Тёмный

Vitodens 100 Fault F4 

Viessmann Climate Solutions North America
Подписаться 4,8 тыс.
Просмотров 28 тыс.
50% 1

IMPORTANT - This video is intended exclusively for licensed mechanical contractors.
The equipment referenced in this video may differ from the equipment being installed or serviced on site. Please refer to the documentation supplied with the equipment before following any instructions contained in this video.
If there is no documentation available on site, please download the appropriate product manuals from our website at:
www.viessmann.ca/en/Residentia...
Viessmann does not assume any responsibility or liability whatsoever for any action taken as a result of viewing this video. Information obtained through this video cannot be relied upon as a substitute for receiving proper training or assistance from other trained personnel.

Наука

Опубликовано:

 

12 апр 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@George-id7cd
@George-id7cd Год назад
THANK YOU VERY MUCH
@webdvdforyoutube8689
@webdvdforyoutube8689 4 года назад
00:00 Start 01:09 *Fault 'F4'* 01:10 Display - Fault 'F4' 01:47 Fault Information 03:59 Natural Gas Combustion Simplified 05:37 Flame Rectification | Ignition Safety using Flame Conductivity 07:10 *Fault 'F4' | Troubleshooting* 07:10 01 | Checking Polarity 08:20 02 | Checking Ground 09:40 03 | Checking Ignition/Ionization Block 11:17 04 | Checking Resistance of Cable 12:10 05 | Measuring Flame Signal 13:25 06 | Checking Gas Pressure 15:00 • Gas Supply Issues High Lockup Pressure 17:18 • Copper Gas Line Issues 17:55 • Water in Gas Valve 18:34 07 | Checking Gas Valve 18:35 • Voltage 19:09 • Resistance 20:09 08 | Venting Issues 20:09 • Checking Vent Pressure 23:36 • Negative Pressure in Buildings 25:16 • Impact of Negative Pressure 25:54 • Rigid Single Wall Venting Layout 25:54 - Supported 26:41 - Not Supported 27:44 • Contaminated Combustion Air 31:14 09 | Clean Boiler 31:15 • If Unit Have Not Been Serviced 32:57 • Condensate Removal Connection I made these chapters with WebDVD. If you like chapters then watch the 'WebDVD' version of this video: webdvd.vidibook.com/webapp/index.php?11c7OZmAQAhV Hope you enjoy it - Thomas
@gelatskitishvili5807
@gelatskitishvili5807 3 года назад
just installed new vitodens 100 and there is f4 error, boiler not able to ingnition gas
@diqili1508
@diqili1508 5 месяцев назад
Hello, what is the correct range for the vent pressure?
@ViessmannClimateSolutionsNA
@ViessmannClimateSolutionsNA 5 месяцев назад
To serve you better and provide the most suitable answer to your question, we kindly request that you connect with our Technical Service Department. By doing this, our team can ask some initial questions to get a clearer picture of your needs and provide a tailored solution for you. We're here to provide comprehensive support and look forward to assisting you further!
@pubchat2913
@pubchat2913 3 года назад
Great video thank you Though I’m having a hard time finding your orange app, is it still available? I’m in Canada, thanks
@chrissadowski2669
@chrissadowski2669 3 года назад
Hi Pub chat , Where in Canada you are ? If you do not mind asking
@pubchat2913
@pubchat2913 3 года назад
@@chrissadowski2669 Toronto Ontario
@chrissadowski2669
@chrissadowski2669 3 года назад
Pub Chat , are you in plumbing, heating business by any chance?
@pubchat2913
@pubchat2913 3 года назад
@@chrissadowski2669 yup hvac, heating and A/C
@sebseb5808
@sebseb5808 Год назад
HELP! Our Viessmann 100 got full service after F4 appeared-cleaned burner, cleaned waste trap, new burner seal, new ignition rod, fine for a day or two and then F4 came back intermittently untill it would not fire with permanent F4 3 weeks later, Got new PCB installed and worked like new for a day and suddennly fucking F4 came back permanently. ANY IDEAS?
@louayalhousan8447
@louayalhousan8447 8 месяцев назад
Hi, same issue here, did you fix it in the end? what was the fault please? Thanks
@sebseb5808
@sebseb5808 8 месяцев назад
@@louayalhousan8447 in the end it turned out to be something wrong with the flue but I don't know the details. I got the Wiessmann specialist came and look and it took him less than 5 mins to figure it out and another 3 mins to fix it and he only charged me some silly money for a call out
@gianlucabassi8853
@gianlucabassi8853 2 года назад
The solution Is keeping the old good heating system