I show how to calibrate the KSGER soldering station for different tips.
I did a comprehensive review of the KSGER which you can find here: • 🔴 #504 KSGER T12 OLED ...
HW 2.1S Oddity: • 🔴 #574 KSGER T12 Hardw...
Calibration of tips on the KSGER is actually pretty easy, you just need a suitable tip tester such as the FG-100 to see the actual temperature then you can set the actual temperature on the KSGER.
Buy the KSGER Soldering Station: defs.link/?u=5c112e
Subscribe and click the Bell Icon to get notifications so you don't miss out on my future videos.
Thumbs Up and Share the video with your friends so they get to see the videos too!
Affiliate links: (Bookmark and buy using them)
Banggood: defs.link/?u=5d46ae
Amazon Store: www.amazon.com/shop/thedefpom...
Subscribe: defs.link/?u=ffa106
Test Equipment Repair Videos: • Test Equipment Repair,...
Electronics & Repair Videos: • Electronics & Repairs
Review & Teardown Videos: • Teardown & Reviews
Mailbag / Postbag Videos: • More Mailbag Videos
Electronics Project Videos: • Electronics Projects
Apple Repair Videos: • Apple Repairs
CB & HAM Radio Videos: • CB & HAM Radio Repair ...
TheDefpom Merchandise: teespring.com/stores/TheDefpom
Donate so I can make more videos for you, see links below, cheers:
Become a Patreon! defs.link/?u=fcb3a1
PayPal Donations: defs.link/?u=b099ee
My 3D printed replacement test equipment parts on Thingiverse: defs.link/?u=0347b1
My website (well, one of them): www.TheDefpom.com
My Twitter: / thedefpom
I upload new videos at the same time each morning (NZ Time) at least 3 times a week, on Monday, Wednesday and Friday at a minimum, if possible I will also do a Live Stream on a Sunday morning, so watch out for those too.
#TheDefpom
#IFixStuff
#Electronics
#Defpom
#TestEquipment
#Review
#KSGER
==========================================
Some Of My Electronics Tools (video and purchase links)
==========================================
Boonton
------
4220.
8210: defs.link/?u=e1eddc
Fluke
------
8842A:
45: defs.link/?u=eac51d
343A: defs.link/?u=13c93d
5200A: defs.link/?u=a43c99
540B: defs.link/?u=0c6bd9
893A.
A90.
HP/Agilent/Keysight
------
4261A: defs.link/?u=07ed95
5005A.
5342A 18GHz: defs.link/?u=5f7513
6181B: defs.link/?u=b12aef
8012B: defs.link/?u=ca5764
8648B: defs.link/?u=da52a3
8901B: defs.link/?u=535835
DSOX1102G: defs.link/?u=a68d39 defs.link/?u=12d498
E3646A: defs.link/?u=128f4a
Marconi
------
2022D.
2955.
TF2103: defs.link/?u=61baaa
Rohde & Schwarz
------
SMY: defs.link/?u=93514b
CMU200: defs.link/?u=8ccd72
Polarad SPN: defs.link/?u=2ead82
Siglent
------
SDM3065X: defs.link/?u=1ed0fe defs.link/?u=12d498
SDS2102 (hacked to 340MHz): defs.link/?u=1ed0fe defs.link/?u=12d498
SPL-1008.
SDP1168X: defs.link/?u=1ed0fe defs.link/?u=12d498
SDL1020X-E: defs.link/?u=a0eccb
Other Equipment
------
KSGER T12 Soldering Iron: defs.link/?u=620ace defs.link/?u=5c112e
Quick 861DW: defs.link/?u=138c0f defs.link/?u=a3fc81
S-993A: defs.link/?u=079677 defs.link/?u=e855a0
EEVBlog BM235: defs.link/?u=12d498
YR1030 Battery ESR: defs.link/?u=c56527
Heathkit IT-12 Signal Tracer.
Racal Dana 1992: defs.link/?u=8eeeba
Bird 43: defs.link/?u=4b18f7
Sinadder 3: defs.link/?u=2bf1dd
Audio Control SA-3050A RTA: defs.link/?u=a04df2
Korad KA3305D: defs.link/?u=69090a
PDVS2mini: defs.link/?u=869ba4
Valhalla 2703: defs.link/?u=06bcfc
Feeltech FY6800: defs.link/?u=8b98cd defs.link/?u=34d101
Eakins Microscope: defs.link/?u=b0278b defs.link/?u=262327
Mustool G600: defs.link/?u=b8bc26 defs.link/?u=33f0aa
Handheld Equipment
------
Uni-T UT210E: defs.link/?u=391ce3 defs.link/?u=ea4edc
DER DE-5000: defs.link/?u=0d9160 defs.link/?u=12d498
MK-328: defs.link/?u=0d9160 defs.link/?u=739ee7
MESR-100: defs.link/?u=0d9160 defs.link/?u=009419
ESR Meter: defs.link/?u=0d9160
HOPI: defs.link/?u=7fab55
PeakMeter PM6252: defs.link/?u=59ef66
HS1010: defs.link/?u=10c699
Thermal Camera: defs.link/?u=280cca defs.link/?u=4a2256

Наука

Опубликовано:

 

6 май 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 51   
@nghtrdr
@nghtrdr 5 лет назад
Just thought I would add for anyone new to calibrating solder tips. Hakko recommends to let the fumes (smoke) dissipate after adding solder to the tip before taking a reading. This is to make sure that the flux burns off and doesnt interfere with the reading. I can say for certain that for me this made for a very accurate reading with the fg-100. My ksger station is +-2 deg at rest, where before doing this it was +- 8 deg. Great vid btw
@GulczTech
@GulczTech 5 месяцев назад
Thanks man. Greeting from Poland.
@terrybaileysr.3714
@terrybaileysr.3714 Год назад
I don’t have that fancy temperature meter. Can I use the temperature probe on my multimeter?
@dancoz5477
@dancoz5477 8 месяцев назад
Hi. Sir. Your video is great. The filming is professional and all. The sound is 10/10. I am not an anglophone. Hence, I would like to tell you that following you is hard for two reasons. First you speak fast and that can be corrected. Then, unfortunately you have a british accent and that is not your fault, perfection his hard to achieve 🤩. Moreover, it can not be treated or changed 😪. Hope I have not offended you but just trying to strive upwards. Keep up the the good work. Slava Ukrn. (I just purchased one)
@kenjunge2768
@kenjunge2768 5 лет назад
Thank you. Did not know that. Now to calibrate 12 tips :-)
@davidv1289
@davidv1289 5 лет назад
Really informative video! Now I know what that zero means. I'm going to have to get a themometer and calibrate all my tips.
@randyking3691
@randyking3691 5 лет назад
Thank you . I needed that.
@DarthMaul41
@DarthMaul41 3 года назад
Hi! My KSGER (version 2.1S) displays a wrong tip temperature when completely cold. At 24 C in the room measured by the handle's NTC, the measured tip temperature is 57 C. That's the same for all my 16 tips I have... I suspect there's something going wrong on the board, any idea?
@juggalizzle75
@juggalizzle75 4 года назад
Fyi my unit came with a tip that had a hard short. It caused the unit to reboot several times then go dark for good. I figured it out on the replacement unit when it started rebooting. Apparently qc isn't very good. A shorted tip? And no short protection? Also, the first handle was way to sensitive and would wake up the unit by breathing in it. The 2nd didn't wake the unit up at all.
@pr0xZen
@pr0xZen 3 года назад
All my 15'ish tips have a negative 77°C offset versus the reading, +/- 3-5 degrees. Is there some way to calibrate or adjust the station's own baseline temp by that much? Clearly it has to be the station's baseline that is off here (V2.1S) - no way all these tips including several original Hakko's, would all be roughly 77°C off.
@junejeesipin7555
@junejeesipin7555 3 года назад
My tip is burning up even i calibrate it... and also even no tips still working... what is the problem?.. i try other psu its the same... can you help me? Thanks
@rollyavecilla
@rollyavecilla 5 лет назад
Have you encountered this unit that keeps rebooting? If you have, we're you able to fix it?
@juggalizzle75
@juggalizzle75 4 года назад
My unit came with a tip with a short. If you let it reboot too many times under power like that it will kill thepower supply. You would think there would be short protection
@ulwur
@ulwur 5 лет назад
Find it strange that a thermocouple would be 30-40 degrees off. Its a physical constant driving the voltage , and to get the metal alloy that off is remarkable. My experience of calibrating thermometers in a call lab leads me to believe it's a heat losses between the sensors (in the tip and in the tip thermometer) especially when the error seems to increase rapidly at high temperature where the losses is greater.
@TheDefpom
@TheDefpom 5 лет назад
yes it is interesting isn't it, they were good up to about 400 degrees C, I'm do know that certain thermocouple types can only work across certain heat ranges, which makes me wonder if these fake tips are using a tc that doesn't go over 400. OR my test instrument thermocouple doesn't go above 400 very well...
@crtech3955
@crtech3955 5 лет назад
Hi. I'm also testing this stations and tips, but my station is not calibrated the same way. What are your HW and SW versions? I have versions HW 3.00 and SW 3.02. There is a menu "Temp Adjust" that performs a similar procedure, but it seems that it don't work correctly (the real readings become even worse after calibration) and don't seem able to store per tip calibrations (not sure about that). The only tip I have with good results is the J02 and the best readings are after doing "Temp Init", that I belive reset the calibration values to the defaults. Cheers.
@TheDefpom
@TheDefpom 5 лет назад
CR Tech - I don’t remember off hand, but the review is linked in the description, I know I showed that info in the review so you will need to watch that video to see the versions on this unit.
@crtech3955
@crtech3955 5 лет назад
Hi. In fact I had seen your review video of than station before... You have the older one HW and SW 2.x, but it seems to be better than my version 3, do you know if one can change this firmware easily?
@Adrianvarz
@Adrianvarz 4 года назад
CR Tech I think not exist version above 2.1..version 3.x is fake. Last version from Ksger is 2.1. Maybe your version is equal with OLDER version from KSGER.
@Daniel-hd7gq
@Daniel-hd7gq 4 года назад
@@crtech3955 you probably had a kit. Version 3.x came only with DYI kits
@walter.casanova
@walter.casanova 4 года назад
@@Adrianvarz KSGER STM32 HW V3.10/ SW V3.1S, Aliexpress offical store
@chefbink61
@chefbink61 5 лет назад
I played around with this a bit because only 1 of my tips making it to 455c cal temp. It was a real Hakko JL02, but I have a few other real Hakkos that did not get to the 455c. After calibrating the tips I set the temp too 455 and all of the tips went to the set temp so I know the KSGER station can get to 455c with all of the tips. The only thing I can think of is that the cal points are predetermined set point looking for currant draw at a predetermined temp setting instead of looking at actual temp or voltage drop at the thermocouples. Anyway what ever they are doing it works well. All of the tips are with in 1-4 c of set temp with a few of them being right on the money. Anyway thanks again!! Regards, Spence
@Adrianvarz
@Adrianvarz 4 года назад
All the tips, if they are new..must be heated at 300-350 degree for one hour before start calibration.
@chefbink61
@chefbink61 5 лет назад
Thanks for showing this. I knew it could be done but wasnt sure how. The funny this is my KSGER was pretty spot on out of the box and was better then why real hakko fx951 but now it just blows away the fx951. Its with in 1 or 2 of set temp on all the tips I have even the cheap one I have from Banggood. I was playing around with it a bit and found that if you do a cal and let it stay on for a good 10 min or so and then do a recal you can even get it closer to the set temp... Anyway thanks again!!
@TheDefpom
@TheDefpom 5 лет назад
Yes it is good being able to calibrate it like that, very easy to do. I am not 100% sure that the >400 degree issue I had is the fake tips or the thermocouple tip tester I was using.. now I might need to buy another one to see.
@chefbink61
@chefbink61 5 лет назад
Yeah same here none of my tips got that high even the few hakko tips I have. They are T-15s but I really don't this there is much difference in the T-15s@@TheDefpom
@chefbink61
@chefbink61 5 лет назад
Oh I wanted to ask you if the handle that you have for your soldering station gets hot ? The one I have gets hot down by the grip and I end up having to move my hand. Thanks
@chefbink61
@chefbink61 5 лет назад
@@TheDefpom I just did a cal on a new JS02 tip (real hakko) and it went right to 461c in the 1st step so may be the element gets so weak over time that it just can't get there any more? Just a thought.
@TheDefpom
@TheDefpom 5 лет назад
@@chefbink61 - I use a metal handle, it seems fine I haven't noticed any issues with it getting hot. but then I tend to only use it for maybe 30 seconds at a time whilst fixing things. After a few minutes it goes to sleep and lowers its temperature.
@acoustic61
@acoustic61 5 лет назад
Will this station go over 400 C?
@Daniel-hd7gq
@Daniel-hd7gq 4 года назад
Yes
@whollymindless
@whollymindless 4 года назад
Mine won't do it on screen but my tips are all WAY over. Even after calibration it's all 50c over. (it never actually reaches the high temp for calibration, surely throwing things off)
@skullanclawbones
@skullanclawbones 3 года назад
Do you regret getting this station? I mean, I know there have been some issues you needed to resolve. I ordered it and then saw all the negative feedback. I'm a hobbyist, and I intend to see the earth ground fix added.
@TheDefpom
@TheDefpom 3 года назад
Not at all, my one has been perfect, it the best station I have owned, it works well and I have been happily using it for a long time now, I think the negative comments are from people picking up clones of this unit (or possibly different revisions of it).
@skullanclawbones
@skullanclawbones 3 года назад
@@TheDefpom I'm glad. I'll need to get the earth ground sorted out when I get it, and then see what happens from there. I have a list of items to check for after watching all the T12 T2.1s videos I could. Anyways, have good one.
@travisfrost6508
@travisfrost6508 3 года назад
I like mine, if you get the aluminium handle it may require some mods also but it is sooooo comfortable in the hand.
@demofilm
@demofilm 4 года назад
Maybe after a while the cartridge needs a seccond callibration
@pr0xZen
@pr0xZen 3 года назад
Advicable to run a new tip hot for 5-10 minutes before calibrating, at least the cheapo ones. They seem to be all over the place the first few minutes. To avoid unneccessary oxidation, you can coat the tip in solder before letting it sit those 5-10 mins. The original Hakko tips I have have all been pretty much bang on from start so I think those are "run in" during quality control. If you do this, the tip shouldn't chsnge unless it starts failing. But never hurts to do some spot checks once in a while.
@FineTuneCBShop
@FineTuneCBShop 5 лет назад
Whats up Defpom's .. forgive me if I'm wrong for calling you Scott, I'm not really sure what your first name is. Bruce Nitroxpro made a comment that I agree with. In my opining, if you talk slower the Yanks might be able to understand you a little better. Respect. It's almost perfect at .75 playback speed, speed of electrons must be a little faster on your side of the globe. lol
@TheDefpom
@TheDefpom 5 лет назад
you got my name right. yep I talk fast.. you should hear me when I get excited, or have had too much coffee.
@FineTuneCBShop
@FineTuneCBShop 5 лет назад
@@TheDefpom .5 playback speed? Hahaaa ... have a great day Scot.
@Daniel-hd7gq
@Daniel-hd7gq 4 года назад
How can you trust this cheap thermometer?
@helmuthschultes9243
@helmuthschultes9243 5 лет назад
More likely a limit of heater capacity than thermo couple error. If the heater has reached maximum power then no more temperature rise, thus a maximum temperature is reached
@TheDefpom
@TheDefpom 5 лет назад
Helmuth Schultes - the read back on the KSGER wasn’t lagging behind, so I believe that it is at the limit of the thermocouple range.
@tekk9995
@tekk9995 4 года назад
Don't forget to ground the station..
@TheDefpom
@TheDefpom 4 года назад
Tekk Ned - it already is grounded, check out the review video I did for it.
@BruceNitroxpro
@BruceNitroxpro 5 лет назад
If I could understand what you say, I'd probably learn something. I'm from America.
@FineTuneCBShop
@FineTuneCBShop 5 лет назад
Try .75 playback speed.
Далее
ПРОЖАРКА ХАРЛАМОВА
00:15
Просмотров 49 тыс.
Fake Hakko FG-100 soldering tip thermometer test.
8:11
KSGER T12 Calibration
5:36
Просмотров 29 тыс.
KSGER T12 Soldering Station a year later
10:25
Просмотров 39 тыс.
OZON РАЗБИЛИ 3 КОМПЬЮТЕРА
0:57
Просмотров 37 тыс.
YOTAPHONE 2 - СПУСТЯ 10 ЛЕТ
15:13
Просмотров 166 тыс.