Thank YOU!! Just did this for the first time and I’m out in the field, success!!! Genie sent the board with the wrong programming and held the board for 2 weeks to program it 😂 . Video is greatly appreciated
Hi love you vid, it has helped me understand lots about the programming side, Thank you.. I am a new tech to this and was trying to adjust some values.. I now need to reset the board on this S65 and it keeps telling me ( An error has occurred in the script on this page).. If anyone can steer me in a direction that may help would be great.. If their is a discussion group I can join please let me know I have learnt some things in the short time working on there and I would like to assist other and hear the problems and solutions they may be having..
Great video. I have a Genie Z-60/34, giving me some trouble. When I touch the foot peddle the 2 boom flow control is energized, without doing any other function. I have gone through the normal checks re-calibrating the joy sticks and setting ALC 500 to all the defaults. On the ALC 500 board the light for the flow control shows on when the foot peddle is depressed, however on the WEB GPI it shows that the flow control is not on. So my question is there a hardware problem (short, relay stuck, etc. in the ALC 500 board) or is it a software problem( an IC misinterpreting information). and reinstalling the firmware would solve the problem.. Also all of the controls on the ground unit work perfectly fine.
To BUY Web Gpi you need to buy it from genie or maybe ebay. If you are needing the Application software You go to www.genielift.com/support/firmware, go to software matrix under model to down load all.
look up the wiring schematic on genie and power it up with power and ground then contact up with web gpi to make sure it is powered up right, then program
HELLO LIFT GUY ANOTHER QUESTION IAM OUT HERE IN JAMAICA S125 GENIE CANT EXTEN PAST 75 TO 80 FEET IT GIVE ME A SAFETY SWITCH CODE LSB8AS I REPLCE IT BUT STILL GIVING SAME CODE WILL THE WEB GPI LEAD ME TO THE PROBLEM
Web GPI will give you the state of the limt switches and when you extend it will show you the change in state. But there is two switches for the extend I believe one is the switch the other is a back up and the code comes up as the back up when it is the main. I would test the other switch inline with the one you replaced you probably find a problem with it.
if you are talking about Web Gpi you need to buy it from genie or maybe ebay. If you are talking about the application software You go to www.genielift.com/support/firmware, go to software matrix under model to down load all.
if you are talking about Web Gpi you need to buy it from genie or maybe ebay. If you are talking about the application software You go to www.genielift.com/support/firmware, go to software matrix under model to down load all.
@@liftguy9198 A query I get a fault code in man lift 125s LSB4ES when I extend the 2 drawers and the 3rd drawer does not appear, it comes out a little and it blocks me 'and that LSB4ES code appears
@@jaimevasquezpacco5234 first you can get the service manual off genielift.com. It sounds like you either do not have the boom raised up to the level to let it extend or you have a bad limit switch and the boom thinks its not high enough