Hello bro, I am a wire erosion professional for 15 years. I have been dealing with technical service for the last 7 years, the robofil series and charmilles are a beautiful machine and they are very popular in Turkey, but they can cause ridiculous malfunctions, and I used sodick in wire erosion :)
Hello friend, when I finished the maintenance on the lower head there was a problem the wire became vibrating and the machine stopped and it appeared on the screen ( wire broken) even though the wire is not broken
@@whatsonh5737 help me bro , Power value increases wire is broken what next bro ?but power value 10 to decreased run the wire normally not broken help me
I think they say these parts shouldn't be cleaned with anything but water, but I sometimes soak some parts in Janitol Altrans (Acidic cleaner) 🤭. Takes the dirt right off, but you have to rinse thoroughly. You get a sticky residue if you don't.
You just have to bleed the system. There is 2 small screen by the contact guide. Losses it while feed is on. Wait until all air purges out. And retight.
@@humanfactors143 indeed I always try turning on rollers to help evacuate more air, but still after doing maintenance I receive lower pressure alarm which forces me to clean the Hydrtrex filter cartridge in the back or change in when it’s still has plenty of life left