Using Lubricant to pull cables through conduit 

gunsparky
Подписаться 1,5 тыс.
Просмотров 17 тыс.
50% 1

We decided to try a few cable pulling lubricants. Some conventional and some not.

Опубликовано:

 

10 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 34   
@jonlen100
@jonlen100 Год назад
Years ago we had stuck cables in a conduit, and we poured the washing-up liquid in for a time they came out easy. UK spark
@wesleybeason7198
@wesleybeason7198 5 месяцев назад
Thanks for taking the time to make a video on this topic!!!!!
@johnoswald6192
@johnoswald6192 11 месяцев назад
Fricking awesome video 😄 Glad I found it before using PVA glue.
@danielwilliam9018
@danielwilliam9018 3 года назад
I enjoyed your video and appreciate your hard work. Never would have thought of using powder. In the elevator trade, we don't run wires all day every day but most guys would rather struggle than use wire lube. Not sure why. Works for me.
@gunsparky
@gunsparky 3 года назад
I had occasion once where I was pulling 4 * 16mm SDI through 60 run on a wall. Figured it was a straight run and probably wouldn't need lube. I got about 50 metres and didn't like the idea of pulling them out. I used compressed air to blow powder through. Problem solved.
@illestofdemall13
@illestofdemall13 3 года назад
In the US we need a pull box or pull point for every 360 degrees. Basically, you can't legally do more than 4 ninety degree bends in a row without a wire pulling access point. Then if you have another 5 or more nineties, you's have to put another pull point. We use junction boxes, LBs, etc. As far as lube, I use Ideal brand wire lubricant. I put some on the wire, and keep applying more as more wire is pushed in. I have used it for long runs in excess of 100 feet.
@gunsparky
@gunsparky 3 года назад
I can't think of a occasion when you would need 360° this is more to show what can be done. Cheers
@illestofdemall13
@illestofdemall13 3 года назад
@@gunsparky It happens a lot here when running EMT conduit (electrical metal tubing) on walls and ceiling in warehouses and things like that for long runs. Often there are obstructions, so every turn and offset adds to the degree count. It can also happen with PVC conduit when coming out of a main panel outside in the back or side yard. Sometimes we need to make a 90 out of the panel, a 90 into the dirt, two 90s around the corners of a house to get to another side. In that case we usually stub up and put a box somewhere in between. Cheers.
@OGCJ10
@OGCJ10 9 месяцев назад
@@illestofdemall13is it illegal ? Or is it against code?
@illestofdemall13
@illestofdemall13 9 месяцев назад
@@OGCJ10 it's against code but it can become a legal matter
@johndavies2949
@johndavies2949 3 месяца назад
If using PVC underground try cheap rv anti freeze. Environmentally safe, slippery than snot.
@theecumenicalchurchofoccit2439
@theecumenicalchurchofoccit2439 2 года назад
Cable lube enabled us to pull a cable more than 40 metres through some ridiculous underground twists and turns in a buried conduit. Highly recommended and it dried off within a couple of hours leaving no residue on the cable. The installation engineer warned us that some washing up liquids can eat into the cable covering....
@gunsparky
@gunsparky Год назад
Yeah that is true. This is just an experiment. I should do another one. Cheers
@OGCJ10
@OGCJ10 9 месяцев назад
Which lube would you recommend that won’t eat into the cable covering ?
@OriaXu
@OriaXu Год назад
Thanks, very interesting test video!
@vince6829
@vince6829 Год назад
Thank you for sharing.
@USMC-Sniper-0137
@USMC-Sniper-0137 2 месяца назад
How about dielectric grease??
@royormonde3682
@royormonde3682 3 года назад
You keep applying it to the wire for long runs as you feed it in just like all lubes.
@wearsjorge55
@wearsjorge55 7 месяцев назад
Kev! I just saw you in newtown, didnt get the chance to say hi but hope youre doing well mate
@ianshearer2437
@ianshearer2437 3 года назад
A rather interesting video...not being a sparky I learnt some excellent information
@gunsparky
@gunsparky 3 года назад
Really useful information I'm sure
@blackdatto
@blackdatto 3 года назад
I am loving your videos! Thanks
@gunsparky
@gunsparky 3 года назад
I'm a bit broken at the moment but I will be back into it soon
@blackdatto
@blackdatto 3 года назад
@@gunsparky hope you haven’t hurt yourself? That would be ironic after taking the piss out of safety crap
@gunsparky
@gunsparky 3 года назад
@@blackdatto it is ironic. Snapped a couple of ligaments practicing wheelies on a trail bike two months ago.
@blackdatto
@blackdatto 3 года назад
@@gunsparky Broken, your not kidding huh. Well if you make it over to the west coast at some stage I would enjoy showing you some hospitality. Only if you make us some more videos that is ;-)
@wearsjorge55
@wearsjorge55 3 года назад
You got this video idea while restocking the bedside table aye?
@gunsparky
@gunsparky 3 года назад
All of the products used are in the bedside table
@randymarsh007
@randymarsh007 3 года назад
Hey Kev Ex student here how are you mate long time no see ? I Enjoy the vids Kev only thing missing is your hemp shirt
@gunsparky
@gunsparky 3 года назад
I'm wearing a hemp shirt in this video.🤣😂🤣😂🤣
@goodvibes0101
@goodvibes0101 Год назад
You wont get a pay out for meso from talcum powder as you used it not for its intended purpose 😂
@gunsparky
@gunsparky 3 месяца назад
I live dangerously
@ziggzaggzip8241
@ziggzaggzip8241 Год назад
(((😂))))
@KarasCyborg
@KarasCyborg 2 месяца назад
Dish liquid! Didn't that J&J Talcum Powder Give People Genital Cancer. Hate to see what it will do to your lips.
Далее
How to Pre lubricate a conduit
8:03
Просмотров 111 тыс.
Что думаете?
00:54
Просмотров 514 тыс.
Preparing to pull wire
5:00
Просмотров 327 тыс.
Using A Conduit Snake For Electrical Wiring
9:24
Просмотров 10 тыс.
How to pull wire in conduit with a vacuum
6:52
Просмотров 20 тыс.
Wire Pulling Half Hitching Prep
6:07
Просмотров 115 тыс.
5 Mistakes DIYers make using metal electrical boxes
7:20
Blowing line through conduit with a leaf blower.
3:30