Тёмный

Your Sump Pit Is Killing You 

Radon Man
Подписаться 1,2 тыс.
Просмотров 82 тыс.
50% 1

Shockingly high levels of radon in this home were coming primarily from the sump pit.
In this video I'll show you how we took care of it. I'll be showcasing the Hyper-Drain sump pit covering system sold by Radon Away. Hope it helps and Thanks for watching!
Here is a link to the radon monitor shown in this video--a.co/d/4GL9Vs8

Опубликовано:

 

4 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 80   
@beauchampfrancois151
@beauchampfrancois151 Год назад
I've been working and living in my basement for 7 years now. My radon readings are around 150-175 (Bq/me3), even in the bathroom nearby (separated by an inside wall) my open unused sump pit. When I close my bathroom door my readings go up to 450-500 within two hours. Your video is the exact thing I was looking for... you nailed it. Thank you.
@dwaynejohnson6277
@dwaynejohnson6277 9 месяцев назад
Question is: is sealing the sump enough, or it must also have a fan that draws from sump and blows outside?
@chadvansickle1318
@chadvansickle1318 Месяц назад
The fan and piping to vent outside is absolutely necessary!​@@dwaynejohnson6277
@patty109109
@patty109109 Месяц назад
@@dwaynejohnson6277you need to test-imo it’s unlikely to be enough.
@talkalot80
@talkalot80 3 года назад
Thank you for making this video. I wasn't sure WHY my sump pump was sealed in a new home. I thought it was for looks because it's a finished basement. Wish they would have done a clear lid like you did instead of a black one. I'm trying to investigate why it never turns on
@ttables2007
@ttables2007 Год назад
Awesome video and thank you for sharing your wisdom. Truly helpful!
@radonman6800
@radonman6800 Год назад
Glad it was of help to you. Thank you for taking the time to say so. It means a lot.😀
@geoffjenkins4633
@geoffjenkins4633 2 года назад
I'm currently finishing up a sump install in my basement (first time doing it, not a pro). For allowing water in but keeping radon gas out, I considered devices like the Hi-Perdrain, but they all have low flow rates. I also considered devices that are essentially rubber socks with high shape memory, but again, the flow rate is so low. So my thinking is that I'll make a p-trap on the bottom of the lid. The only issue with that is with traps on low use devices, you have to make sure to top that water up on occasion. I have a dehumidifier that drains through a hose, and I'm just going to put that hose near that drain. Just my current thinking. Thanks for making videos and being honest about your skill level, don't fret the people who choose to be negative rather than keep scrolling.
@radonman6800
@radonman6800 2 года назад
Hi Geoff. Thanks for your comments! Hope I'm not too late. I recall a situation where a p trap did not go well and it's in the video link at the bottom. However, I believe that I was using a high suction fan. Nevertheless it caused gurgling from a floor drain. Best of luck to you and your project. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-QEgyI6rdMeA.html
@geoffjenkins4633
@geoffjenkins4633 2 года назад
@@radonman6800 Not too late, and interesting! My approach is inspired by the link below. My p-trap will be on the sump basin lid itself, and the sump is ~40 ft from my radon fan. Hopefully that will allow enough room so as to not be an issue. The drain on the basin lid is not necessarily a "must have" for us, so if it's an issue, I'll just remove it for the time being haha. Thanks, man. Cheers
@geoffjenkins4633
@geoffjenkins4633 2 года назад
andrewwinkel.com/tag/sump-hole/
@radonman6800
@radonman6800 2 года назад
Good luck Geoff!
@johntambascio3971
@johntambascio3971 8 месяцев назад
home inspector here, 1 in 10 are hot in the NE test please and test again if you change your roof windows insulate finish areas change grade and if not every three years,
@timkostka
@timkostka 3 года назад
These videos are very helpful and well done. Thank you for putting them out!
@chadvansickle1318
@chadvansickle1318 Месяц назад
Hi Scott, thank you for your videos. I'm planning to install my own system drawing from my sump pit. My pit is close to a bathroom and it would be fairly easy to tie into my homes sewer vent and avoid all of the unsightly pipes and fan, etc on the outside of the home. I know it probably wouldn't meet code but dont care about that. My question then is there any reason why this would be ok or not ok? I would put the fan either in the attic or in the utility room where it would be easier to make sure it is functioning properly. Thanks.
@ScottRGarcia123
@ScottRGarcia123 2 года назад
Is there a shorten version of this video that gets straight to the dry sump pit point? Not sure why Gary Busey showed up.
@TheBoomtown4
@TheBoomtown4 3 года назад
CAUTION!!! You’re creating a negative air pressure by not sealing the discharge pipes to the lid. Also very important to pay attention to other cracks and conduit that can pull air from the room/house. If a natural draft appliance is located in the house it can and often does spill carbon monoxide into the house rather than venting properly via buoyancy/stack effect. Potentially fatal oversight. Looks like electric hwh in this circumstance but diy’ers can get very sick/die if they don’t know what they’re doing and follow this method verbatim.
@djmcnamer7159
@djmcnamer7159 9 месяцев назад
I like this input. It would be wise to have a air balance done with systems running to verify one is not attacking the other. Most areas have a energy cooperative that can help. Range hoods, Gas dryer vents and a furnace can back draft. Making sure the lid is rated for radon mitigation is a first thing. Cracks in the slab and cement floor that meets the walls need to be sealed off. If the basement slab is sealed 100% and the lid rated for this. the system will create suction and deems the house safe.
@kaltrex9465
@kaltrex9465 7 месяцев назад
Do you mean don’t have any open gaps under the lid Above? What do you think it means if the discharge water is golden color? Rust or bacteria and how to clear it? My sump pump is just touching the ground under the foundation, that’s bad? I’m thinking of putting a Home Depot bucket in there and drilling holes on the sides to reduce earthy substances.
@TheBoomtown4
@TheBoomtown4 7 месяцев назад
@@kaltrex9465 yeah, it all needs to be sealed from the suction point, lest the ambient air in the home be exposed to the suction. The above comment from @djmcnamer7159 makes a good point about sealing up cracks in the foundation for example. If you had a cracked slab, the vacuum just take path of least resistance and just pull air from the ambient air in the basement creating a vacuum (negative air pressure) which would pull products of combustion (carbon monoxide CO) from your natural draft (hot water heater potentially) appliances. It would also decrease the amount of suction we could apply to the sub slab. But yeah, lit sealed for sure.
@BitmappedWV
@BitmappedWV Год назад
I’ve never seen a sump pump discharge into corrugated pipe before.
@doug4772
@doug4772 2 года назад
Why not just use the updated sump pit dome lids made for radon fans and sump plumbing? That's what I did at my house.
@dprofessor12
@dprofessor12 3 года назад
Radon systems are supposed to be sealed as tight as possible. Why didn't you seal around the 2" pipe you installed in the pit cover? It won't draw as good as it should unless the slab corners,grooves and pit are sealed as tight as possible.
@TheBoomtown4
@TheBoomtown4 3 года назад
In addition to not drawing under the sub slab this method can also create a negative air pressure sucking gas appliance exhaust/carbon monoxide into house.
@buckeyevs
@buckeyevs 2 месяца назад
He stated in the video that the sump hose still needed to be repaired/replaced. This isn't a finished install as the seal would be broken in short time if he did.
@radonman6800
@radonman6800 2 года назад
Several folks have requested a link to where I purchased the lid. Here it is--> www.radonaway.com/20-clear-sump-cover-567? However, Radon Away only sells to Radon Mitigators. Nevertheless, it's a place to start. Thanks for watching. 😀
@WilliamMcConnell-g1j
@WilliamMcConnell-g1j 8 месяцев назад
These videos are helpful.. Thanks. Just curious why you wouldn't purchase a small sump pump tube knowing that it is split and leaking. (charge it to the owner?) Also wondering why you would not seal the hole where the Radon exhaust tube goes through the new lid that you purchased. You were meticulous when installing the piece to the new lid that allows water to go into the sump pump pit but it does not allow air to escape yet you are allowing 1/2 gap between the lid and exhaust tube.
@donreinholz8121
@donreinholz8121 3 года назад
Hey Scott, I thought most radon mitigation seal up the cover and fittings so it draws radon from under the slab better than from the room above. How much do they cost? I will go to their website and check.
@nebulousJames12345
@nebulousJames12345 3 года назад
rip all that conditioned air :(
@radonman6800
@radonman6800 3 года назад
Hi Don, I get mine from Radon Away. However they only seem to sell to Radon Pro's. I'm sure Google or Amazon will get you there. 😀
@matthewlewellen5219
@matthewlewellen5219 3 года назад
Don jackal radon cap on Amazon 75 bucks seals for all different sizes, cap gasket, stainless hardware, I would not use another cover system
@mleofc
@mleofc 8 месяцев назад
When you dig the clay in the old Houses. How much are the radon levels before and after?
@russell2449
@russell2449 3 года назад
Nice job, so that 2" ties into a 4" which also has two other areas it's pulling from, one's the foundation but what area is that tee pulling from (just curious). I really enjoy your videos and as someone who used to be a plumber many moons ago, and looking to get out of my current career, this looks like it could be in my wheelhouse ;?)
@PopaZit
@PopaZit 2 года назад
Why would you not seal the sump discharge hose to the lid properly, and why would you not go the extra mile to replace the sump discharge hose for the customer?
@radonman6800
@radonman6800 2 года назад
because it it was necessary to do plumbing work at the sump pump beneath the lid (which needed to be removed after I made this video). Thanks for watching. 😀
@PopaZit
@PopaZit 2 года назад
@@radonman6800 I need to apologize for my overly critical comment, it was not necessary and I apologize. You are working hard to put out quality content to help people and I appreciate your hard work. So thank you.
@radonman6800
@radonman6800 2 года назад
No problem, Ken. I appreciate that and am glad to have you watching.
@dariuslavy3913
@dariuslavy3913 8 месяцев назад
@@PopaZit From the comments and the video, he did not make this clear. I thought he was just going to let it ride.
@jerbo1978
@jerbo1978 7 месяцев назад
He made it clear in the video by saying the pipe was cracked ​@@dariuslavy3913
@christmasbarn55
@christmasbarn55 9 месяцев назад
RU-vid algorithms popped your video in my feed or whatever….intuition…..very possibly….because radon has been on my mind lately! I subscribed because you are great, informative, so informative I’m scared now 😳. Mind if I ask questions? 1) where can I buy a thingamajiggy to test the levels. The thing the local DEHEC sent me was a level 4. I can’t recall if that was before or after we had a sump pump put in 😱 2) we do have a lid on sump pump much nicer than that ugly black thing, so I will look into buying the lid you used, I liked that you can see inside the pit! 3) when you say I’m dying…I live in the basement I have dry eyes, my dog has dry eyes, I sneeze like crazy pretty much every day. I could say I’m pretty fatigued but I don’t know if it’s not due to chronic low back & spinal pain. 4) am I classified as one foot in the grave, other foot 🦶🏼 on a banana 🍌 peel? Again thank you for making this video 3 years ago, which I know I was searching 3 yrs. ago RU-vid come on man! Thank you, hope you are still RU-vid ‘ing
@radonman6800
@radonman6800 9 месяцев назад
Here is a link to the radon monitor shown in this video--a.co/d/4GL9Vs8 Thanks for the kind words, Endora. I wish you lots of luck resolving your health issues.
@nostalgia46
@nostalgia46 3 месяца назад
You sure it was radon on your mind and not Georgia?
@LindaHolmes-i2w
@LindaHolmes-i2w Месяц назад
Tell me why my air vent becomes clogged up on my sump pump
@bobcaygeon975
@bobcaygeon975 24 дня назад
raise pump up 12-16" on a concrete block
@mediumsizedm
@mediumsizedm 2 года назад
A lotta talk, a lotta shortcuts, a lotta guesswork. Notta pro.
@matthewlewellen5219
@matthewlewellen5219 3 года назад
That plexiglas cover is definitely not airtight.
@sethmoeckel7853
@sethmoeckel7853 2 года назад
Not a fan of the lid choice here. Would be way too easy to crack if stepped on and doesn't seem to have all that great of a seal. Better seal would likely mean lower numbers.
@wysiwyg654
@wysiwyg654 3 года назад
If you had a water softener that drained to that sump pit, how would you handle it? I have a similar setup as shown in your video and would like to install a Tee fitting on my radon exhaust pipe (about 2 feet above the sump cover) and put a trap and standpipe for the water softener to discharge into. This would allow me to maintain the vacuum seal on the sump pit (with the trap) yet still meet the code requirements of having an air gap for the water softener discharge. Does this sound like a reasonable approach to you?
@radonman6800
@radonman6800 3 года назад
I would use the sump lid shown in this video that equipped with the Hyper Drain and route the discharge line to that. The strainer is plastic so you could notch out a section to route the tube into it or put a 90 right on top of it. Thanks for watching!
@wysiwyg654
@wysiwyg654 3 года назад
@@radonman6800 Thanks for the suggestion! Have you ever seen a radon exhaust pipe from a sump pit double as a drain pipe for a standpipe with a trap? I'm trying to think of reasons this wouldn't be a workable solution that would be less prone to failure over time as compared to a mechanical device like the Hyper drain.
@naturalhealing9970
@naturalhealing9970 2 года назад
Can you post a link of where we can get that lid?
@radonman6800
@radonman6800 2 года назад
Hi Natural Healing. Here it is -->www.radonaway.com/20-clear-sump-cover-567? However, Radon Away only sells to Radon Mitigators... but it's a place to start. Thanks for watching. 😀
@chrisp3193
@chrisp3193 2 года назад
Could you leave links where to buy these parts?
@radonman6800
@radonman6800 2 года назад
you got it😀 www.radonaway.com/products/waterproofing-crawlspace/sales-kit-sump-20-clear-10-pack.php
@webmoore4353
@webmoore4353 6 месяцев назад
I thought over 4.0 required mitigation…
@Jeff-ik3hn
@Jeff-ik3hn 3 года назад
Where can I buy a sump pit cover like the one you used ?
@radonman6800
@radonman6800 3 года назад
Hi Jeff, I get them from Radon Away but they only sell to mitigators- so I'd begin by Googling sump pit lids and Hyper Drain, etc. Ebay, Amazon, etc. Good luck!
@matthewlewellen5219
@matthewlewellen5219 3 года назад
Jeff get a jackal radon mitigation lid off Amazon. Comes with a selection of seals and gaskets and seals up great. New model Ds have a plexiglass access hole to check your floats or perform maintenance. If you are going to do it do it right. That plexiglass cover was junk and in no way was it airtight completely defeating the purpose of the vacuum circuit. That thing was drawing conditioned air into the pit
@Arctictwist
@Arctictwist Год назад
If i dont currently have a radon problem, will digging a sump pit cause one?
@radonman6800
@radonman6800 Год назад
Hi Ken. Long explanation short- the only way to know your radon levels is to measure or monitor them. Here is the link to the monitor I used in this video. ----a.co/d/4GL9Vs8. Here is a link to one short term test kit ---a.co/d/7j7akLl
@Steve-Chicago
@Steve-Chicago 9 месяцев назад
Too much moving causes headache.
@anitadavis1395
@anitadavis1395 3 года назад
This fella’ may have some good advice, but, unfortunately, his videotaping was so dizzying, annoying, and distracting that I bailed within 4 minutes of starting/watching the video. I would suggest (to him) that he puts a little more effort into his videotaping techniques/skills so as not to lose potential viewers, like me. Just sayin’.🤷🏻‍♀️
@03056932
@03056932 Год назад
ok boomer
@doitbyyourself66
@doitbyyourself66 3 года назад
U did a lil, and u talked too much The cam is on ur face more than on the work u R. Doing
@lawrencemeyers1212
@lawrencemeyers1212 2 года назад
This is to funny to watch
@manjushreetsl2531
@manjushreetsl2531 Год назад
3:09
@dfristoe5524
@dfristoe5524 7 месяцев назад
Raydon is a scam! Don't fall for it people
@david94sc
@david94sc 25 дней назад
Radon mitigation is a scam
@brians.5434
@brians.5434 2 года назад
Looks like a hack job
@turbopower130
@turbopower130 Год назад
Radon is a scapegoat to make money. When was the last time you heard od a "radon" related death/cancer? It's a fake market
@scottreid4698
@scottreid4698 9 месяцев назад
Love the chin diaper.why bother.?
@farukatasever2933
@farukatasever2933 8 месяцев назад
Why is that brick in the first pit?
@turbopower130
@turbopower130 Год назад
People who believe in radon and pay for "mitigation" are the same people who wear a mask in their car when they are the only person in the car. Props for you making money on the retired 👍
@baboon_baboon_baboon
@baboon_baboon_baboon 8 месяцев назад
People actually get cancer from radon though.
Далее
Sump Pump Running But Not Pumping Out Water | 3 Fixes
14:41
Mike Holmes on Radon
8:56
Просмотров 558 тыс.
PERFECT PITCH FILTER.. (CR7 EDITION) 🙈😅
00:21
Просмотров 3,9 млн
БАГ ЕЩЕ РАБОТАЕТ?
00:26
Просмотров 270 тыс.
6 Things Sump Pump Owners NEED to Know
8:07
Просмотров 1,2 млн
TRIPLE Safe Sump Pump System Installation
14:05
Просмотров 463 тыс.
How to Hotrod a Radon Mitigation System (Badass Mix)
12:32
Radon:  What is it?  How to Get Rid of It
6:32
Просмотров 465 тыс.
How To Install A Sump Pump Pit
27:32
Просмотров 809 тыс.
How to install a sump pump pit the right way!
8:09
Просмотров 55 тыс.
8 Tips All Sump Pump Owners Need to Know
10:07
Просмотров 113 тыс.
How To Install Your Own Radon Reduction System
8:54
Просмотров 163 тыс.
PERFECT PITCH FILTER.. (CR7 EDITION) 🙈😅
00:21
Просмотров 3,9 млн