Vaillant Turbomax plus Hot water problems.MOV 

unicuk
Подписаться 5 тыс.
Просмотров 138 тыс.
50% 1

The customer has got his boiler moved.. Since then the boiler is working fine for heating but hot water comes luke worm. Also.. sometimes when the hot water tap is on.. boiler is not coming on at all. Sometimes it comes on but continues on for considerable amount of time even when the hot water tap is closed. ( Heating demand was off) It seems to be more than one problem hear. Okey did they do the hot & cold water pipe work properly? Is it mixed or crossed? ....Next question is.. hey did they block the plate heat exchanger?.. or is it a problem with the PCB, Flow senser? or Hotwater NTC..? Well why did it go wrong when the boiler is just moved..I dont beleve in co insidents..What was faulty? I will give you a clue.. the boiler was repaired the next day because I did not have the part..(which was invented by Mr Hole who died without patenting his precious invention.... so .. poorly)

Опубликовано:

 

4 фев 2012

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 27   
@msgcheckout
@msgcheckout 9 лет назад
one of my friends had a hot water problem on a vaillant Ecotech plus 831, his hot water was barely luke warm and it turned out to be a mesh filter in the brass connecting block at the left side of the boiler , this connector block connects the pipe from the main hot water flow from the main heat exchanger and enters the brass block at the left side, and goes through a mesh filter, if this filter is clogged up the flow won't go through easily and cause the main heat exchanger to overheat whilst the hot water will be luke warm, get a tooth brush and insert from the left and throughly clean this in line filter mesh (also bolted to this brass connecting block is a pressure sensor, you can drain the top part of the boiler and remove the sensor to see if the filter is clogged up badly, if you don't see the white plastic mesh and see only brown or dark mess inside then it is certainly blocked up badly, also worth cleaning the plate domestic hot water heat ecxchanger with spirits of salt, pour it in and leave it for 5 minutes and no longer and flush it out thoroughly, this will losen all stuck up debri and other deposits, bring back heat transfer efficiency. You may get an F75 fault with this filter blocked, and as well as F22 overheat fault or dry run fault, but don't forget I am talking about an 831, who knows your vaillant may have a mesh filter too that is clogged up. To get to the filter, you have to drain the top part of the boiler, then remove the large pipe from the left going into this connecting block, this is a push fit connection retained by a clip, so pull the locking pin out and remove the big pipe out, and pull it away and clean the filter from the left, if filter is not stiff jammed inside, the filter sleeve mesh can be pulled out and cleaned outside and better this way. (anyone who can shag a bird can do this job, but please use precaution gas is lethal like HIV)
@willwyatt9801
@willwyatt9801 9 лет назад
What is the point in this video
@pawelhowson2120
@pawelhowson2120 11 лет назад
Hi,my boiler doing the same since last Wednesday. Heating seams work fine but hot water heats after couple of minutes and is not very hot. Whats going on??
@armyf9ify
@armyf9ify 11 лет назад
Took me a while to understand, but i think he's referring to the Aqua Sensor. Mr Hole = Hall Sensor.
@sparkinspain
@sparkinspain 6 лет назад
I actually thought they were looking for a leak under the sink !
@brunogarcia4916
@brunogarcia4916 9 лет назад
la caldera Vaillant se enciende bien y al momento se apaga no se que le pasa las luces se queda verde la de abajo y naranja la de la calefacion .
@armyf9ify
@armyf9ify 11 лет назад
Aqua sensor detects water flow. If it doesn't detect tap switching on/off (e.g no flow) it won't fire the boiler or may keep it on all the time until overtemp.
@stevennailedit
@stevennailedit 4 года назад
Thank you for explaining the video.
@marekmarek1334
@marekmarek1334 8 лет назад
switch off warm start and is work fine
@kerevizz
@kerevizz 12 лет назад
how did you solve this problem mate?thanks
@taz1058
@taz1058 Год назад
They didn't solve the problem that's why they uploaded it here to get info on how to solve. Cowboy builders pretending they can fix boilers
@taz1058
@taz1058 8 месяцев назад
How much u paying me to solve issue I'm a gas engineer and not a cowboy builder pretending to repair boilers they should be reported to Gas Safe.
@chinclow65
@chinclow65 9 лет назад
You must be very proud with your shallow, hollow and empty of logic video. So what did you do to resolve the issue????
@traian23us
@traian23us 9 лет назад
Flow sensor
@user-sp4ni8gg3v
@user-sp4ni8gg3v 11 лет назад
cast away the plug from the sensor nts on the secondary heat exchanger and all it to turn out! with love from Russia! ) )
@Taqqiyastar
@Taqqiyastar 11 лет назад
Diverter valve sticking and its needs replacing
@ZyleenxClubAsiaRadio
@ZyleenxClubAsiaRadio 11 лет назад
One of the worst video's I think Ive ever seen on you tube, no explanation and no solution...what was the point?
@izahmad46
@izahmad46 6 лет назад
Ridiculous
@dwjudd
@dwjudd 3 года назад
I agree, what a dumb video
@Itisinthehand
@Itisinthehand 11 лет назад
Stick to tarmacing drives then lads.
@apnamac
@apnamac 11 лет назад
No solution, Wot a knob
@taz1058
@taz1058 8 месяцев назад
All cowboys off of the banana boat are like that
@marekmarek1334
@marekmarek1334 8 лет назад
is warmstart
Далее
Vaillant Hot Water Issue
5:09
Просмотров 202 тыс.
Vaillant Ecotec Hydro Assembly Explained. Dr pipe
10:34
Vaillant Ecotec Boiler, Common Faults
17:57
Просмотров 762 тыс.
Vaillant Aqua Sensor How to test and fix the easy way
10:51
Vaillant boiler controls-no heating  hot water
4:11
Просмотров 296 тыс.