact us at mackinandsonsplumbing.com for scheduling and estimates on your current project!

Опубликовано:

 

7 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 46   
@bigdog8008
@bigdog8008 9 месяцев назад
I have had a gravity system for about 15 years - I love it. Had a 70ft run to master shower and it took forever to heat up. Now always ready and only need to worry about the final couple feet in the line to heat up. He doesn't go into much detail but you must have the recirculation pipe constantly sloped downwards from the far end toward the water heater with no rises in the pipe.
@toddbellows5282
@toddbellows5282 6 месяцев назад
Nothing I like more than watching water run for over a minute.
@tommason4702
@tommason4702 2 года назад
I have a recirculating pump installed in my two story house. After about 20 years, the pump stopped working. So I replaced with another one but it failed after 1 year but somehow I continued to get hot water right away and I did not know how. Anyway I ordered new expensive pump made with stainless steel this time but had to wait almost a week to get it. In the meantime, I took out the broken pump and connected the line without the pump. Sure enough I got hot water right away again as if I have the pump running. I was wondering how this could happen and your video answered what I needed to know. Thanks a lot! It seems like I can do without the troublesome pump and all the work involved in installing it. So I am going to cancel the order. Hooray!!!
@pjmazar4533
@pjmazar4533 5 месяцев назад
Thanks for posting the video and glad it works for you. I had tried this method but found the temperature of the water at the faucet was lower because it is now having equal pressure from the top and bottom, (cold water) of the tank. I modified a ball type check valve by removing the spring and letting the ball float. When pressure is applied, the ball closes off the return line and only uses the hot water line for supply. I've used this system for myself as well as several client's many years ago. I now find that check valve is no longer available. I think a more detailed study would also have to be done comparing the energy needed to continuously heat water in recirculation versus the cost of water being wasted. I think there are too many variables to accurately determine that but for the convenience of nearly instant hot water it is well worth it.
@junkmail4613
@junkmail4613 2 года назад
What about all the heat wasted keeping that hot water loop hot all the time 24 hours a day 7 days a week? You should first calculate how much heat loss there is. then insulate the loop to save heat, but then the whole loop runs hotter, and ya lose the thermal gradient motivating flow through the loop, gotta then add a small circulation pump, then pay electric, repair, and maintenance.
@wadsworthplumbers
@wadsworthplumbers 2 года назад
Most of our customers find the heat loss is minimal and the benefit of a maintenance free system is worth it.
@jackt6112
@jackt6112 7 месяцев назад
Exactly! Gas hot water heaters cost little to run but are inefficient. Electric hot water heaters are efficient but cost a lot to run. People water their lawns all summer long, do laundry, showers, and one flush of the toilet takes more than that. In the summer it works against your air conditioning. So let's be honest. The ONLY reason to have a hot water loop is because it's a pain in the neck waiting that long for hot water, and the temperature at which he terminated the first test was at less than body temperature, which means the person at the faucet would still be waiting well past 50 some seconds and your time is valuable too.
@thedavesofourlives1
@thedavesofourlives1 3 года назад
on an ELECTRIC tank? That must be costing the customer a fortune in electricity costs! If the home had GAS water heat and GAS furnace, any losses would cost the same as running the furnace (except in summer).
@wadsworthplumbers
@wadsworthplumbers 2 года назад
No really because the return temperature isn't that much lower so the heater doesn't have to heat the water up too often.
@mikefa5891
@mikefa5891 2 года назад
You may save a 3-5 gallons of water each day at the kitchen sink, but won;t your electric bill go sky high to keep that water line hot all the time?
@wadsworthplumbers
@wadsworthplumbers 2 года назад
No, because the water coming back into the tank doesn't have to be re-heated much. It only comes back slightly less hot.
@mikefa5891
@mikefa5891 2 года назад
@@wadsworthplumbers But the pump is working 24/7 to keep the hot water fresh in the hot water lines, so even if nobody is using the kitchen faucet, the pump is working to keep fresh hot water in the hot water line 24/7 - surely your electric bill must have gone up since the pump has been installed?
@SergioSalvi
@SergioSalvi Год назад
@@mikefa5891 there's NO pump in this setup.
@mikefa5891
@mikefa5891 Год назад
@@SergioSalvi ok i see - it is hard to believe that hot water will circulate without a pump.
@rickwest2818
@rickwest2818 2 года назад
Shouldn't the line there and back be mostly insulated? Not the last 3 or 4 meters, or it won't flow. Sure, it slows it down, but it still works and saves energy.
@wadsworthplumbers
@wadsworthplumbers 2 года назад
Yes, that does improve re-circulation even more.
@arthurmink8481
@arthurmink8481 Год назад
Do i need to put a check valve in the return line to keep the water only pulling from the top of the water heater?
@oldarkie3880
@oldarkie3880 Год назад
yes, I also think a shut off valve even an automatic one is needed so that the water heater is not heating recirculating water 24 hours every day.
@spelunkerd
@spelunkerd 11 месяцев назад
A check valve is not needed since the energy to produce one way flow comes from the thermal gradient. The gravity system would be most efficient when the end user is above the tank. However energy costs are likely very significant, I will guess to a level of a few hundred dollars a year. Thin copper pipes radiate heat away very quickly compared to an insulated tank. The best way to do this would be to insulate all the outgoing lines from the tank to source, which would also increase the gradient and flow along the line.
@Dishpjl
@Dishpjl Год назад
where are you located?
@honolulu1476
@honolulu1476 2 года назад
Can you show how you connected it under the sink
@wadsworthplumbers
@wadsworthplumbers 2 года назад
We connected it just under the floor by connecting the recirc line to the 1/2" hot line.
@honolulu1476
@honolulu1476 2 года назад
@@wadsworthplumbers Thanks
@jfdesignsinc.innovationsid1583
@jfdesignsinc.innovationsid1583 4 года назад
Should insulate the lines
@wadsworthplumbers
@wadsworthplumbers 4 года назад
It will help create a temp differential which will assist in the gravity operation. But, it's not absolutely neccessary.
@jfdesignsinc.innovationsid1583
@jfdesignsinc.innovationsid1583 4 года назад
Mackin & Sons Plumbing , thanx for reply and What u said does make sense, Let’s say on new construction, You run a third line to the farthest fixture.... both hot and third line are insulated well...hot and third line are connected Together at the furthest possible point ...the third line is connected to hot water tank low at the drain valve,,,,(put a T fitting where drain valve is located on tank) ... would the temp differential in the tank itself push hot water sufficiently to accomplish what we want here? Basically we brought the tank to the fixture essentially... but now there’s 2 hot water supply lines for the hot side of all fixtures and one cold ? What do u think on that.. I think putting a check valve on the third line would hinder the differential flow... When heater is heating ... the top and the bottom are vastly different in temp.. cappallary action or reverse osmosis (lol) What’s your thoughts I’d like to hear from you... thx bud
@thedavesofourlives1
@thedavesofourlives1 3 года назад
would only help after the lines were primed with hot water. you wouldn't want to insulate the new return line as it needs to lose heat to work driving the thermosiphon.
@rickwest2818
@rickwest2818 2 года назад
@@jfdesignsinc.innovationsid1583 insulate the entire loop except for the last 4 meters into the boiler drain.
@joechristifano3990
@joechristifano3990 4 года назад
Does this require a check valve?
@wadsworthplumbers
@wadsworthplumbers 4 года назад
Not for any safety reason. We typically dont install them and haven't had any trouble.
@joechristifano3990
@joechristifano3990 4 года назад
Mackin & Sons Plumbing thanks for the reply! So with no check valve, what prevents cold water from the bottom of the tank coming up the return line when you open the faucet?
@gtb81.
@gtb81. 4 года назад
@@joechristifano3990 a bit late, but, thermodynamics, cold water is heavier than hot, so hot water will always want to be at the top
@paulnic7190
@paulnic7190 3 года назад
You cannot use a check valve in this configuration. It will prevent gravity circulation. Best to use a ball valve or globe valve on the return to the tank and open it just a little. That way you will always have more hot water than the cooler water from the bottom of the tank going to the fixture. It will be negligible to the final temperature at the fixture. I am a 40 year red seal plumber in Canada One more thing. Don’t cheap out and use galvanized fittings to connect to the tank. They will internally corrode. Use brass fittings
@joechristifano3990
@joechristifano3990 3 года назад
@@paulnic7190 thanks for the input! I’m now leaning toward just installing a mini tank water heater under the sink. Bosch makes one for about $150. Seems easier than the return line.
@greghanson8959
@greghanson8959 3 года назад
Can you run two return lines in a system? I.e., one from furthest first floor bath and another from second floor bath on opposite side of the house.
@wadsworthplumbers
@wadsworthplumbers 3 года назад
You could but the shortest or most direct loop will probably work best. I'd be worried the longer loop wouldn't work very well.
@greghanson8959
@greghanson8959 3 года назад
@@wadsworthplumbers Thanks for the reply. So putting the return line at the first floor bath would not "short circuit" hot water getting up to the second floor?
@wadsworthplumbers
@wadsworthplumbers 3 года назад
@@greghanson8959 No it won't affect the other fixtures.
@greghanson8959
@greghanson8959 3 года назад
@@wadsworthplumbers Thank you very much for the guidance. Now, if only your service area extended to Texas... :-D
@johnaustin1825
@johnaustin1825 3 года назад
You passed too quickly over the circulation method! Slow down! Explain in detail how to do it!
@wadsworthplumbers
@wadsworthplumbers 3 года назад
Noted
@drsony8
@drsony8 3 года назад
You didn’t show what you did 😏😏😏👎
@jcaleca60
@jcaleca60 3 года назад
You'd be better off with a pump Recirculating the hot water
@wadsworthplumbers
@wadsworthplumbers 3 года назад
Yeah, sometimes a pump makes more sense but a gravity recirc works in most cases.
Далее
Hot Water Recirculating Loop
6:58
Просмотров 121 тыс.
4 Plumbing Tricks I Haven't Seen Before!!!
9:19
Просмотров 1,8 млн
Самое неинтересное видео
00:32
Просмотров 844 тыс.
Starman🫡
00:18
Просмотров 9 млн
Новый хит Люси Чеботиной 😍
00:33
Hot Water Recirculation System
6:27
Просмотров 58 тыс.
Plumbing Hot Water Recirculater Pump
10:06
Просмотров 41 тыс.
Instant Hot Water - Smart Hot Water Pump
11:13
Просмотров 17 тыс.
Instant Hot Water Line Recirculation Part 1
9:42
Просмотров 121 тыс.
Best way to pipe Hot Water Recirc
5:37
Просмотров 26 тыс.
HOW TO: Get Hot Water in Seconds
3:04
Просмотров 470 тыс.
Самое неинтересное видео
00:32
Просмотров 844 тыс.