Know all about Instrumentation and Control Engg fundamentals, latest technologies, Selection & Installation techniques, Interview Questions, case studies etc.
AI in Process Automation
10:13
2 года назад
AI in Process Automation (in Hindi )
9:33
2 года назад
How to Select Control Valve?
12:17
2 года назад
Why 4 - 20 mA? ( in Hindi )
9:25
2 года назад
Why 4 - 20 mA is used  ?
9:27
2 года назад
Load Cell Sensor | Weighing Techniques
13:14
2 года назад
Комментарии
@mumtazalam4882
@mumtazalam4882 12 дней назад
Good
@bhaveshnakum6733
@bhaveshnakum6733 15 дней назад
Very informative video Sir what is different between horn antenna and Dome (process seal) antenna in Radar transmitter
@ramirochoque3400
@ramirochoque3400 20 дней назад
Thank you for sharing this topic of the OPC protocol in a clear and concise way, I understood it more by watching your video, since in other videos or blogs they explain a lot but are not clear, congratulations
@POWER_OF_TECHNOLOGY643
@POWER_OF_TECHNOLOGY643 Месяц назад
Practically can you show this process sir
@dineshdiwani
@dineshdiwani Месяц назад
@@POWER_OF_TECHNOLOGY643 you too can drive car and feel yourself like a PID controller
@RAKESH-hm1mv
@RAKESH-hm1mv Месяц назад
Good explained sir
@gramanathapai8477
@gramanathapai8477 Месяц назад
Very nice Sir. Thank you
@SauravKumar-ng8cp
@SauravKumar-ng8cp Месяц назад
Very good explanation
@srikanth0282
@srikanth0282 Месяц назад
Sir, how to avoid continuous change in level measurement, when we measure reservoir (dam) level which has continuous tides.
@dineshdiwani
@dineshdiwani Месяц назад
@@srikanth0282 Provide damping in transmitter to damo the oscillation. These changes must be periodic in nature. It is in time, mostly in seconds. Try out and tell me.
@srikanth0282
@srikanth0282 Месяц назад
Sir, what is the maximum distance for 4 to 20mA signal?
@dineshdiwani
@dineshdiwani Месяц назад
@@srikanth0282 Practically I never faced distance issue. Theoritically it is infinte as current remains same in series formed by power source, AI I/O channel and transmitter.
@satishkumarkashyap8028
@satishkumarkashyap8028 Месяц назад
एक्सपीरियंसड सर 👌
@rameshmulumoodi1549
@rameshmulumoodi1549 Месяц назад
Feed forward control systems, which are in existence since last 50 years are based on prediction or foreseeing the possible error that could creep in. The best example is 3-Element Boiler Drum Level Control system. In this case, steam flow, feed water flow and drum level are measured and two PID controllers are used. During load changes, steam flow varies which with certain delay impacts drum level. The steam flow is used as feed forward correction and feed water control valve is manipulated to ensure drum level remains undisturbed. In Paper making process where multiple parameters are to be measured and used to control paper quality parameters, mathematical models are built (in DCS) which ensure optimized production. These models also use historical data to update themselves. A control valve (with it's position feed back to DCS) which over a period of time can get sluggish can also be compensated for it's slow performance. All that I discussed here were available in ABB DCS which works in conjunction with ABB 1190 Accuray Smart Platform. I was trained on these systems in 1992 in Columbus, Ohio, USA. In 90s we also learnt fuzzy logic. Even the so called IoT was available in 90s but with a different name.
@dineshdiwani
@dineshdiwani Месяц назад
@@rameshmulumoodi1549 does it learn from past 6 months performance? From What was the behaviour ?AI models perform better and better from the past behaviour. The 3 element control system you mentioned. It works on present status of the process, it predicts all the disturbance presently available and act accordingly. But AI model has all the learning of past behaviour. So it knows what going to happen, and to act accordingly. Hope you get what I want to say.
@TechTutorial20
@TechTutorial20 Месяц назад
Thanks for a nice informative video...
@masumahmed7978
@masumahmed7978 Месяц назад
just wow
@masumahmed7978
@masumahmed7978 Месяц назад
nice boss
@imranhayat198
@imranhayat198 Месяц назад
Degital analog difrans me noladge batavo
@rizwanzafar9809
@rizwanzafar9809 2 месяца назад
AMAZING EXPLANATION SIR. VERY INFORMATIVE. THANKS SIR.
@learning9503
@learning9503 2 месяца назад
Thanks for Hindi
@learning9503
@learning9503 2 месяца назад
Please Hindi
@dineshdiwani
@dineshdiwani 2 месяца назад
@@learning9503 it is there in hindi too. I post every video in Hindi and English.
@vikramkekan7499
@vikramkekan7499 2 месяца назад
Khop chan👍
@learning9503
@learning9503 2 месяца назад
Beautiful
@swastikdutta2267
@swastikdutta2267 2 месяца назад
Sir best
@mohammadmobin6971
@mohammadmobin6971 2 месяца назад
Hello Sir, gsdml v2.3 siemens sinamic g120 20130109.xml download How can I download this gsd file I searched in internet but not found. Install other upgraded gsd file but this project is not opening Kindly suggest
@ssm9419
@ssm9419 2 месяца назад
Dear Sir your explanation is purely professional way but please, if it is in English, it will reach all over India
@dineshdiwani
@dineshdiwani 2 месяца назад
@@ssm9419 I make videos in Hindi and English plus all subtitles available for most spoken languages. Please browse my channel for english videos
@sunilchavan7447
@sunilchavan7447 2 месяца назад
Sir can we download the virtual PLC in Laptop. if yes can you please share any link.
@dineshdiwani
@dineshdiwani 2 месяца назад
@@sunilchavan7447 yes it is downloadabale but It is in early development stage and and released by Siemens only and commercially available.
@sunilchavan7447
@sunilchavan7447 2 месяца назад
@@dineshdiwani Thank You Sir...Also i tried to join the channel but there is issue with payment fail.
@Craigtucker99Tucker-zx1yd
@Craigtucker99Tucker-zx1yd 2 месяца назад
Thank you sir please make more
@dineshdiwani
@dineshdiwani 2 месяца назад
@@Craigtucker99Tucker-zx1yd sure.. keep sharing
@jogendrasingh9978
@jogendrasingh9978 3 месяца назад
Thanks sir
@dineshdiwani
@dineshdiwani 3 месяца назад
@@jogendrasingh9978 🙏
@SaritaDevi-hn3wo
@SaritaDevi-hn3wo 3 месяца назад
Excellent sir
@dineshdiwani
@dineshdiwani 3 месяца назад
@@SaritaDevi-hn3wo thank you, do share among your colleagues and friends
@anaglokesh7511
@anaglokesh7511 3 месяца назад
Sir , why charging circuit is available in VFD schematic circuit?
@dineshdiwani
@dineshdiwani 3 месяца назад
@@anaglokesh7511 its rectifier with capacitor not charging circuit. As inverter has to deliver frequency from min to max so it need near pure DC from rectifier.
@sachingupta6883
@sachingupta6883 3 месяца назад
Sir Your videos are quite good regarding instrumentation please continue the same.
@dineshdiwani
@dineshdiwani 3 месяца назад
@@sachingupta6883 thank you sure
@sachingupta6883
@sachingupta6883 3 месяца назад
@@dineshdiwani Please make a video on modbus communication
@bbarot124
@bbarot124 3 месяца назад
Sir please tell me how to check whether lorry weighbridge is manipulated or not.
@dineshdiwani
@dineshdiwani 3 месяца назад
@@bbarot124 keep a vehicle in your control whose weight you know, for example you car or tractor or any other vehicle under your control. And keep weighing that vehicle frequently I.e. daily, weekly monthly. This way you basically checking it's calibration against standard weight. Any deviation may indicate some kind of manipulation.
@vinodkumarprajapati5182
@vinodkumarprajapati5182 3 месяца назад
बहुत सुन्दर 👍
@amitkumar-sh2lk
@amitkumar-sh2lk 3 месяца назад
sir aap kaun si psu me hai?
@dineshdiwani
@dineshdiwani 3 месяца назад
@@amitkumar-sh2lk private company
@shivnathbhosale380
@shivnathbhosale380 3 месяца назад
Load cell ya controller me Pani gaya to kya problem Aati hae
@dineshdiwani
@dineshdiwani 3 месяца назад
Pahle to pani jayega nhi kyonki load hermatically sealed hota hai.... Agar gya to dc supply short ho jayega load cell controller ki .. load me pani se damage hona ka kuch nhi hota
@vinodkumarprajapati5182
@vinodkumarprajapati5182 3 месяца назад
Good
@talibhusainsaqlaini4396
@talibhusainsaqlaini4396 3 месяца назад
Very nice explained
@publikjuli
@publikjuli 4 месяца назад
Why does he speaks in English for a sentence then switch back to something else?!
@hardikparmar5074
@hardikparmar5074 4 месяца назад
Nice video sir but i have required control valve trouble shooting problems
@kamleshsawant4
@kamleshsawant4 4 месяца назад
Very nice sir. Thank you!
@palanisamy7137
@palanisamy7137 4 месяца назад
What will Happen PIF If PV fails ?
@dineshdiwani
@dineshdiwani 4 месяца назад
You can put if then condition to bring control in manual mode or whatever fail safe condition you opt
@palanisamy7137
@palanisamy7137 4 месяца назад
@@dineshdiwani sorry my question is spell mistake.what will happen PID and Final control element If PV fails. Whether PID Will go IMAN mode and AO will hold the Last good Value or AO will go to fail safe position?
@dineshdiwani
@dineshdiwani 4 месяца назад
@@palanisamy7137 you can hold last value AI (PV) or you can program PID module to be fail safe go to max or min output on account of PV fails. Holding last value of PV is good idea that way you process will bot disturb.
@ranjit1576
@ranjit1576 4 месяца назад
Thank you sir
@muhammadumairkhan86
@muhammadumairkhan86 5 месяцев назад
Make video on this topic
@muhammadumairkhan86
@muhammadumairkhan86 5 месяцев назад
Comparison between Canbus and profibus
@dineshdiwani
@dineshdiwani 5 месяцев назад
Ya sure
@RajeshT-x7j
@RajeshT-x7j 5 месяцев назад
dear sir can you provide vplc software for trail purpose
@dineshdiwani
@dineshdiwani 5 месяцев назад
Only Siemens has come up with such idea.. the thing is yet to be commercialized
@thippesh_trpani6584
@thippesh_trpani6584 5 месяцев назад
Very good information about the conepts... Can u make how profibus devices are programmed in plc
@dineshdiwani
@dineshdiwani 5 месяцев назад
I will
@thippesh_trpani6584
@thippesh_trpani6584 5 месяцев назад
Tq u..
@ashutosh_travel_videos
@ashutosh_travel_videos 5 месяцев назад
Sir can we know the functioning of CJC circuit?
@dineshdiwani
@dineshdiwani 5 месяцев назад
I have described it all in video
@wrovesgears
@wrovesgears 5 месяцев назад
GREAT SIR
@sksafik5872
@sksafik5872 5 месяцев назад
GOOD
@SanJay-wp1tg
@SanJay-wp1tg 5 месяцев назад
thanks for the information pls share general thumb rule to calcualte the memory requirement of Allem Bradley plc for a customised application
@dineshdiwani
@dineshdiwani 5 месяцев назад
One byte for one programming instruction.. also add future requirement Memory is decided by length of program of no of drives, PID, AI etc. Based on calculation, memory can freezed
@SanJay-wp1tg
@SanJay-wp1tg 5 месяцев назад
@@dineshdiwani but while developing a application i cannot fore see actual number of instructions that will be required. how to add DIDO and AIO in calculations
@dineshdiwani
@dineshdiwani 5 месяцев назад
@@SanJay-wp1tg program length is decided at plant design stage, based on number of inputs outputs and type of control scheme, control loops etc
@riturajajay7029
@riturajajay7029 5 месяцев назад
❤❤❤
@waheedahmad155
@waheedahmad155 6 месяцев назад
Sir kia hum pid comand weighing batching cotrole k lie use kr skty han?
@dineshdiwani
@dineshdiwani 6 месяцев назад