Тёмный
AccessToPower
AccessToPower
AccessToPower
Подписаться
#accesstopower
This is the RU-vid Channel of Access Electric in Modesto California.
We are committed to continuing education for electricians both in Electrical Knowlege and Electrical Safety.

We also will be featuring and promoting the newest products in the electrical industry and providing lots of useful information for electricians wanting to stay abreast of what are the latest products and developments in the electrical field.

Videos are being added all the time, so please like, subscribe and click the bell to be notified of all upcoming videos.

If there is a topic you would like covered, leave a comment and we will try to address your request.

You can learn more about Access Electric by visiting our website www.accesstopower.com. We also update our blog on a regular basis, so for the latest news or articles from us you can visit our blog at www.accesstopower.com/blog
Starting a VFD with 2-wire Start
7:08
4 года назад
Calculating Voltage Drop
17:00
5 лет назад
Lamar Tool & Die
20:07
5 лет назад
Conduit Bending: Concentric Bends
6:48
5 лет назад
How to Calculate Conduit Fill
14:24
5 лет назад
Programming a VFD from the Keypad
14:51
5 лет назад
Basics of VFD Operation
15:31
5 лет назад
Basics of AC Motor Operation
6:23
5 лет назад
Lutron Vive lighting control
23:43
5 лет назад
Troubleshooting a Motor Starter
10:45
5 лет назад
Комментарии
@Bloodhound_Dogg
@Bloodhound_Dogg 6 дней назад
This is the best explanation that I have seen on the Internet
@AccessToPower
@AccessToPower 5 дней назад
Thank you for your comment! It’s highly appreciated.
@koarivera9151
@koarivera9151 6 дней назад
How did you get 17?
@ifubaraboyerowland8490
@ifubaraboyerowland8490 9 дней назад
I like your video and I want to learn I like your explanations more but the diagrams are not clearly seen the background and the colour of the drawing is not distinct add colours
@Robert-qw7ex
@Robert-qw7ex 14 дней назад
Can you do a video on derating so many people don’t understand it’s of the wire insulation not the device terminal ratings electricians don’t understand you can use the 90deg column when derating
@Robert-qw7ex
@Robert-qw7ex 14 дней назад
Amazing video access to power is golden
@HICDIY
@HICDIY 21 день назад
Great
@RGL642
@RGL642 26 дней назад
Hello, I have wired my 3 phase motor per your video and used same components best to my knoledge, the issue I'm having is when I turn on my 120v brkr it pops. I looked over everything a phew times and can't see what's wrong. Any ideas. Thank you for your time.
@Penguin545
@Penguin545 29 дней назад
Long story short multiply the gapping center to center times the shrinkage of whatever offset angle you are using, so 2 inch spacing with 30° offsets would have you advancing each mark a half inch on every pipe for your starting point. 🤘
@koarivera9151
@koarivera9151 29 дней назад
Excellent tutorial keep up the great Work
@angelagilbert995
@angelagilbert995 Месяц назад
Very well done!😊
@SimataMulenga
@SimataMulenga Месяц назад
Thank you
@burgessbrooks4435
@burgessbrooks4435 Месяц назад
Thanks for the video but let's save some time 1/2 tangent of your degree x gap of pipe. Add or subtract from your 1st mark depending on if it's the shortest or longest your starting with. Also this should work the same for kicks
@mikeyjay917
@mikeyjay917 Месяц назад
Is this the 2nd part of something? Where's the black wire come from why are there 2 reds and 2 greens? Those you've described well,but not the grey thing with 20+ places for wires to go
@mikeyjay917
@mikeyjay917 Месяц назад
Paint the edges of the feet on your stand white to match the rest
@JohnHelsel
@JohnHelsel Месяц назад
great video!n
@svsoleil3255
@svsoleil3255 Месяц назад
I love this channel...great information and really nice/fun guys who know how to relay info...
@rockbottomi
@rockbottomi Месяц назад
so in the angle pull we still had to size up the box to get 12 inches between raceway?
@ray603prospecting2
@ray603prospecting2 Месяц назад
Greate video and explanations. By any chance would you be able to put out a bill of material on all the components you used in this video. I'm looking to wire my garage elevator in this manner. One switch downstairs one upstairs and one on the lift.
@connorchamsarian-soule1633
@connorchamsarian-soule1633 Месяц назад
So I have a question, Why don't u have to account for the cross-section area when u put all the numbers in. Was it because it was already account for in the code book?
@wiliamcorrea9854
@wiliamcorrea9854 Месяц назад
Good job
@MarcusAurelius-88
@MarcusAurelius-88 Месяц назад
What app are you using sir?
@nickmedina3903
@nickmedina3903 2 месяца назад
Should also make sure that your multimeter is rated for the voltage/ amperage you're measuring. If the multimeter isn't rated appropriately it could cause death.
@paulramirez1774
@paulramirez1774 2 месяца назад
More videos please!
@onefixitman
@onefixitman 2 месяца назад
For the purposes of the viewer you should put a piece of blue tape on the motor shaft so we can see the motor reverse directions. Great video.
@seanb2491
@seanb2491 2 месяца назад
By far best explanation
@rowellcanillo7469
@rowellcanillo7469 2 месяца назад
Is table 8 is only applicable in DC system?
@johnhislopjr.7487
@johnhislopjr.7487 2 месяца назад
Ive had to check a lot of these. I would check the overload for tripping first. Then the 480 V fuses and then the motor for grounds. I found that rarely did the control circuit had problems.
@JeanpaulLapointe
@JeanpaulLapointe 2 месяца назад
It's called motor pluging foward to reverse not a problem 21:10 21:10
@95ffd
@95ffd 2 месяца назад
Great Video! What software are you using for your example?
@koarivera9151
@koarivera9151 2 месяца назад
By far one of the best instructors on RU-vid right now coming from a Utah Journeyman
@hetasarvaiya6443
@hetasarvaiya6443 2 месяца назад
Motor control forward start yellow stop off reverse green switch power teacher ji
@trade_design23
@trade_design23 2 месяца назад
The moving photo of the women was distracting, childish and unnecessary. Just talk about the formulas. We don't need or want a show, we want an explanation.
@jameswright7960
@jameswright7960 2 месяца назад
Does anyone know what software is being used for the simulation?
@AccessToPower
@AccessToPower 2 месяца назад
It is called Constructor
@jameswright7960
@jameswright7960 2 месяца назад
@@AccessToPower Thank you! Great videos by the way!
@hetasarvaiya6443
@hetasarvaiya6443 2 месяца назад
Timer motor power start stop off emergency reset teacher ji
@jsmithnevinsky
@jsmithnevinsky 2 месяца назад
ba- LA - kla - va
@mazmaz5136
@mazmaz5136 2 месяца назад
SAME AS CEC CANAD CODE BOOK NICE
@davidhamilton2708
@davidhamilton2708 2 месяца назад
Making it easier s not a problem why don’t you show them how to measure for a concentric bend in the field
@johnsciarrone7245
@johnsciarrone7245 2 месяца назад
Great video, however I have a suggestion. Use a digital protractor on the long side of the pipe , zero it, than after your first bend test the bent end for 30 degrees. Also note the spring back and write it down for the next guy. For example you might have to bend a 33 degree bend for a perfect 30. Thank you for your video.
@FRJ1982
@FRJ1982 3 месяца назад
When you were testing the power button, where dod you have your red meter lead?
@waywardson71
@waywardson71 3 месяца назад
Great information and well taught
@pululunguente
@pululunguente 3 месяца назад
And what about you having 2 sets of conductors with Z method? Please Help!!
@joshleyba3854
@joshleyba3854 3 месяца назад
I have 4 mixer motors at a WWTF. I have had to turn the yellow amp adjustment from 8 to 14 amps to keep them running with out tripping. 1 of of them however now runs for 1-3 mins then trips everytime. Pulled and megged motor. It is good. Voltage is good and consistent with other mixer motors. I have not seen Amps above 7 on anyof the motors including the one tripping. Any suggestions? Going in circles with Evoqua. Plant is 1 year old. All ran good first 6 months then developed issues after that.
@fuzzfacelogic789
@fuzzfacelogic789 3 месяца назад
You're using 10amps for VFD and motor control yet say that 10amp relay not to be used with anything requiring a load? 10amp is the common rating for general residential use, lights and power points, here in Australia.
@AccessToPower
@AccessToPower 3 месяца назад
The 10 amp relay is being used to on the control circuit of the VFD… not the motor circuit. The current on the control for a start signal is measured in milliamps.
@fuzzfacelogic789
@fuzzfacelogic789 3 месяца назад
@@AccessToPower Please excuse my ignorance.
@AccessToPower
@AccessToPower 3 месяца назад
@@fuzzfacelogic789 no worries. Thank you for watching and commenting on these videos. We created them to be helpful. Hopefully they accomplish that goal.
@diegojones2481
@diegojones2481 3 месяца назад
This guy explains everything so well
@tnr6898
@tnr6898 3 месяца назад
You still need some electrical knowledge to understand this video. I know almost nothing and get lost after he adds the bridges. More detail on components is needed.
@hhr1985
@hhr1985 3 месяца назад
I always teach to only swap A & C phase to reverse the phase rotation. This prevents accidentally burning stuff up in the rare time one may have to deal with the high leg on a 120/240 3 phase feed. (Code here is the high leg must be on B Phase)
@AccessToPower
@AccessToPower 3 месяца назад
That is a good idea. Especially if the control voltage is 240 volt delta. But it is a good practice to teach newbies as it eliminates possibly making a mistake when the voltage, or high leg information is not understood or known. And yes, High Leg is most often on B Phase in the field... but there are some utilities that provide the high leg on C phase and it must be switched after the MSB to B phase on all Panelboards, and MCC's. This too can be a bit confusing and cause people to make mistakes. Thanks for your comments and sharing your best practices with the community.
@WestBuilt323
@WestBuilt323 3 месяца назад
4th year apprentice here , thanks for the smooth video 👌
@AccessToPower
@AccessToPower 3 месяца назад
Glad the video was helpful, and thanks for commenting.
@Manchessollte421
@Manchessollte421 3 месяца назад
dude this is amazing, thank you so much. having an ACTUAL MOTOR is going next freaking level. thank you.
@AccessToPower
@AccessToPower 3 месяца назад
Thank you. I appreciate the comment.
@123verne
@123verne 3 месяца назад
Why does the neutral have to go through the overload relay and not just straight to the coil (A2)?
@AccessToPower
@AccessToPower 3 месяца назад
If the neutral went straight to the coil then the motor starter would never trip due to an overload
@123verne
@123verne 3 месяца назад
Ok thanks
@jesuspaz7446
@jesuspaz7446 3 месяца назад
AWSOME VIDEO
@AccessToPower
@AccessToPower 3 месяца назад
Thank you for the comment! I appreciate your feedback.