Тёмный

Viessmann Vitodens 050 Installation - ACS Gas Training - Assessment 

Allen Hart
Подписаться 125 тыс.
Просмотров 18 тыс.
50% 1

Combi Boiler Installed by Apprentice Plumbers. The Trainee Plumber from Viva Training Academy installing a new gas Combi Boiler. Gas engineer training.
Testing a gas meter. What do you need check when working on a gas meter. Earth bonding at gas meter. Installing a new boiler flushing the heating system and testing the central heating water afterwards. Taking out an old Baxi Combi Boiler and installing a new Viessmann Vitodens 050 Combi Boiler.

Хобби

Опубликовано:

 

16 сен 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 77   
@anthonyclinton1355
@anthonyclinton1355 3 года назад
Just wanna say Alan I've been watching some of your videos the last month or so and they are absolutely brilliant, jam packed with brilliant advice and information for gas safe engineers so keep up the great work Alan top man 👍👍
@rajid4968
@rajid4968 3 года назад
Really good job lads. Good to see the work completed looks professionally done ✔.
@markcliff9923
@markcliff9923 3 года назад
Cracking vid again Allen, how system cleansing as advanced, remember the old guy I started with in the late 70s always put an egg cup full of fairy liquid in the F&E cistern when we put a new heating system in ha ha.
@AllenHart999
@AllenHart999 3 года назад
Never done that myself but i might try it lol.
@tomadams94
@tomadams94 3 года назад
Eddie I think the assessor is called was my assessor at college too about 6 years ago. Nice man
@veronicahart450
@veronicahart450 3 года назад
👍 love your videos
@AllenHart999
@AllenHart999 3 года назад
Thanks Mum❤
@lucyyyy-v3m
@lucyyyy-v3m 3 года назад
👍🏻 good job
@davidb2464
@davidb2464 3 года назад
Hi Allen, Normally your video's are great, I'm putting in a couple of LPG converted Veissmans in a few weeks, and wondered if there were any little tricks/differences that I might find handy, but this video didn't show any of the install at all. It was handy to see the rig in place, nice and easy, some of the old combi's have a rig that needs a little persuasion like dismantling pipework from rig underneath etc etc. Keep up the good work.
@AllenHart999
@AllenHart999 3 года назад
Where abouts are you? I could come along and show you in person😂
@davidb2464
@davidb2464 3 года назад
@@AllenHart999 That would be excellent, I'm in N, Ireland if you fancy the trip. I'm just watching your other video with the really bad install (pipes, condensate, flue all terrible), it looks like I should have come here first, but thanks for the offer though.
@ashokrawal3820
@ashokrawal3820 3 года назад
Good job
@AllenHart999
@AllenHart999 3 года назад
Thank you.
@ArksE8
@ArksE8 3 года назад
One bit of info, always volt stick the meter and outlet before touching it.
@eazyrat
@eazyrat 3 года назад
Is the boiler isolated when doing the flush? Do you only run the water through the boiler for the hot flush? thanks
@rayc1503
@rayc1503 3 года назад
Turbidity tubes are good indication if you've flushed well 👍. I use the fernox test kit. The adey test kit seems a bit overpriced for what it is 🤔
@SalimKhan-gk1fh
@SalimKhan-gk1fh 3 года назад
Another excellent video Allen and a good boiler choice too! Is there any reason why the pressure gauge was over 3 bar when kulbir was putting it into service mode? Or is it because it was filled too a high-pressure to be flushed? As always enjoyed watching it !🙂
@AllenHart999
@AllenHart999 3 года назад
Salim Khan Well spotted that 😂😂😂 it had been left open while flushing
@SalimKhan-gk1fh
@SalimKhan-gk1fh 3 года назад
Allen Hart Yes I thought that might be the case ! I’ve checked with viessmann and they recommend the cold pressure ,static , is one bar only
@SalimKhan-gk1fh
@SalimKhan-gk1fh 3 года назад
Allen Hart hi Allen ,Just a matter of interest who decides on the Viessmann boiler being chosen ? was it you or the customer?
@SulaymanHamid
@SulaymanHamid 3 года назад
Can u solvent weld 4” underground pipe? I taught u couldnt. Cheers
@AllenHart999
@AllenHart999 3 года назад
I have never done it before. We didn’t know it was going to be underground pipe. If there are any issues at all we will change it. Thanks.
@richardhodgson7443
@richardhodgson7443 3 года назад
Great video .. be me soon 🤞
@sundarali9648
@sundarali9648 3 года назад
Hi Alan i am looking to get in to plumbing what is the best root to be come gas safe register plumber .thank.s any advice would be really helpful .
@AllenHart999
@AllenHart999 3 года назад
What area do you live? Thanks
@sundarali9648
@sundarali9648 3 года назад
Allen Hart Chesterfield. Derbyshire
@sundarali9648
@sundarali9648 3 года назад
Thank you for your reply
@stuartcarr7717
@stuartcarr7717 3 года назад
Allen ive got baxinplatinum when i use hot water tap in kitchen the water is hot after i turn off water theboiler makes noise for anothe minute and half
@waheedjalali1618
@waheedjalali1618 3 года назад
Does the noise mean it overheats Allen ?
@stuartcarr7717
@stuartcarr7717 3 года назад
@@waheedjalali1618 could it be pump over run
@waheedjalali1618
@waheedjalali1618 3 года назад
@@stuartcarr7717 Yeh u could be right actually I have been working as an apprentice And my thought is eighter overheat or blocked heat exchanger
@factorclassic
@factorclassic Год назад
how would inhibitor change ph strip colour? this can't be right, ph strip is only for ph test, end of.
@40commando
@40commando 3 года назад
Do you recommend this boiler
@AllenHart999
@AllenHart999 3 года назад
They are a good boiler and this one has a 10 year parts and labour warranty. Thanks.
@whitebear5405
@whitebear5405 3 года назад
Doesn't that system flush drive all the dirty water through the plate?
@AllenHart999
@AllenHart999 3 года назад
How would it do that? Thanks
@keithbrueton
@keithbrueton 3 года назад
I like the sound of that strap on
@robdegoyim4023
@robdegoyim4023 3 года назад
keith brueton kinky
@AllenHart999
@AllenHart999 3 года назад
Ha Ha
@robswingler
@robswingler 3 года назад
Bonding can be within 600mm of where it enters the property and depending on the earthing system it can be as low as 6mm . If the gas pipe is plastic on the intake and it’s not extraneous or re enter the floor down the line it doesn’t require bonding .
@AllenHart999
@AllenHart999 3 года назад
Where does it say that in BS7671 as I am unable to see it? Thanks.
@robswingler
@robswingler 3 года назад
Allen Hart which part?
@robswingler
@robswingler 3 года назад
Allen Hart page 202 reg : 544.1.1 for minimum size being 6mm
@AllenHart999
@AllenHart999 3 года назад
robert swingler Doesn’t say that in our gas books.
@robswingler
@robswingler 3 года назад
Allen Hart page 58 reg 411.3.1.2 or on site guide page 49 section 4.5 ( bottom of page) for plastic intakes 👍
@chengambj
@chengambj 3 года назад
Please correct me if I'm wrong but I thought Viessmann do not recommend the use of inhibitors in their boilers. I'm guessing it's something to do with the rubber hoses.
@SalimKhan-gk1fh
@SalimKhan-gk1fh 3 года назад
Mark B Jones No mark viessmann do not recommend any inhibitors in the system water it’s something to do with the chemicals in inhibitor that cause particles in the stainless steel heat exchanger
@chengambj
@chengambj 3 года назад
@@SalimKhan-gk1fh Thank you, so Mr Hart you were wrong to use inhibitors in the system.
@chriswilliams76
@chriswilliams76 22 дня назад
That a speed fit cap end on gas ? inappropriate fitting
@izmirfpv6145
@izmirfpv6145 3 года назад
hi can you tell me about parameter menu pls??
@AllenHart999
@AllenHart999 3 года назад
Next one i install 👍
@izmirfpv6145
@izmirfpv6145 3 года назад
@@AllenHart999 Thanks wait for you vitodens 50 w
@keithbrueton
@keithbrueton 3 года назад
Oh no its erm again
@AllenHart999
@AllenHart999 3 года назад
Danny's back lol.. Thanks.
@k20aa
@k20aa 3 года назад
There he goes again with the cheap labour LOL only joking good work allen
@AllenHart999
@AllenHart999 3 года назад
My jobs take twice as long lol... Thanks.
@Falco45able
@Falco45able 3 года назад
That vent pipe looks horrendous , otherwise very informative fella!😉
@AllenHart999
@AllenHart999 3 года назад
Which pipe do you mean? Thanks.
@Falco45able
@Falco45able 3 года назад
The light brown 4 inch at the side of the toilet!😉
@dzmalekvali1110
@dzmalekvali1110 3 года назад
Plastic boiler...no lasting
@AllenHart999
@AllenHart999 3 года назад
They have a built in shock on these, I haven’t personally seen one fail yet. Have you seen any? Thanks
@SalimKhan-gk1fh
@SalimKhan-gk1fh 3 года назад
DZ Malekvali it’s a metal boiler actually .
@SalimKhan-gk1fh
@SalimKhan-gk1fh 3 года назад
Allen Hart No I haven’t seen one yet Allen in the 12 to 14 years I’ve been dealing with viessmann boilers
@dzmalekvali1110
@dzmalekvali1110 3 года назад
@@SalimKhan-gk1fh ,,,salim 50 %Plastic
@SalimKhan-gk1fh
@SalimKhan-gk1fh 3 года назад
DZ Malekvali I’ve been fitting these for over 14 years now and I have not had a plastic housing leak this is not a Worcester Bosch you know the plastic housing are made by grundfos,
Далее
Камень, ножницы, нейронка
00:33
Просмотров 1,3 млн
ПОДВОДНЫЙ ГЕЙМИНГ #shorts
00:22
Просмотров 709 тыс.
Я ВЕРНУЛСЯ 🔴 | WICSUR #shorts
00:57
Просмотров 792 тыс.
Vitodens 100
18:22
Просмотров 13 тыс.
ACS Gas Training - Installation Faults Q&A
26:53
Просмотров 25 тыс.
Viessmann vitodens 050 краткий обзор
9:54
Viessmann vitodens 050
13:15
Просмотров 18 тыс.
Don´t WASTE FOOD pt.2 🍕
0:19
Просмотров 54 млн