Everything you wanted to know about Variable Refrigerant Flow systems, from engineering, estimating and field installation techniques. You'll find the latest information on code and technical requirements.
VRF Compressor Types
12:40
2 года назад
ZoomLock or RLS vs Brazed Fittings
11:37
3 года назад
VRF Piping Design Software
9:29
3 года назад
COP and KW per Ton
6:21
5 лет назад
VRF Rooftop Packaged Units
6:59
6 лет назад
ZoomLock Klauke 19 kn Tool Review
17:41
6 лет назад
How to Read a Metric Scale
11:05
6 лет назад
VRF System Control Wiring
6:48
6 лет назад
HVAC VRF System Heat Recovery
7:33
6 лет назад
Комментарии
@mohamedragab4828
@mohamedragab4828 Месяц назад
Very helpful info thank you . need to ask why did not u use the floor area of the building . its need to be used if its on a unconditioned space
@andyoohhh2061
@andyoohhh2061 Месяц назад
I was trying to figure out how to determine the number of air changes you need for a specific room. Is it based all on code? Maybe Square footage? Where can you find that information?
@neelakantarao8103
@neelakantarao8103 Месяц назад
Hello Sir, you explained back calculations only. First you declared 4 Air changes per hour and calculated CFM. Again same CFM value used for Air changes per hour calculations. Can you explain, how to calculate CFM without knowing the Air Changes per hour value?
@ayadayad4299
@ayadayad4299 Месяц назад
Excellent.. Plz we need video abijt Electrical Destrbution board & cable for outdoor unite.. With simply exampl.. Thx
@krishna-mg9zt
@krishna-mg9zt 3 месяца назад
how to know Eth & Lth?
@stefanosega7280
@stefanosega7280 4 месяца назад
You are confusing energy with power. BTU is energy (heat). Watt is power (heat/time). So, at minute 3.00, 1 watt should equal 3.41 BTU PER HOUR.
@phinehasfenne
@phinehasfenne 7 месяцев назад
Chiller Killer!
@NeGBusa
@NeGBusa 9 месяцев назад
Sssoo simple to understand 🤙🏻
@RMalai
@RMalai 10 месяцев назад
Loud and Hear. We all heard it!! Good instructor. This is how I also teach.
@sajju423
@sajju423 10 месяцев назад
T for?
@dtg8672
@dtg8672 11 месяцев назад
How are loads calculated if the room is centrally located in the building with no windows? Do you still do the solar load for the building envelope?
@grth3929
@grth3929 11 месяцев назад
Ive looked at a dozen references for the proper air changes per hour for different areas and every single one is different lol. Either super low or super high.
@santosnajera8358
@santosnajera8358 11 месяцев назад
Nice video I have a question, I’m studying drafting , I’m just started learning about metric scale but what I don’t get how to convert example 1:80 scale into example (m, mm, or km) can you help me?
@lijupulimoottil1780
@lijupulimoottil1780 Год назад
goog one, thx.
@user-ff1ki7np2s
@user-ff1ki7np2s Год назад
Hi, great video explanation. I need to know, what's in metrics formula? and what does it mean when the value of cooling coil total heat transfer is positive and negative?
@Lilsoso401
@Lilsoso401 Год назад
wow!!! the clearest scale ruler explanation I've found. So good. Very thankful
@user-pe8lm2qk8u
@user-pe8lm2qk8u Год назад
Im korean your video is good!
@VRFWizard
@VRFWizard Год назад
Thank you
@solomongoderdzishvili7273
@solomongoderdzishvili7273 Год назад
Sorry what is different between minimum outdoir air change and minimum total air change
@user-iv5ub4hv4w
@user-iv5ub4hv4w Год назад
Why did you assume 4
@otiahaill
@otiahaill 9 месяцев назад
I is an assumption based on the requirements that the owners of the room might have requested
@dailylifeexperiences2797
@dailylifeexperiences2797 Год назад
What is the recommended ACH kitchen and living room ?
@VRFWizard
@VRFWizard Год назад
Ventilation requirements can be found in ASHRAE 62.1 for Commercial Buildings and 62.2 for Residential Buildings. The use of residential bathroom and kitchen exhaust fans assist with any pollutants generated in those spaces, so it's important to make sure that those fans are operating when those spaces are being used.
@spruce_goose5169
@spruce_goose5169 Год назад
I live in the land of leaky houses where air leakage is a MAJOR source of heat loss in winter. Do you have any actual evidence that the air infiltration is a small sum of the load in cooling mode?
@VRFWizard
@VRFWizard Год назад
We mostly handle large commercial properties. For an older home, infiltration or exfiltartion could be much greater, depending on the quality of construction, window and door types, etc.
@techdan7098
@techdan7098 Год назад
Hello, I've been finding your video on calculating cooling loads extremely informative. I have some specific queries about the Solar Cooling Load (SCL) component of the calculation. I understand that SCL is influenced by factors such as the orientation of the glass, the month, and the time of day, and it's a dimensionless ratio typically ranging from 0 to 1. However, in your equation, you've utilized a value of 250 for the SCL. Could you please explain how this number was derived and why it's used instead of a value between 0 and 1? Is this value a constant, or does it change based on certain variables? If it does vary, how would I go about calculating or finding the appropriate value for my own home's specific conditions? Your clarification on these matters would be greatly appreciated. Thank you for your time and assistance in advance!
@steveowen5143
@steveowen5143 Год назад
Very helpful info thank you. This is helpful for basic sizing of cooling coils.
@VRFWizard
@VRFWizard Год назад
You're Welcome. Thanks for watching.
@dpool7416
@dpool7416 Год назад
How the hell do you calculate SCL though, that was a very poor explanation of it.
@Murari1960
@Murari1960 Год назад
Excellent.informative for fresh graduates.
@annexkidula9184
@annexkidula9184 Год назад
Nashukuru
@ronmaren4135
@ronmaren4135 Год назад
I thought the playback speed was on 0.5
@VRFWizard
@VRFWizard Год назад
Everyone listens at different speeds. The good thing is that the user can always adjust the speed to fit their own preference.
@ronmaren4135
@ronmaren4135 Год назад
@@VRFWizard thanks for the video mate I am just being silly
@prashanthc8135
@prashanthc8135 Год назад
This calculation is applicable for the confined space such as vessel, tanks ?
@VRFWizard
@VRFWizard Год назад
Its good for any enclosure as long as you can calculate the volume.
@stephaniebaldwin4762
@stephaniebaldwin4762 Год назад
Thank you sooo much for this. I've been searching online to understand this formula. Because I am a visual learner I have not understood it until I saw you demonstrate it. 😊😊
@VRFWizard
@VRFWizard Год назад
You're Welcome
@vigneshmurugesan7007
@vigneshmurugesan7007 Год назад
Good explanation
@VRFWizard
@VRFWizard Год назад
Thank you
@charansingrajput5248
@charansingrajput5248 Год назад
Exactly>><<
@saqibazad2237
@saqibazad2237 Год назад
excellent
@VRFWizard
@VRFWizard Год назад
Thank you
@Pujari917
@Pujari917 Год назад
👍
@VRFWizard
@VRFWizard Год назад
Thanks
@VRFWizard
@VRFWizard Год назад
Thanks
@AlexMurilloh23
@AlexMurilloh23 Год назад
I like how well these comments aged in as little as 1 year. Seems like they were afraid of their job security.
@VRFWizard
@VRFWizard Год назад
You're right, as with any new technology there are those that are early adopters, and those who stick to the security of doing things as they have always done them before.
@jessehollenbeck4607
@jessehollenbeck4607 Год назад
Very helpful. Thank you.
@VRFWizard
@VRFWizard Год назад
You're Welcome
@palmabeatriksan7600
@palmabeatriksan7600 Год назад
What are the book recommendations that you often use to learn VRF
@VRFWizard
@VRFWizard Год назад
ASHRAE is the industry leader and they have a chapter in their handbook on VRF that provides a good explanation.
@AlyElhennawy
@AlyElhennawy Год назад
That's great but I have a question, that 108 CFM that you got from your results, is the CFM that supplied for the room or that to be exahuasted outside the room as an return?
@VRFWizard
@VRFWizard Год назад
The 108 CFM is the amount of air that needs to be Exhausted from the space or Recirculated (Return Air) through filters in situations like cleanrooms. Hospitals have many rooms that require a certain amount of ventilation air indicated in Air Changes, and also a minimum amount of air to be recirculated indicated in ACH. The air change calculation is just an indication of how much air is to be replaced within the space, which can either be exhausted or recirculated out of the space and back again through filters or some other process, depending on the application.
@sjefoekel6058
@sjefoekel6058 Год назад
Can you pressfit a txv in reachin cooler? LMAO😁😁, Fire watch? Que? All those times you encounter different pipe sizes, you cant press them eighter! Besides i will bet i am faster with brazing than the zoomleak, with the cutting and fitting checking marking and whatnot.
@VRFWizard
@VRFWizard Год назад
There are advantages and disadvantages to both methods. There are times when the use of a flame is at a disadvantages, like wise there are times when pressfit fittings are not the best choice as you point out.
@salemalzofiri2404
@salemalzofiri2404 Год назад
Do we need to consider the roof as well?
@VRFWizard
@VRFWizard Год назад
Yes of course. Anything that effects the heat gain or heat loss to the space, including interior spaces that are unconditioned and share a wall with the conditioned space.
@erichorton1440
@erichorton1440 Год назад
Very great detail. The charts made it clear and the formulas.
@VRFWizard
@VRFWizard Год назад
Glad it was helpful!
@ekie85
@ekie85 Год назад
How do I change these units ?
@VRFWizard
@VRFWizard Год назад
What do you currently have, and what do you want to change too?
@ekie85
@ekie85 Год назад
@@VRFWizard Haier AUH4860ZGDA GE inverter
@VRFWizard
@VRFWizard Год назад
@@ekie85 If you want to change to a Heat Recovery System, you'll need to have the system redesigned as you'll need the Selector Boxes installed between the Outdoor and Indoor Units.
@shahriarraeisidehkordi4957
@shahriarraeisidehkordi4957 Год назад
thank u so much so so much
@VRFWizard
@VRFWizard Год назад
Your Welcome
@gisound9644
@gisound9644 Год назад
Excellent presentation.
@VRFWizard
@VRFWizard Год назад
Thank you
@rutherford5247
@rutherford5247 Год назад
I dont get it, I thought for example the given is 4cm then to make it to 1:50 scale you will just multiply it by .50, So its 4x.50 = 2 meters. Am I right?
@VRFWizard
@VRFWizard Год назад
Yes, 4 cm equals 2 meters when using a 1:50 scale
@rutherford5247
@rutherford5247 Год назад
10:08 what if the given is 200x64 What will be its result in 1:50 scale?
@VRFWizard
@VRFWizard Год назад
Noted. 100 CM Ductwork would equal 2 CM on the scale for a 1:50 (100 x 1 / 50 = 2)
@rutherford5247
@rutherford5247 Год назад
@@VRFWizard oh ok thank you I kinda get it now
@vimalravindren399
@vimalravindren399 Год назад
How to find the air change rate,does it have any instrument?
@VRFWizard
@VRFWizard Год назад
You can use an anemometer to measure the CFM coming out of your supply grille, then multiply by 60 (60 minutes in an hour) and then divide by the Total Cubic Feet of the Room.
@ironguard4048
@ironguard4048 2 года назад
What about second floors? How does that factor in? Would I just measure temperature gain through the floor?
@VRFWizard
@VRFWizard 2 года назад
If the floor above or below is air conditioned then there is no load. If you have a floor above or below that is not conditioned, like a garage, then you would do the same calculation with the heat gain and loss through the floor.
@khalidelpendery8830
@khalidelpendery8830 2 года назад
Thanx
@VRFWizard
@VRFWizard Год назад
Welcome
@cancersilentkiller
@cancersilentkiller 2 года назад
Thanks 🤩
@VRFWizard
@VRFWizard 2 года назад
Your Welcome
@gosula.amaralingeswararao8698
@gosula.amaralingeswararao8698 2 года назад
Good information ji sir
@VRFWizard
@VRFWizard 2 года назад
Thank you