What is Knee point Voltage of current transformer| knee point voltage Calculations &Testing in Tamil 

Engineering in Tamil
Подписаться 6 тыс.
Просмотров 13 тыс.
50% 1

#Kneepointvoltage
#interviewquestions
#Electrical
The knee point voltage defined as the voltage at which a 10% increase in applied voltage increases the magnetizing current by 50% for voltages greater than the knee point, the magnetizing current considerably even for small increments in voltage across the secondary terminals

Опубликовано:

 

4 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 25   
@manikandan-lx6gr
@manikandan-lx6gr Год назад
Thank you sir.unga video explanation super sir🎉
@MTBZSebastian
@MTBZSebastian 11 месяцев назад
Clearly explained 🎉
@tamilchelvanramasamy8733
@tamilchelvanramasamy8733 10 месяцев назад
Lucidly explained. Thanks
@PrabakarRamakrishnan
@PrabakarRamakrishnan 6 месяцев назад
Hi boss, The fault current If mentioned in CT is 3kA.do we have to consider fault current of bus?
@senthilkumar-ss5yq
@senthilkumar-ss5yq 13 дней назад
Sir suppose we found knee point voltage less than Ct name plate details mentioned voltage what action need to take? CT should replace.
@SMMohan-fj5kn
@SMMohan-fj5kn Год назад
Super sir thank you very much sir, 50,50n and 51,51n enna nu konjam nalla explain panni oru video podukal sir
@nagarajvengatesh4401
@nagarajvengatesh4401 Год назад
Jii very usefull thank you
@venkatang4500
@venkatang4500 7 месяцев назад
very useful to us. tq.
@Engineering-in-tamil
@Engineering-in-tamil 7 месяцев назад
Thank you brother Keep support
@jims9916
@jims9916 2 месяца назад
what is the difference between VK and VK/2?
@himachalambalu3279
@himachalambalu3279 Год назад
Formula mentioned in the video is it right....? kindly check..... You have considered fault current as 4000A which is minimum ..... Even if you calculate fault current with trnsformer impednace minimum fault current would be 10kA or 15kA.... if you apply the same in the formulae then knee point voltage is very higher... can you check and confirm....
@rajkamal632
@rajkamal632 2 года назад
Bro cable Voltage drop calculation poduga
@Engineering-in-tamil
@Engineering-in-tamil 2 года назад
Entha cable voltage drop bro?
@rajkamal632
@rajkamal632 2 года назад
@@Engineering-in-tamil power cable bro
@gobikrishnagobi3702
@gobikrishnagobi3702 2 года назад
Superb
@Engineering-in-tamil
@Engineering-in-tamil 2 года назад
Thank you
@tiagoluisfrancisco9938
@tiagoluisfrancisco9938 2 месяца назад
During this test, should the CT make noise?
@nicatmehraliyev9224
@nicatmehraliyev9224 Год назад
Thanks. Super
@Engineering-in-tamil
@Engineering-in-tamil 11 месяцев назад
Thank you too!
@krishnaviyuga3696
@krishnaviyuga3696 Год назад
BRO, Neenga manual calculation panadhu 300CTR ku dan so, 165.3A varudhu as same as mentioned in name plate 165A. Correct dhana
@Engineering-in-tamil
@Engineering-in-tamil 11 месяцев назад
Current thaan bro
@dhanasekarsuberamani285
@dhanasekarsuberamani285 Год назад
Could you please explain the usage of knee point with details in practical
@sujinsviews66
@sujinsviews66 Месяц назад
Kit name ?
@user-zl2xp9hg1i
@user-zl2xp9hg1i 9 месяцев назад
Hi
@mangalthakur214
@mangalthakur214 Год назад
Hindi me bolo guru ji kya south logo hi btana hai
Далее
لدي بط عالق في أذني😰🐤👂
00:17
Просмотров 2,3 млн
ДО ВСТРЕЧИ НА РАЗГОНЕ
52:11
Просмотров 417 тыс.
What is a CT Burden ? Explained | TheElectricalGuy
11:59