Motive Automation introduces itself as one of the fast-growing Engineering Firms such as industrial automation and A-Z Electrical Solution providers. We also provide Software Hardware services for SCADA (Web-PC) PLC, HMI, VFD, SERVO, and all kinds of panels (Motor control, HT, LT, PFI). Besides Motive Hitech Bazar is a property of Motive automation.
Motive Automation was established in 2012 as an Industrial automation service and competency-based Industrial Automation PLC, SCADA, IIOT training provider, due to the changing built environment and the growing needs of our clients; it became necessary to broaden the services that could be provided by Motive automation, so as to offer multi-disciplinary Industrial automation training, & Industrial automation equipment installation & commission. Motive Automation has added to their service by Integrating hardware and software applications.
Very good class, it's a shame I couldn't get your translation, I hope you can do a PID control class with dvp06xa soon, but I have a question, is it possible to make the settings directly in the option above, third icon, on the right, going to auxiliary configuration of the module extension and doing all the configuration there of what you want current or voltage? Thanks
The digital raw value of a PLC (Programmable Logic Controller) analog input refers to the raw binary or digital data obtained from the analog-to-digital converter (ADC) circuitry within the PLC. This raw value is typically a numerical representation of the voltage or current level measured by the analog input channel. PLCs often use a range of values, such as 0-4095 for a 12-bit ADC, to represent the analog input signal. The actual voltage or current level is converted into a digital value within this range. This digital raw value can then be further processed, scaled, or used in control algorithms within the PLC program. For example, if the analog input voltage range is 0-10 volts and the PLC ADC has a resolution of 12 bits, the digital raw value could range from 0 to 4095, where 0 represents 0 volts and 4095 represents 10 volts. The digital raw value of a PLC analog input or output depends on several factors: Analog-to-Digital Converter (ADC) Resolution: The resolution of the ADC determines the number of digital steps or values available to represent the analog signal. For example, a 12-bit ADC can represent the analog signal with 2^12 (4096) digital steps. Signal Range: The range of the analog input or output signal is also important. For instance, if the analog input signal ranges from 0 to 10 volts, and the ADC is 12-bit, each step would represent approximately 10vdc or 20mA 4096 4096 10 volts. Scaling: PLCs often allow for scaling of analog signals. This means that the raw digital value obtained from the ADC can be mapped to a different range of values, such as engineering units (e.g., degrees Celsius, pressure in psi, etc.). Without specific details about the PLC model, the resolution of the ADC, and the scaling applied, it's challenging to provide an exact digital raw value for an analog input or output. However, once these details are known, it's straightforward to calculate or interpret the digital raw value.
BONJOUR J AI ESSAYER DE TELECHARGER WINCC SMART SUR VOTRE SITEWEB MAIS J AI TROUVER WINCC FLEXIBLE 2008. J AI TROUVER WINCC SMART V2 ET J AI SUIS TOUT LES ETAPS D'installations mais je n ai pas reussi . quece soit sur windows 7 ou windows 10. svp j ai besoin de votre support
Hi referring to this installation video of this software. I did all this procedure and when I go to install it shows that I need to configure the region if I did it according to the video. Could you please let me know what version of your windows you have. My windows and windows 11 pro version 21H2, thank you.
Thank you for the nice video. I have some questions. How connect or upload program Tia-portal to HMI. I want to know the details. Could you provide those steps or details? Thanks, in advance.
Hello Sir.... In Delta (ISP SOFTWARE) ... There is problem while download to PLC option Problem is i.e.... connecting machine type is not consistent If i click on 'ok' ......?? Then show ...... Not support for current model type ...... Sir plz help....
Sir I'm selecting these all type of plc ., Then run,, ,,,,,but it is not run..... And error come that is =( not support for current model type or firmware version ) ..... For ------ DVP Simulator .... which type of plc type select ...
@@MotiveAutomation-PLC-SCADA sir physical hardware nhi hy . Without any physical plc which option is the best for no plc. Only program sikhne k liye konsa option select kre...
@@shersingh1423 Bhai this very little problem... 1 st you go to COMMGR ->click on Add -> give driver name -> click on connection setup to select type -- DVP Simulator after .. --> click on device setting --> select EH2/SV/Old Series ......& Then click on OK ...& START