What Goes Wrong ? - Shed Power Install 

AdamDunlopElectrical
Подписаться 48 тыс.
Просмотров 14 тыс.
50% 1

In This weeks video we are installing shed power into these 2 sheds however one shed is not the most well built and is a bit rickety as you shall see from the video and there's a potential its being taken down and re built so I would have to to re install this work , Aside that this job was really nice and overall finish of this job is very good and I'm happy with the isolation switches that gives it that extra touch.
#tools #electrician #milwaukee #trending
Verso - www.versoelect...
UNILITE - unilite.co.uk
SOCIALS - linktr.ee/adam...
Thanks for watching :)

Опубликовано:

 

15 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 91   
@danielrowe2119
@danielrowe2119 10 месяцев назад
Personally I would of clipped the cables at high level on the shed walls and then dropped down to the sockets. I get that it’s only a shed, but having them loose like that makes them prone to damage. It’s all a learning curve, keep up the good work.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Cheers
@anthonybragg
@anthonybragg 10 месяцев назад
@@AdamDunlopElectrical Yes, I would agree with the comment about clipping at the top and coming down they are out of the way of getting damaged by items being stored also those panels have thin wood braces I would be wary of weakening the structure. I hope this job was not too far from you as what you have to consider is that is three visits and each visit costs you money to get there.
@brianoneill350
@brianoneill350 10 месяцев назад
Agree, would have dropped down in conduit. Would have put in noggins for sockets also and stainless steel cable ties with conduit. You are good to show your work as that’s how we all learn. I would not run those t and E horizontally like that again. Someone will put something heavy on it and will drag it down. Cost is important but customers also need to trust you to recommend a good job. I would be very slow to do a shed without conduit or poor man’s trunking, high level with drop downs. Thanks for video. Keep it up
@ForTheBirbs
@ForTheBirbs 10 месяцев назад
Good stuff Ad!. One suggestion is to consider fitting wireless linked optical smoke alarms in the sheds if they're charging ebikes etc. Cheers
@shortcircuit7149
@shortcircuit7149 10 месяцев назад
Could have done a catenary to shed 2 to avoid those concrete panels. Also as above not a lover of the low clipping.
@paulpaddisonable
@paulpaddisonable 9 месяцев назад
Top job Adam. I totally agree with you on the shed build quality. New sheds are expensive and very poor quality. I built a new wooden shed recently and regret it. I should of spent extra and brought a plastic one.
@LeedsElectrician
@LeedsElectrician 10 месяцев назад
Looks good, i think i would have gone for a 6mm from the house to a 5way board then 2.5 to the second shed with some galv conduit for the cables so they dont get caught or damaged, You know that cable will be used to hang stuff from
@johnmcfadden7418
@johnmcfadden7418 9 месяцев назад
Hi Adam nice job mate no criticisms here but was the sheds fed of a spur in the mainhouse? and why have an Isolater at the back of the shed? you know that shed will be rammed soon and that will not be accessible think i would have placed at the front by the door above the double socket. thx keep up the good works
@tonywatson1412
@tonywatson1412 10 месяцев назад
Hi.tuff. is a tougher cable ...and there are some tidy cleats and banding out there...also makes a better seal in a stuffing gland...and can handle quite a knock...swa to shed .. changover to hi.tuff
@kevinhenryviii
@kevinhenryviii 10 месяцев назад
Best thing I ever got done electrical wise was to get an electrician to run power to my shed. 👍🏻 Made certain things so much easier.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Sounds great!
@davidbirrell8964
@davidbirrell8964 10 месяцев назад
Good job, well done. Sorry to read comments, everyone does the job differently. You went with the customer requirements.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Cheers
@bobcat9754
@bobcat9754 10 месяцев назад
The cust requirements are 2 S/O and a light and switch, they do not know how it should be installed or configured, the electrician then needs to make that judgement and quote. Dont lower your standards to do a cheap job.
@steviea6070
@steviea6070 10 месяцев назад
Good stuff. I would have definitely gone for conduit horizontal between sockets and chucked a saddle on each stud. Little bit more work but worth it.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Mmhh maybe if wanted from customer
@steviea6070
@steviea6070 9 месяцев назад
Maybe, just all not very nice and neat like you said with the cables flapping about. Also the iso switch for shed one looks faulty and hole drilled for swa is about 3 times too big, unless glory hole size was on the spec? Other than that, enjoying the content. Good effort
@Mike_5
@Mike_5 10 месяцев назад
Nice job here bringing the modern world of electricity to those sheds and let us all remember that people do some very strange things in sheds that are best done with the doors tightly closed 🙃
@gratis191988
@gratis191988 10 месяцев назад
Check out table D1 of the on site guide for cable spacings. Could have possibly inserted more 4x2 timber and clipped to that between the uprights or take the cable up along the top and down for each outlet. At the beginning we are all eager for work but i have found when someone wants a cheap jobs its best to walk away, either you're not happy with the work of the customer isn't.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Cool, thanks
@brianwood5220
@brianwood5220 10 месяцев назад
Everybody will do the job differently. If your happy it's done to the best of your ability and the customer is happy with the job. Then everyone's happy.
@g.williamswilliams8442
@g.williamswilliams8442 2 месяца назад
People are going to use those horizontal cables to hang stuf on,... poor cable support there Adam.
@jonathanhasmail
@jonathanhasmail 10 месяцев назад
A few observations, not criticisms at all, I’d have taken the supply for shed two out the back wall next to the feed in for shed one rather than running it up the inside corner, I’d have raised the floorboard panel up to cover the hole(s) through the shed wall as it’d look neater, then either used conduit for the sockets or clipped the t&e along the top of the wall and brought it down to each socket rather than stringing across (for the sake of a couple of extra metres of cable), my OCD would have made me put isolator for shed one on the left and finally, you should have used some flexicon somewhere, for old times sake 😂 Otherwise, a cracking job! 👍
@metproltd
@metproltd 10 месяцев назад
Really nice job Adam!
@shaynemacdonald3051
@shaynemacdonald3051 10 месяцев назад
Definitely should of talked the customer into going for conduit in the shed. Looks pretty awful the Twin and Earth on show. Why didn't you cover the SWA coming into the shed behind the back board?
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
So it’s accessible for future
@jamiemetcalf547
@jamiemetcalf547 10 месяцев назад
Come up and along the top bit of timber and then drop to to sockets so you can clip correctly and guarantee they are secure. Anything catches them cables they will get stretched or worse yanked out. Live and learn mate! You can't improve by getting it right all the time! Everyday is a learning day!
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Cheers
@thomasjw_7408
@thomasjw_7408 10 месяцев назад
Can you do a toolbag tour and maybe explain why you use what you do?
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Yeh I’ll look G doing this
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Look at
@kevinpaterson4859
@kevinpaterson4859 10 месяцев назад
Great job 👏 what brand are those back boxes?
@bobcat9754
@bobcat9754 10 месяцев назад
The best back boxes are Deta, They're ABS, 20 years garentee, the ones Adam used are plastic, probably appleby, which in that location won.t last a year.@@kevinpaterson4859
@thomasjw_7408
@thomasjw_7408 10 месяцев назад
@@AdamDunlopElectrical I’ve seen but would be interesting to see an updated version now you’ve qualified
@winnieowen4401
@winnieowen4401 10 месяцев назад
i always clip high level & drop down in conduit to sockets switches etc. kids can pull on them cables ? not your best work mate
@smoggydrones5664
@smoggydrones5664 9 месяцев назад
Totally agree but as a young lad he will learn better cable management. That’s the beauty of RU-vid video,s that he will get constructive criticism so his learning curve will be steeper
@anthonycampbell9807
@anthonycampbell9807 10 месяцев назад
I would have run the cables along the top studs and dropped them down to the sockets, don't like the look of it going across the walls.
@scottbeattie7394
@scottbeattie7394 10 месяцев назад
U probably strengthen the shed up putting them dwangs in4 the skt pal
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Ahah
@Subzero2151
@Subzero2151 9 месяцев назад
Loving the content Adam, our employer recently switched to verso fittings, what do you think of them ?
@AdamDunlopElectrical
@AdamDunlopElectrical 9 месяцев назад
Yea good I like em
@AndyK.1
@AndyK.1 10 месяцев назад
Dentist colour shade 😂
@Watsy
@Watsy 10 месяцев назад
Did you mean to not seal the hole?
@timprice5
@timprice5 10 месяцев назад
Nice little job there Adam! Any reason you didnt use one (or a couple of) LED battens in each shed? Would provide a better distribution of light and fits a bit more nicely on the beams. Even (heaven forbid) a couple of LAP items. Being in a shed, one of their IP65 battens are actually quite well designed. Personally i would have tried to get top and bottom entry consistent between each of those double sockets, one is up and one is down which looks a bit strange to me. Mind you it is just a shed so perhaps I am being picky!
@MartinE63
@MartinE63 10 месяцев назад
Sadly that install looks like poor DIY. T&E when run at that height is prone to damage such as from garden implements or just general occupancy.
@andysims4906
@andysims4906 9 месяцев назад
It is a DIY job
@bonaminhrasmey42
@bonaminhrasmey42 9 месяцев назад
❤where do you get the power from 😊
@simonthug7866
@simonthug7866 10 месяцев назад
Nice job, some times its Nothing u can do. However, cleen job mate
@bobcat9754
@bobcat9754 9 месяцев назад
but most of the time theres plenty
@thereal1006
@thereal1006 9 месяцев назад
All the gear no idea
@AGRElectrics
@AGRElectrics 9 месяцев назад
that verso RH switch tab has broken....
@mrrobot9538
@mrrobot9538 10 месяцев назад
This man has to much money, look at all them tools!
@bobcat9754
@bobcat9754 9 месяцев назад
He didnt buy them, he was given them because of Nick bundys channel
@bobcat9754
@bobcat9754 10 месяцев назад
why didn't you bring the two swa's through behind the backboard at the same level. If the customer told me not to use conduit or trunking, i wouldnt have done it. would you run twin and earth up someones wall in their living room. just because they wanted a cheap job. I'lld say its more vulnerable in a shed. Whats the maximum support spacings for 2.5mm run horizontally, you can ofcoarse lift the fence panel out and from the neigbours garden lift the cable off the ground and fix it properly.
@asherd101
@asherd101 10 месяцев назад
It’s a shed you nob, not somewhere they’re living in every day. If they don’t mind seeing the cables up to them.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Nothin wrong with what I did and I’d love to lift the fence however if I did I would be greated with the neighbours shed so no luck 🤣
@bobcat9754
@bobcat9754 10 месяцев назад
@@asherd101 you're clearly not an electrician, just because it's a shed doesn't mean it's exempt from regulations or common sense.
@asherd101
@asherd101 10 месяцев назад
@@bobcat9754 it’s double insulated and run through the joists no different to a loft, we’re in the real world he said he couldn’t get fixings in as the sheds too thin. Guessing in your loft all the cables are in galv tubes covered by afdds 😅 and I’m a spark an industrial one 👍👌
@JQ049
@JQ049 9 месяцев назад
What you think mate 6 or 8 inch ck cutters
@AdamDunlopElectrical
@AdamDunlopElectrical 9 месяцев назад
Think it’s the 180 ones I use
@johnspallen3132
@johnspallen3132 9 месяцев назад
❤ too many negative comments good tidy young spark the new Nick bundy ❤
@bobcat9754
@bobcat9754 9 месяцев назад
Don't see them as negative, the lad can do good work, but if everyone tells him he's the best thing since sliced bread, he'll never learn, now is the time he actually starts learning, he can only get better if he takes comments / suggestions onboard
@shaun30-3-mg9zs
@shaun30-3-mg9zs 10 месяцев назад
Great job Adam, nice and neat well done👍
@ADAMBRADY04
@ADAMBRADY04 10 месяцев назад
When I got my shed wired up sparky wouldn't let me use the none ip rated items I bought he told me it all has to be up rated and went ahead and fitted them
@bobcat9754
@bobcat9754 9 месяцев назад
was it actually a shed or an aviary, i can see your a male budgie
@ADAMBRADY04
@ADAMBRADY04 9 месяцев назад
​@@bobcat9754aviary has IP rated sockets switches lighting and sub main from house goes into aviary to garage board, however its my shed for storage I just wanted normal lap sockets installed had them all there for him to fit but he insisted it's got to be up ones as sheds can get wet in his words so persisted on more IP sockets
@foxsake_
@foxsake_ 10 месяцев назад
U taking on any apprentices?
@AndyK.1
@AndyK.1 10 месяцев назад
Don’t think I would want chipboard as my shed roof. When it gets wet. That’s it
@MartinE63
@MartinE63 10 месяцев назад
It’s OSB, as used in the structure of many buildings these days. If it’s the correct grade it’s fine.
@andysims4906
@andysims4906 9 месяцев назад
Most sheds are crap these days
@jcol1533
@jcol1533 10 месяцев назад
Nice 1… not a sparky but looks a good job to me
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Cheers I try ahah
@terrybutler1231
@terrybutler1231 9 месяцев назад
You need an apprentice to do all the dogsbody work 👌
@AdamDunlopElectrical
@AdamDunlopElectrical 9 месяцев назад
Ahah
@bullhurley-uv8ys
@bullhurley-uv8ys 10 месяцев назад
Lovely jubly
@michaeljarcher
@michaeljarcher 10 месяцев назад
Nothing wrong with Primart for a bargin, but just don't go ordering tools off Wish 🙂
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Very true!
@stevecraft00
@stevecraft00 10 месяцев назад
Those lights are identical to thorn lara lights. Everything about them. Must be rebadged.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
Ahah
@ef7480
@ef7480 10 месяцев назад
Exported PME?
@GeoB24
@GeoB24 10 месяцев назад
Doesnt matter if its wooden framed
@rlfvacslakenheath
@rlfvacslakenheath 10 месяцев назад
in a wooden shed with no extraneous parts no gas or water pme earthing is fine.
@travoltasbiplane1551
@travoltasbiplane1551 10 месяцев назад
Why does everyone wear gloves all the time now and never use a hand tool. It's bent.
@andysims4906
@andysims4906 9 месяцев назад
Because they have baby skin
@bobcat9754
@bobcat9754 9 месяцев назад
I think they come with baby powder inside@@andysims4906
@Sharron-Idol
@Sharron-Idol 10 месяцев назад
Great electrics. Using "obviously" as a filler word in almost every sentence isn't cool though.
@AdamDunlopElectrical
@AdamDunlopElectrical 10 месяцев назад
🤣
Далее
Mistakes Were Made And Lessons Learnt
17:13
Просмотров 19 тыс.
@HolyBaam ультанул в конце 🧨
00:34
Просмотров 192 тыс.
Doors Harpy Hare (Doors 2 Animation)
00:16
Просмотров 702 тыс.
Buying My Dream Van At 20 | Van Life
8:52
Просмотров 25 тыс.
DIY Guide To Wiring A Shed For Electricity
18:02
Просмотров 87 тыс.
I Could Have Died...
10:03
Просмотров 19 тыс.
CHEAP Electrician cost this customer £1000s💷
18:43
Просмотров 113 тыс.
250 Miles To Work In London! | Summer House Wiring
28:32
Van Vault Installation Into New Van | Van Build Ep 3
14:09