My Name is jumbe from Zambia,I have liked. Your explanation on the generator wiring. I am asking for the circut diagrams for catapilllar Olympia generator .I asking for two drawings how to change the wiring from power warzad 1.1 to deepsea controller . Your support will be highly appreciated
Ser meron kami d6r cat bulldozer mag andar Naman xa sir tapos mamatay xa mga Isang minoto dati nawala lng Yung rpm nya Hanggang mag xa sandali tapos mamatay na
I dont understand sir no right swing and left swing what do you mean continuous swing if not swing left and right, if you wanted to say is just no swing left and right, if there is swing brake solenoid check it, or try to heard the the load sound of swing meaning swing brake is not work or no power supply while you are trying to swing at any direction
I had a problem with the pressure or something, I can't understand, raise the big arrow up, start pulling the small one towards you, and the big one stopped.. komatsu 210LC
Bro check the hydraulic pump, at the top of pump small size of plug, that's for ls and epc, and the main pressure you will found the plug where the main pipe high pressure is attached
Hello sir some function of hydraulic system its working or not ,if not meaning maybe do you have problem on ppc lock, but if some function is working I think you should have to check hydraulic pressure and need to get high pressure at arround 350br
Sir good day,komatsu pc200-8,nagpalit npo ako ng bagong solenoid na tatlo s may main pump,ok n sana kaya lng pag sinagad ang stick parang mamamatay sya,tnx for reply
@@caterpillarjhunhunk sinubukan ko narin po sinupplyan ng 24 volts yung tattlo ng sabay ginamitan ko po ng relay,pati yung dalawang solenoid s may control valve sinuplayan ko po ng 24,ganun parin po,maraming salamat po s mga reply
Ang pinagtataka ko pa sir pag tinggal o ung solenoid nkakakareading ako ng 24 pero pag ikinabit ko n yung solenoid ang reading naging 5 or 6 nlng,normal lng po b yun? Kung kaya nagwiring ako ng mga bagong supply ng mga solenoid,
@@costobodo79 pwede yan, kung bago p, deritso kabit, but kung luma n pero ok p nag coil, buksan mo nlang at e check mo ang laman lood make it sure n freely moving yung maliit n spool nya.
@@caterpillarjhunhunk30 matapos mag start tapos namamatay subra usok nya itim ganon ng ganon .pag uminit na sya deritso na andar nya pero antagal umistart
Galing mo talaga idol.... Sana makasama ako sayo sa trouble shooting for excavator... Wla pa akong alam sa ganyan idol. Saang bansa ka pla jan kabayan?