View of Things - WinCC Unified HMI visualization running on S7-1500 PLC Webserver | TIA Portal V17 

AutomationStation
Подписаться 4,5 тыс.
Просмотров 8 тыс.
50% 1

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 10   
@mohamadismailbasha6083
@mohamadismailbasha6083 2 года назад
Glad to have found this channel. But last video is 3 months old! Hopefully the channel is still active.
@AutomationStation
@AutomationStation 2 года назад
Not that much time recently but if something is of interest let us know in the comments ;)
@akshaypotdar1840
@akshaypotdar1840 3 года назад
Have recently come across this channel, it is very informative and useful. Could you possibly make a video on secure profinet communication between PLC and profinet devices with physical firewall in between. Also, if possible could you touch on the use of MQTT for profinet data transfer? TIA
@AutomationStation
@AutomationStation 3 года назад
Is there any reason for you looking into this? PROFINET being the field level protocol has to meet many requirements related to performance, real-time capabilities etc and you wouldn't really place a firewall between an IO Controller and an IO Device unless if maybe it was set to pass all the PROFINET frames as these are specific and different to normal IP communication. Use of MQTT for PN exchange is even less realistic again because PROFINET is a protocol of it's own and there's activity on lower network layers in addition to the application oriented layers. MQTT is just a protocol that sit's in the Application layer, usually using TCP. You can use MQTT to exchange data - that's ok, but not in a way PROFINET does. I would probably point you to the PROFINET foundation that has many good resources on PROFINET. Here's an example: us.profinet.com/profinet-network-geeks-want/
@rubenwinsjansen7558
@rubenwinsjansen7558 3 года назад
Can view of things fully replace a standard HMI solution, or is there any major drawbacks? Let's say i buy a random tablet with windows 10. Set up automatic start of chrome in kiosk mode on startup.
@AutomationStation
@AutomationStation 3 года назад
It's quite cut-down compared to full Unified, but if all you need is a basic visualisation then it might be fine for your requirements.
@Ana19978
@Ana19978 2 года назад
Can i use it for s71200?
@AutomationStation
@AutomationStation 2 года назад
Not today I don't think it can.
@hamedmoradi8737
@hamedmoradi8737 2 года назад
Total waste of time. Vot doesnt support more than 100 tags. S7 1500 is only used for big projects and yet this stupid idea doesnt allow more than 100 tags to be implemented in several pages. If i had only 100 tags i would have had bought a delta plc with lower price
@AutomationStation
@AutomationStation 2 года назад
It's not meant to replace a full blown HMI or SCADA really. If you need a simple visualisation that's the way to go. If you need a more complex one, just go for a HMI/SCADA/Runtime