Worcester NO IGNITION. Gas valve Reset/ Adjust & Fine Tune. Detailed/ Step by step, Fault Finding. 

F Raj
Подписаться 1,7 тыс.
Просмотров 8 тыс.
50% 1

Опубликовано:

 

6 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 33   
@all4heatinggaslimited40
@all4heatinggaslimited40 2 месяца назад
This is the best video I have ever seen better than a trainer. Very well explained step by step backed up by evidence and pictures. Sound quality is excellent You are a Legend ❤❤❤❤
@BoilerMend
@BoilerMend 2 месяца назад
Wow.. Very kind words 🤩. Made my day 😎👍
@DD-eh9cp
@DD-eh9cp 8 месяцев назад
Good presenter. Very clear presentation.
@waynetraish1895
@waynetraish1895 3 месяца назад
Very helpful video, explained really well and clearly 👍
@BoilerMend
@BoilerMend 3 месяца назад
Thanks 😎👍
@chohanchohan8208
@chohanchohan8208 Год назад
Better than WBosch training I can assure you - thank PaaG
@BoilerMend
@BoilerMend Год назад
Thanks. Very kind 😌
@Carl-re6zb
@Carl-re6zb Год назад
Nice one Raj... Also if the adjustments on the valves don't work you need to check the bearing plate washer..
@melvinevans9981
@melvinevans9981 Год назад
Love your work as always, mate. You are one of the best on RU-vid I watch. Keep on making em
@benson16100
@benson16100 9 месяцев назад
Quality video 👍
@BoilerMend
@BoilerMend 9 месяцев назад
Thank you 🫶
@yodhayyodhay
@yodhayyodhay Месяц назад
Brilliant teacher
@BoilerMend
@BoilerMend Месяц назад
Thanks 😊👍
@lucanspittle8213
@lucanspittle8213 6 месяцев назад
I had same problem However British Gas had been servicing the boiler 7 years prior. Never taken the case off. The electrodes worn out, gasket on heat cell disintegrated ! The top baffle had blown! And bottom baffle stuck ! Also reset gas valve too. Same process as yours just about adjusting gas valve to suit But we’re putting a new heat cell in next
@BoilerMend
@BoilerMend 5 месяцев назад
Unfortunately big companies don't live upto their names when it comes to standard of work. If the work is carried out according to correct procedures. Maintenance would be easy and a lot less hassle. BTW. Did you have that main hx put in?
@ClaudioLorente
@ClaudioLorente 7 месяцев назад
very well explained. Well done. thanks
@BoilerMend
@BoilerMend 7 месяцев назад
Thank you 🫶
@martinwright7093
@martinwright7093 Год назад
Nice one.. had to do this a few times, keeping the burner lit on minimum can be tricky, especially on the 12 and 15KW models.
@QuransFaizan
@QuransFaizan 10 месяцев назад
12 n 15kw ones can be a pain to adjust
@davidproctor6359
@davidproctor6359 3 месяца назад
brilliance
@BoilerMend
@BoilerMend 3 месяца назад
Thank you 👍
@jameswilson2899
@jameswilson2899 10 месяцев назад
Great video
@BoilerMend
@BoilerMend 10 месяцев назад
Thanks 👍
@fidamohammed9371
@fidamohammed9371 2 месяца назад
Hi F Raj brilleant video now we know how to turn minnimum and maximum totally off and 3 and half turn and 2 and half turn for minnimum to atleast keep the boiler going Do u know how to do it with vaillant and baxi 2 which flue analyser would u recomend not happy with anton need to buy different one Thaanks
@BoilerMend
@BoilerMend 2 месяца назад
Hi. Thanks for your kind message👍. I've tried this, on Vaillant's EcoFit pure. I'll try and make a video sometime. Haven't tried on other models or Baxi. I've mostly used Anton and worked fine for me. Have used Kane Abalyzer's older models. Does the job well but was chunky. Not sure about newer models.
@seanb-ol3up
@seanb-ol3up 11 дней назад
If the co2 doesn't come within range say its at 8.8% and wont adjust to 9.8% is the gas valve faulty?
@BoilerMend
@BoilerMend 11 дней назад
If you can't bring CO², to the Manufacturer's recommended limit. Before declaring the Gas Valve faulty, check the negative fan pressure/ fan pull as well as the inlet working Gas pressure at Max Chimney Sweep Mode. If these are as recommended. But still, the CO² readings are not correctly adjustable, than the Gas valve may very well be faulty.
@seanb-ol3up
@seanb-ol3up 11 дней назад
@@BoilerMend thank you
@mikearthur2586
@mikearthur2586 11 месяцев назад
Can I ask where you got the 3.5 turns and the 2.5 factory reset information from please ?
@BoilerMend
@BoilerMend 11 месяцев назад
Hi. It is in the little document, shown in the video. Time is 12min 44seconds. This document usually comes with a new gas valve for several worcester models.
@seanb-ol3up
@seanb-ol3up 3 месяца назад
Was at one of these today greenstar 15ri the data badge said co2 9.6%/8.6% the only manual I could find said 9.8%/9.2% so which do I go by? Any info by anyone would be greatful thanks
@BoilerMend
@BoilerMend 3 месяца назад
Data badge is on the appliance. I would say go with that
@seanb-ol3up
@seanb-ol3up 11 дней назад
If the co2 on the gas doesn't adjust within range is it a faulty gas valve? Say co2 is at 8.8% high fire and won't adjust to 9.8%
Далее
Servicing, fault finding Worcester Bosch
32:16
Просмотров 13 тыс.
PUBG MOBILE | Metro Royale: Fun Moments #4
00:16
Просмотров 173 тыс.
How to check a Diverter Motor without a multimeter
3:38
Worcester Bosch CDI full service
6:59
Просмотров 39 тыс.