TB118 ELECTRICAL SAFE ISOLATION - Boilers - ACS Gas Training ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-5mIb8p3mYlQ.html TB118 Electrical Safe Isolation - When Things Go Wrong ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-m7ffKTYo7Jk.html New Gas Boiler Installation - Benchmark Code of Practice ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Lf87taSzaIA.html
Mi's need to be easier to find important information. As a new gas engineer or an old one like me with bad memory, I can't always remember how to put a boiler in high/low mode to run tests. And it's not always easy to find the optimum gas ratios in the mi either. Worcester are good in this case. Easy to put into service mode and easy to find correct readings also
Hi Allen I'm really happy you make these videos and go out your way to help others become successful. Just one correction because I'm preparing for the test soon and going through past papers. After the ECV it's the regulator that reduces the gas. They try to trick us by putting governor as one of the answers.
Absolutely brilliant video! I only got these because I’ve had my face in the viper gas books for the past couple of months. The other two things that I thought might be an issue is where the earth cable for the meter comes through the wall it has to be sleeved / sealed. The clips look like steel on the copper gas pipe, I might be wrong but doesn’t that cause corrosion?
Hi Allen, I passed my gas right out of college which has expired 2 years ago... used to have vast experience on gas works but been on site now for 2 years... do you have any advice as I want to renew my gas but feel I have forgotten a shed load
Great videos thanks,Regards the Baxi service manual is this only issued by Baxi if ive been on Baxi training course ? can only see installation manuals on baxi website .
Brilliant video .... Clipping distance Clips required on boiler pipework Too close to electric wire Think I spotted flux residue on meter pipework Sleeve / sealed Was that earth 6mm Pipe sizing looked correct AR flue seal Bench mark & cp12 incorrectly filled out Dont think the condense pipe should be open ....surely should be sealed ! DLM looks ok @ 4ohms Final Flue integrity test with case on Wonder what cooker was like lol. Have you got any videos on when you would ID a cooker Allen. Thanks for your time doing these videos. 👍👏👌
Gas boilers are not getting banned, but as from 2022 I believe all new build properties will not be allowed gas installed, they will need to be electric heating, however there are trials as we speak in the midlands area where hydrogen is being introduced into the gas supply to ascertain whoever we can switch to a mixture of gas and hydrogen for the remaining millions of boilers out on the patch. Hope this helps
@@AllenHart999 got the electrics too close to the pipe. that pipe teeing up through the ceiling should be clipped/supported too right? what would happen with those wires in the end? either the pipe or the wires need to be moved? would end up quite a job?