This video shows to rectify inlet valve not working, Drain motor not working, Main Motor not working, Easy method to repair the PCB, Simplified solution to this problem

Опубликовано:

 

11 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 100   
@shivajimulik1960
@shivajimulik1960 15 дней назад
Very nice explained..thanx.
@balasamygc3680
@balasamygc3680 6 месяцев назад
Bro really helpful and way of explaining is really understand able
@sharathbj7700
@sharathbj7700 2 года назад
Sir good information thank you very much for your information please make more videos which will help us your explanation is also good
@technoolab3514
@technoolab3514 2 года назад
Thank you, Yes will make some more videos
@mukeshpranami6092
@mukeshpranami6092 Год назад
Sir very important video my pcb sem problem 100k r Cheng and working OK sir Hindi language Im not English Thank you very much
@mubarakbenu3405
@mubarakbenu3405 2 года назад
thanks sir make more videos about washing machine ac pcb u r teaching method is very sweet and honesty
@technoolab3514
@technoolab3514 2 года назад
Thank you Mubarak benu, your comment is encouraging, will surely make some more videos
@user-zf2xy3bp7z
@user-zf2xy3bp7z 7 месяцев назад
mera machine ka inlet direct ho geya. power on karneke sath sath valve active ho jata hay. may ne inlet valve change kiya, valve ic change kiya resistor check kiya jo kharap tha who bhi change kiya.phir ye problem aaa raha hay. kya kar sakte hay can you please explain me?
@anfoods4462
@anfoods4462 8 месяцев назад
My inlet valve is ok but continuously it is getting 220volts from pcb what might be the issue?
@user-kp7gf2gl4d
@user-kp7gf2gl4d 5 месяцев назад
Drain ic replacement. Is ic same as inlet valve ic wiring
@satishbhanang3064
@satishbhanang3064 2 месяца назад
sir ic 2003 to inlet and drain which resistance value Sir
@rahulpatelgujratahmedabad3497
@rahulpatelgujratahmedabad3497 2 года назад
🅰️🅱️🕉️🕉️GOOD TEACHING FOR YOUR CHANNEL🚦THANK YOU SO MUCH VERY VERY GOOD 👌
@ArefinsZone
@ArefinsZone 7 месяцев назад
same problem facing. but my washing maching work perfectlybut only inlet valve not working. but when i put water manually then it wash everything perfectly. I changed the inlet valve ic but still not working. what should i do?
@technoolab3514
@technoolab3514 7 месяцев назад
1:36 check and replace switch shown in the video
@ArefinsZone
@ArefinsZone 7 месяцев назад
@@technoolab3514 but drain motor work perfectly but inlet valve not working. i also changed inlet valve switch but still not working. i tested the voltage of inlet valve that is showing 000
@bhaskardorairaj404
@bhaskardorairaj404 2 года назад
Very good info sir, my same wm programe and start switch is not working, pls help
@nitinmangle6927
@nitinmangle6927 Год назад
Sir one problem is in LG TOP LOAD washing machine inlet valve have continous supply when machine main supply on means water continue on so if i checked at valve continous supply shown so pls suggest solution is it possible triac is on when main supply on. Is it possiblw when triac shortckt it may continues on?
@technoolab3514
@technoolab3514 Год назад
Yes most possible
@nitinmangle6927
@nitinmangle6927 Год назад
Thanks sir Could i replace triac
@technoolab3514
@technoolab3514 Год назад
@@nitinmangle6927 check if the terminals are shorted, then go ahead and replace
@jamessechube426
@jamessechube426 Год назад
Sir..... my problem is that I replaced 2x dead hot and cold ACS TRANSISTOR with BT136 and now the water solenoid and drain is always on...
@tadessewoldeyes5299
@tadessewoldeyes5299 Год назад
Sir, I have similar problem. Everything looks perfect on tge pcb, but tge drain motor and pump are not working. What could be the source of the probkem?
@knr7231
@knr7231 Год назад
My board is same sir..... Everything ok but water not taking..... 4E error... Water valve changed... But water not taking... Plz reply what can i do
@bharatpatil3576
@bharatpatil3576 2 года назад
Sir mera yahi pcb hai but usme inlet valve direct on ho raha hai, inlet valve ka trasistor bhi ok hai dusara laga ke bhi dekha but same problem, please solution please
@technoolab3514
@technoolab3514 2 года назад
Full video pir se dekna ji, kia check karna video may Hai, nahi Hua to message karo
@paradiseshah
@paradiseshah Год назад
Panasonic front load washing machine NA123 vb3 shows 'END' message as soon as the wash selector is set and door is not locked with outlet motor starting. Pressure sensor is good. Pcb board no AXW24V-18738
@technoolab3514
@technoolab3514 2 года назад
correction, pin 4 is inlet valve input signal and pin 6 is drain actuator input signal to IC 4 (Darlington IC)
@rahulchowdhury3007
@rahulchowdhury3007 Год назад
I have same PCB board in machine. Everything is working but during washing and rinsing the timer gets stuck and blinks once every motor trigger. In short it keeps on washing and rinsing with a relay trigger sound and all lights blink once ever trigger.
@knr7231
@knr7231 Год назад
Hello sir... My board is same sir..... Problem is water valve not opening sir... Valve changed... But no use. Power continuesly coming to valve... Sir but how much voltage coming to valve i don't know sir... But valve not opening.what is the problem sir
@technoolab3514
@technoolab3514 Год назад
What is the voltage you are getting across the valve, valve voltage is 230v
@knr7231
@knr7231 Год назад
@@technoolab3514 i will check sir... If voltage below 200v, what can i do sir..
@amirthalingamthanakodi474
@amirthalingamthanakodi474 2 года назад
Samsung front load washing machine water over flows 4E came .pr. switch and hose checked ok .which point i should check in main pcb relay or control pcb
@technoolab3514
@technoolab3514 2 года назад
Could be due to scaling, please Ensure free flow of water in sensor pipe
@agravatdarshanbhai2349
@agravatdarshanbhai2349 9 месяцев назад
Acst 10357 me dusri konsi ic chalega
@amritaramsook7719
@amritaramsook7719 2 года назад
Hi I have the same PCB relay was bad I change it but nothing happing now one led blinking alone
@IrfanTechnician
@IrfanTechnician 2 года назад
Sir water level sensor ke liye kina volteg aani chahiye
@aravindsundaresh203
@aravindsundaresh203 2 года назад
Sir I have same board..my problem in 12 v short...when I check all components all r gud but don't get 12v standerd but I dummy the Darlington ic 12v pin then I get 12v...so what is the problem..is that ic had been defected
@technoolab3514
@technoolab3514 2 года назад
All components good, then Darlington IC could be the problem, there is one more Darlington IC of same number in the display board, you can use that and confirm
@aravindsundaresh203
@aravindsundaresh203 2 года назад
Sir I changed two ics now I get 5v and 12v but there is no leds and display not working but power button and buzzur are working remaining button not function what is the reason sir
@technoolab3514
@technoolab3514 2 года назад
@@aravindsundaresh203 is the seven segment display working?
@aravindsundaresh203
@aravindsundaresh203 2 года назад
No sir display also not working only power switch working when we press power buzzur will give sound we can on and off that switch remaining switch and display not working I changed display side ic also but no use
@banugopanrajendran4253
@banugopanrajendran4253 2 года назад
Brother , In this same model pcb , we face the water inlet solenoid is open immediately after switch on the machine , even during spinning throughout all operation . how to solve this please help.
@technoolab3514
@technoolab3514 2 года назад
Have you replaced with the same type (AC)
@williamtan7847
@williamtan7847 2 года назад
@@technoolab3514 what u mean same type ac? Where it is? What value? Thank you
@Benz-pcb-soluations
@Benz-pcb-soluations 2 года назад
Sir all resistor are showing ok, also changed transistor but facing same problem, what to do. Please guide me
@technoolab3514
@technoolab3514 2 года назад
There are five more interupt pins to this micro processor, this video i have explained one path, Please check display board, if Possible will make another video for remaining intrrups shortly
@uttambiradar6768
@uttambiradar6768 2 года назад
@@technoolab3514 please tell other reason for same problem
@sureshkrishnaswamy4229
@sureshkrishnaswamy4229 2 года назад
Sir, How to identify PCB is not working. There is lot ls of possibilities of few technicians misguiding users regarding failure of PCB. Since it is an costly affair please help me to understand.
@technoolab3514
@technoolab3514 2 года назад
PCB out put to be checked, ie out put of PCB at Feed valve terminal, Drain motor terminal using multi meter
@XPLOD_OP
@XPLOD_OP 2 года назад
ii pcb ka price kya hai
@johannesvanjaarsveld3800
@johannesvanjaarsveld3800 2 года назад
My defy automatic toploader washing machine drain motor runs continuously when the machine is starting to fill up
@technoolab3514
@technoolab3514 2 года назад
Please check AC switch for drain motor, I have mentioned in the video
@rakeshtevatiya3347
@rakeshtevatiya3347 2 года назад
LNK 306DG . ये marq वाशिन मशीन की pcb की आईसी है मिल सकती है क्या सर , swicher iC है ये ,
@technoolab3514
@technoolab3514 2 года назад
Please check the below link
@technoolab3514
@technoolab3514 2 года назад
www.mouser.in/ProductDetail/Power-Integrations/LNK306DG-TL?qs=fDnuuCn74qFupN%2F1O4D7Dw%3D%3D
@rubendeasis2300
@rubendeasis2300 2 года назад
Sir favor what is the alternate of triac 204s8e for drain motor ..thanking u in advance..
@technoolab3514
@technoolab3514 2 года назад
These are the equalents MAC 97AB M922 BT136
@rubendeasis2300
@rubendeasis2300 2 года назад
@@technoolab3514 thank u so much sir..
@CFERES16
@CFERES16 2 года назад
Hi good video, please tell me what transistor is labeled IC7 on pcb (for drain motor) .
@technoolab3514
@technoolab3514 2 года назад
Thank you, IC7 Is a power module
@CFERES16
@CFERES16 2 года назад
@@technoolab3514 Please tell me the exact module ID or specifications for a replacement . I need to replace my burnt-out module.
@technoolab3514
@technoolab3514 2 года назад
@@CFERES16Part number is BP5055-12, 220VAC Input/−12VDC (250mA ) Output Non-Isolated AC/DC Converter, Please check below link for further details
@technoolab3514
@technoolab3514 2 года назад
datasheetspdf.com/pdf/924354/Rohm/BP5055-12/1
@joselicop872
@joselicop872 Год назад
Sir appreciate more if video is zoomed to the PCB
@technoolab3514
@technoolab3514 Год назад
Agreed
@nandkishorgiri1174
@nandkishorgiri1174 2 года назад
Hindi
@banugopanrajendran4253
@banugopanrajendran4253 2 года назад
Brother , please tell some alternate triac for ACS120-7S (used for drain motor)
@technoolab3514
@technoolab3514 2 года назад
Use BT136
@banugopanrajendran4253
@banugopanrajendran4253 2 года назад
Thank you brother
@uttambiradar6768
@uttambiradar6768 2 года назад
Please tell other reason micro no output
@vijayakarekar
@vijayakarekar 2 года назад
In this path what's the roll of transistor .
@technoolab3514
@technoolab3514 2 года назад
As logical input to the micro processor (External interrupt input ) connecting INTP6 pin 1 of micro processor
@vijayakarekar
@vijayakarekar 2 года назад
@@technoolab3514 as you directed in your video ...after cheaking 100k resistors and 1k resistor .... replacement of transistor is successful story of my job.....thanks bro.....
@rishirathour3973
@rishirathour3973 2 года назад
my pcb this problem note working motor & drain pcb not command motors
@technoolab3514
@technoolab3514 2 года назад
Kia problem, hindi may batha sak the ho?
@giri.b3938
@giri.b3938 2 года назад
Sir this pcb inlet value countinuesly on
@technoolab3514
@technoolab3514 2 года назад
i have mentioned AC switch for inlet valve in the video, could be short, Please check and replace.
@tysonmodestus8520
@tysonmodestus8520 2 года назад
My washing machine continuously draining please help
@technoolab3514
@technoolab3514 2 года назад
Drain motor AC Switch is short, I have mentioned about AC switch in the video
@tysonmodestus8520
@tysonmodestus8520 2 года назад
@@technoolab3514 where can I located the AC or could you please send me the link
@technoolab3514
@technoolab3514 2 года назад
@@tysonmodestus8520 watch the video carefully, I have shown where the AC switch for drain motor is.
@tysonmodestus8520
@tysonmodestus8520 2 года назад
@@technoolab3514 thank you
@raghavahosur6621
@raghavahosur6621 2 года назад
Sir, Can you please share your address, I have a Whirlpool washing machine PCB issue. Thanks in advance.
@technoolab3514
@technoolab3514 2 года назад
Provide your e-mail ID.
@lokeshlokesh9620
@lokeshlokesh9620 23 дня назад
Motor auto run
@syedzuhaib4248
@syedzuhaib4248 2 года назад
sir your video is very useful.. thank you. plz provide your contact detail in bangalore
@technoolab3514
@technoolab3514 2 года назад
Thank you, pls provide your email id
@nandkishorgiri1174
@nandkishorgiri1174 2 года назад
Langwej hindi hona sar ji
@technoolab3514
@technoolab3514 2 года назад
Zaroor karenge
@XPLOD_OP
@XPLOD_OP 2 года назад
pcb ka price kya hai Samsung
@technoolab3514
@technoolab3514 2 года назад
Please check the link below
@technoolab3514
@technoolab3514 2 года назад
www.indiamart.com/proddetail/samsung-washing-machine-pcb-18475722648.html
@vamshikrishnavamshikrishna7233
Adrees
@Benz-pcb-soluations
@Benz-pcb-soluations 2 года назад
Can I call you sir
@sirfan6146
@sirfan6146 2 года назад
Sir telugu spech
@sirfan6146
@sirfan6146 2 года назад
Plz
@technoolab3514
@technoolab3514 2 года назад
Irfan ji I'm not fluent in telugu.
@sirfan6146
@sirfan6146 2 года назад
Hindi sir
@technoolab3514
@technoolab3514 2 года назад
@@sirfan6146 ya sure.
Далее
SAMSUNG top load washing machine pcb repair
10:05
Просмотров 16 тыс.
Они захватят этот мир🗿
00:48
Просмотров 844 тыс.
Как вам наши образы?🥰🥰🤍🤍
00:10
Sharp Inverter Washing Machine NO POWER!! How to fix?
19:18
Dead Washing Machine Pcb Repair Full Video
16:42
Просмотров 30 тыс.
Lg Washing Machine Pcb Repair Dead set all Voltage ok
14:29