Working of Zero Export and DGPV synchronization ? || What is DGPV Synchronization ? || How you will get faster returns from solar ? || How we can Run Solar with DG without Grid ?
#dgpv #zeroexport #RPP
Solar
Safest
Smarter
Saur urja
Biljli Kaise bachaye
Solar se Bijli Kaise Bachaye
Benefits of Installing solar
Profitable solar
Solar k Fayede
Solar Lagane k Fayade
MCB
MCCB
ACB
AJB
ACDB
DCDB
Lighting Arrester
walkway
cable Tray
Solar Panel
Solar Inverter
Solar Cable
AC Cable
Follow me on -
Telegram- t.me/+uVOzUWjDk0tiNTBl
LinkedIn- / raman-kumar-666436141
Facebook - / solarfacts-37057195372...
solar structures
Solar panel mounting structure
Solar mounting structure
acdb and dcdb for solar system
acdb box price
dcdb box for solar system
dcdb box price
long rail solar structure
mini rail for solar panels
mini rail solar structure
solar mounting structures
solar panel structure
solar structure
solar structure types
types of mounting structures for solar panels
types of solar mounting structure
types of solar structure
mounting structure for solar panels
mono rail solar structure
solar acdb box
solar acdb dcdb box
solar dcdb box
solar mini rail
standing seam solar structure
tilted solar structure
acdb box for solar
dcdb box for solar
Video link -
1. How solar zero export works.- lnkd.in/evPgfuj2
2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
6. How to check Current Transformers? - lnkd.in/eT5gc99e
7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
• Solar Power Plant Shad...
18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
30.What is Skin Effect ? // Why Skin effect happens in AC not in DC ? // Why current flow through surface of conductor ? -- lnkd.in/eHTtuFtK
For more information contact us 😊.
Name - Raman Kumar
Contact No- 9871073342

Опубликовано:

 

5 сен 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 103   
@rajeshmohan7881
@rajeshmohan7881 Месяц назад
Very very informative and rare topic. I was needing this information as am going to make DPR for 250 KWp on grid plant. Thank you very much.
@RahoulSubberwal
@RahoulSubberwal 2 месяца назад
Very interesting, and appropriate for a problem we are attempting to solve at present. The one point that was not discussed is if the load is less than half the installed Solar panel capacity, and this load is also variable in that it can be reduced to suit the output of the solar panels, then a low kw generator solution would work. Even if the generator occasionally trips, not having to run a large generator at 30% will result in significant saving on fuel. This scenario would work less well during the monsoon months! Thank you for making this video!
@shibu2935
@shibu2935 Год назад
Hello Raman...I am seeing your work for the first time...I didn't know you have a youtube channel ....it is so impressive that you've reached such professional levels in your carrier....your parents must be really proud of you .....a round of applause from my side 👏👏
@solarfacts4242
@solarfacts4242 Год назад
Thanks you 🙏🏻 May I know from where you are ?
@shibu2935
@shibu2935 Год назад
@@solarfacts4242 We are from Kanpur....we are neighbours in Tirwa ...Seema and family
@solarfacts4242
@solarfacts4242 Год назад
Thank you Mousi 🙏🏻
@Farhan_TruthLover
@Farhan_TruthLover Год назад
I have been longing to understand DG sync in detail in hindi. Thanks a lot Raman bhai. Masha Allah nice work. Keep us technically energised.
@solarfacts4242
@solarfacts4242 Год назад
Thank you
@ajeet.singh800
@ajeet.singh800 Год назад
प्रिय मैं आपका बहुत बहुत धन्यवाद दिल से करना चाहता हू ,खूबसूरत कॉन्सेप्ट
@solarfacts4242
@solarfacts4242 Год назад
Thank you sir
@user-tn9jl3ik2v
@user-tn9jl3ik2v 8 месяцев назад
thankyou so much sir for explaining in wonder full ways it is vary help full for me
@shubhamgodbole9836
@shubhamgodbole9836 4 месяца назад
Plese make vidio of actual connection Thank You
@talhazubair8306
@talhazubair8306 6 месяцев назад
Great knowledge sir❤
@maneeshkumarvishwakarma1193
@maneeshkumarvishwakarma1193 10 месяцев назад
Beautiful guide line sir👌🏽👌🏽
@solarfacts4242
@solarfacts4242 10 месяцев назад
Glad you liked it
@asadiqbalengineeringservic7680
@asadiqbalengineeringservic7680 6 месяцев назад
Hi how are you my dear friend I am Asad iqbal from Pakistan I have solar installer. Nice information for me
@zeeshanalikhan5167
@zeeshanalikhan5167 Год назад
Good concept explanation in very easy way...👍
@solarfacts4242
@solarfacts4242 Год назад
Thank you 😊
@riteshsingh5039
@riteshsingh5039 Год назад
Thanks Raman ji, your video content is excellent and informative. Nicely explained too 👍
@solarfacts4242
@solarfacts4242 Год назад
Thank you so much 😊
@PardeepKumar-gg6em
@PardeepKumar-gg6em Год назад
Good work Raman as always. Pardeep from Apex Solar Jaitu Punjab
@solarfacts4242
@solarfacts4242 Год назад
Thank you
@YadaYadaYadaYada
@YadaYadaYadaYada 8 месяцев назад
Excellent! Yes please do make a video on the DGPV Synchronisation box. Thanks
@pagladasu9305
@pagladasu9305 10 месяцев назад
Excellent explanation. Keep it up
@YadaYadaYadaYada
@YadaYadaYadaYada 8 месяцев назад
Great Job!!
@meharsingh4539
@meharsingh4539 8 месяцев назад
Good information
@marbombam4281
@marbombam4281 Год назад
Very informative indeed, keep doing 👍👍
@solarfacts4242
@solarfacts4242 Год назад
Thanks 🙏🏻
@irshadmahmood1827
@irshadmahmood1827 9 месяцев назад
Good explanation ❤
@SunilPatel-xg2rx
@SunilPatel-xg2rx Год назад
Knowledgeable content 👍
@solarfacts4242
@solarfacts4242 Год назад
Thank you 😊
@influx_engineering
@influx_engineering Год назад
very well explained
@solarfacts4242
@solarfacts4242 11 месяцев назад
Thank you 😊
@jyothiprakash599
@jyothiprakash599 Год назад
Excellent presentation, very well explained in detail 😊
@solarfacts4242
@solarfacts4242 Год назад
Glad it was helpful!
@sameermfaroor9856
@sameermfaroor9856 Год назад
Great lecturer
@solarfacts4242
@solarfacts4242 Год назад
thank you
@pallabdas2972
@pallabdas2972 7 месяцев назад
Could you please make a programme on installation procedure of dgpv synchornisation
@nirdeshsaini
@nirdeshsaini 4 месяца назад
Thank you. It's a beautiful video. Any ball park cost for a DG Synchronization for 100 KW system.
@ramsingpadol3309
@ramsingpadol3309 Год назад
Tnx u sir
@solarfacts4242
@solarfacts4242 Год назад
Thanks
@user-pi8iw3sk2k
@user-pi8iw3sk2k 2 месяца назад
I don’t know dgpv synchroniser, but there is 1 more technique. Called zero export feature, that’s it, that’s sufficient, let dg run at 30% come what may & after that let solar start producing, since it is sync w this new ref (dg) it will pump power to load & letting dg to not to raise its delivery, as solar start under performing, means it will not be able to cater the load abv 30%, so in that naturally dg will start pumping power to load till it’s 100%, & as solar starts gaining its capacity, it will start pumping in to the load & thence dg will start derating its capacity. Just remember after start of dg, on grid fail, we r simply maintaining the lower limit of its operation to 30%, and sw on zero export feature of solar. Rest is taken care, adaptively.
@Bhardwaj5
@Bhardwaj5 Год назад
Nice explanation sir, Ek or video Synchronisation device pe agar bataye jiski help se design kr Pau.
@solarfacts4242
@solarfacts4242 Год назад
Ok sure
@Govindsingh-xo7ov
@Govindsingh-xo7ov 11 месяцев назад
DG PV plant ka Synchronisation connections ka video banaye sir, please
@solarfacts4242
@solarfacts4242 11 месяцев назад
Sure sir Bahut jaldi i will make video on it
@siladityabhowmik8623
@siladityabhowmik8623 Год назад
Thank you for your educational video. Request you to make a video on SOLAR - DG- BATTERY BANK (LIFEPO4) Hybrid system. It will be better if you integrate windmill system also . Thank you .
@lalitpuri6071
@lalitpuri6071 Год назад
Thanks for the vedio, I have installed Solar in my Flat which is on Top Floor of the society, I have 3-Phase supply which is coming via Grid and society DG set via a Dual meter. Please let us know how can I use the Net meter in this case and shall I need to install DGPV
@solarfacts4242
@solarfacts4242 10 месяцев назад
You can do net metering if you are getting supply from the grid and in this case your solar connection should be separate from the DG
@usamaghauri8618
@usamaghauri8618 18 дней назад
Can we use ups instead of dg for reference in case of load shedding?
@MuhammadUmer-dp5eq
@MuhammadUmer-dp5eq 10 месяцев назад
Thank you so much, Brother. You have explained it very well. But I have a question in mind can we install a zero export device in place of the PV-GEN set when we turn ON the on-grid inverter with DG. As we install Zero export device then no Power will go towards DG.Can we do this thing?
@solarfacts4242
@solarfacts4242 10 месяцев назад
Zero export only insure that the power flow should not be to the grid
@MuhammadUmer-dp5eq
@MuhammadUmer-dp5eq 10 месяцев назад
@@solarfacts4242 not for DG?? because when our Generator turns on the Inverter Considers its reference and Starts its production as the inverter does not know the difference between Grid and DG?? Kindly give me a clear answer about this thing?? It's a humble request from my side
@siligurisolarstation2310
@siligurisolarstation2310 Год назад
Sir very good information give me zero xport divice installation please share with me
@solarfacts4242
@solarfacts4242 Год назад
ok will do
@muhammadrashid-up9no
@muhammadrashid-up9no Месяц назад
Agar DG line pr zero device lga le tu kya phir be DGPV ki zrort ho ge ?must replay
@shubhamdahiwale8657
@shubhamdahiwale8657 Год назад
Inverter ke components and circuit diagram ke uper video chahiye sir
@solarfacts4242
@solarfacts4242 Год назад
ok give me some time i will make one video on it
@reliablesolarenergy
@reliablesolarenergy 7 месяцев назад
How can DGPV system work in cold storage solar system? Is it advisable or not?
@badarabbas1035
@badarabbas1035 Год назад
Bai instrument capping ke bary or instrument scanl ke bare vedio bnao
@solarfacts4242
@solarfacts4242 Год назад
ok
@aabidbhat3816
@aabidbhat3816 13 дней назад
Helo Raman, thanks for the video. I have one question, in this case we have to install Zero export meter also to avoid the export when grid is not available. Please correct me
@solarfacts4242
@solarfacts4242 12 дней назад
No sir we will only generate the power which is required to run the load So extra power will not be generated, and export will not happen
@shahzadkhan9307
@shahzadkhan9307 Год назад
A SIR, Kindly make a vedio on DG PV sychronius Box we are waiting
@solarfacts4242
@solarfacts4242 Год назад
ok Sure
@dapakarswapnil3264
@dapakarswapnil3264 9 месяцев назад
Reverse current found in inverters due to DG , what is the reason
@MaheshPatel-sh9tq
@MaheshPatel-sh9tq Год назад
Home Invertor se refrance volt de ke solar Invertor ko kaise chla sakte hai
@solarfacts4242
@solarfacts4242 10 месяцев назад
Already there is a video please check my channel
@naeem.akram111
@naeem.akram111 Год назад
please make a video dgpv synchronization
@solarfacts4242
@solarfacts4242 Год назад
ok
@shashanksharma8443
@shashanksharma8443 Год назад
Hello sir, you are talking about refrence voltage so how reference voltage require for particular on grid inverter?
@solarfacts4242
@solarfacts4242 Год назад
because if grid is not available we can not export the power that's why reference voltage is required
@johnruben1444
@johnruben1444 10 месяцев назад
I am installing 3kw on-grid system in my apartment with zero export CT. In the basement we have a big DG which powers all flats (total 30) including common area and Lift. Mine is a single phase, do you propose DG PV system or should I disconnect the DG ? My electrician was telling he would pull a separate line for a kitchen point from DG (post DG disconnection in the basement to my flat) will it be feasible as I am not sure how on-grid inverter would react since it will be connected to my Mains. Please help.
@solarfacts4242
@solarfacts4242 10 месяцев назад
If you are not doing DG synchronisation please keep solar separate
@raginisingh5762
@raginisingh5762 Год назад
Please make video on DGPV synchronisation box also .
@solarfacts4242
@solarfacts4242 Год назад
Ok sure
@shahzadkhan9307
@shahzadkhan9307 Год назад
Please make vedio on dg box and switch gear.
@PratinChaudhari
@PratinChaudhari Год назад
Bhai.....banado dg-pv connection pe video🙏
@solarfacts4242
@solarfacts4242 Год назад
Ok sure
@rizwanjanu4204
@rizwanjanu4204 Год назад
Bahi ager solar panels ke cable ke sath main power 440 ke cable chalay to koi problem Hoti hai
@solarfacts4242
@solarfacts4242 Год назад
no but there should be a gap required as per current
@user-pi8iw3sk2k
@user-pi8iw3sk2k 2 месяца назад
Icelanding nahi ilanding spell as islanding
@user-uq4su4xh9o
@user-uq4su4xh9o 6 месяцев назад
Bahi 2 inverter ko parallel Kyu karty hai?
@Farhan_TruthLover
@Farhan_TruthLover Год назад
I have one doubt. What if DG is higher and Solar plant is lower in size? Eg. 200kv DG and 20KW solar
@solarfacts4242
@solarfacts4242 Год назад
In this my solar will start when after 60 Kw load
@prasadjoshianwikar2634
@prasadjoshianwikar2634 Год назад
What about PF correction at DG & PV load sharing at high/varying power demands?
@solarfacts4242
@solarfacts4242 Год назад
I will make one video on it
@barunkumar1984
@barunkumar1984 Год назад
​@@solarfacts4242if video is uploaded, please share link
@fahadmukhtar1124
@fahadmukhtar1124 Год назад
if the load is 20 kw suppose for whole day then will it effect diesel generator life ?
@solarfacts4242
@solarfacts4242 10 месяцев назад
That will affect in long term
@bhuvneshkumar912
@bhuvneshkumar912 Год назад
Sir meri site 1mw par MFM, DG par lga h or usse hi sync ho jata h . DGPV kyo
@solarfacts4242
@solarfacts4242 10 месяцев назад
Yes
@niteshgiri4650
@niteshgiri4650 Год назад
Pla send dc voltage drop calculation excel file ..
@solarfacts4242
@solarfacts4242 10 месяцев назад
Sure will make a video
@fahadmukhtar1124
@fahadmukhtar1124 Год назад
If the load is itself very low that is nearly 15% of Diesel generator then what? DG set will start to deteriorate or get itself damage?
@its_amir
@its_amir Год назад
Then there is no point to connect DGPV sync.
@fahadmukhtar1124
@fahadmukhtar1124 Год назад
@@its_amir There is no grid so DGPV always working in parallel .
@solarfacts4242
@solarfacts4242 10 месяцев назад
That will affect in long term
@sauravmodak507
@sauravmodak507 Год назад
Why make it complicated? Why can't the inverter cut grid during power out and run by itself.. Generation on shinewave is not so hard If it still needs reference..
@solarfacts4242
@solarfacts4242 Год назад
Because these inverters having anti-islanding feature