Great Video, I had to purchase a new deep well pump and it wouldn't prime. so I had to pull 45 feet of 1 1/4" PVC pipe out of the well and replace the leather seals. Pump works great now.
Mali ang bata mo sobrang hinigpitan ung kanan kaya naputol ,tskk tapos ung customer ang kawawa bibili ng bago .hayss dapat hnd mo iniwan boss hnd nakikinig
Kawawa ako dyan sa bata ko na yan hehe. Imbis na makatipid sa pagrepair ng sariling poso namin e, napagastos pa nga at napabili tuloy ako ng new deep well adapter ng wala sa oras.
Napaka hirap nga tlga mag baon nyan lalo na g.i ang gamit na pipe nakaka kaba haha dahil kapag mabitawan naku patay 🤣kaya ung samin PVC lng pinakabit ko para Incase na magpalit ng leather cup kayang kaya ko na .nice one sir .
Sir yung pong deep well namin di ko mapalitan sapatilya. Hindi mahugot yung mga tubo parang nakasabit sa ilalim.ano kaya maganda gawin? Kada papaandarin kailangan mo pa buhusan ng tubig
You are correct they do fail. What i did was (can't remember if it can be seen on the video though), i just tried stretching the stainless spring of the foot valve by a couple of millimeters to tighten its fit when it closes. So far, it is still working perfectly.
I'm not sure po about sa naputol o naiwan na ejector sa ilalim o dulo ng pipe. Pero wala po ako naiisip na iba way para makuha pa yun pataas. The only thing left to try ay tama po kayo maglagay po ng bago at make sure secured po ang fit. Check din po ang straw para sa mga corroded na point kung saan nagsisimula yung mga butas hanggang maputol ang tubo. Then, itulak na lang pababa.
Sa mga hardware sir para makita mo mismo kung legit na U.S. quality. Mas mura sa mga online gaya ng Lazada at Shoppee pero hindi ko pa nasubukan kung US made talaga.
Ok Good showing of Leather replacement but no need to really stretch them normally. Only one or three wraps of Teflon tape is needed to tighten and seal the threads. Always replace the foot valve when you have to replace the leathers or else you will be pulling the jet again. The jet doesn't have to be joint breaking tight and you can crack PVC adapters if overtightened. Also try not to use pvc couplings when reinstalling the jet pipe they are too weak when pulling and can break. You usually want to just pull jet pipe out and put in a tree or over a roof to not break and just reinstall. If the pipe is really old its better to just replace and use the factory bell ends with new crown adapters.
Got a question. I got this packer well set up. And jet pump works fine pulls water and fills my tank. But pressure switch won't shut off pump. Tried adjusting no change. Could this mean I need to pull jet and inspect and reseal ? It sounds like it's not tight, just not sure whether at the top or bottom? How to get pressure switch on pump to start working ??
@@danhillsablas9121 hindi po ako sure if pwede po i-fabricate sa rubber. Tinanong ko po yung professional na gumawa sa amin dati, meron daw po nabibili na rubber cup pero hindi daw po tumatagal kagaya ng leather material.
Bos sa tabi Ng Bahay ko may lumang Puso. Katulad Ng set up Ng inayos Nyo. Sinubukan Kong e konek sa shallow pump. Humihigop sya pero napakahina Ng tubig. Sinubukan Kung hugutin Ang tobo kaso Ang tigas. Dahil siguro sa leather cup?
Baka hirap yung shallow pump sir kaya mahina, baka need ay deepwell pump. Gaano ba sir kalalim ang casing na tubo sir? At yung straw pipe gaano kahaba? Na try nyo ba sukatin ang level ng tubig?