In this video, we dive into the world of solar power with a comprehensive guide and review of a 12kW 3-phase solar inverter. Whether you're a solar enthusiast, homeowner, or business owner looking to harness renewable energy, you're in the right place.
🔌 Chapter Timestamps:
0:00 - Introduction
1:13 - Should You Go Solar?
2:10 - Solar Panels
5:30 - Installation Guide
12:49 - Inverter and Battery Setup
22:09 - Distribution Board
23:55 - Sunsynk App Explained
27:26 -Conclusion
Our goal is to empower you with the knowledge and confidence to set up your own solar energy system using the 12kW 3-phase solar inverter. We'll cover everything from the installation procedures to monitoring energy production and maximizing efficiency.
Throughout the video, we'll share real-world insights, tips for a successful installation, and expert advice on troubleshooting common issues. We'll also discuss the positive environmental impact of solar energy and how this inverter contributes to reducing your carbon footprint.
Whether you're considering a residential solar setup or exploring solar energy for your business, this video is your go-to resource. Join us on this solar power journey and take the first step towards energy independence and sustainability.
If you have any questions or want to share your own experiences, feel free to leave a comment below. Don't forget to like, subscribe, and hit the notification bell to stay updated on our latest content. Let's harness the power of the sun together!
Connect with us:
Twitter: / elecandall
Subscribe: ‪@ElecAndAll‬
#SolarPower #InverterSetup #RenewableEnergy
Certainly, including relevant tags and hashtags in your video description can help improve its discoverability on RU-vid and social media platforms. Here are some tags and hashtags you can use for your 12kW 3-phase solar inverter setup and review video:
Tags:
1. 12kW Solar Inverter
2. Solar Inverter Setup
3. Solar Inverter Review
4. 3-Phase Inverter
5. Solar Power Installation
6. Renewable Energy
7. Solar Panel System
8. Energy Efficiency
9. Sustainability
10. Green Energy
11. Solar Technology
12. Environmental Impact
13. Solar Energy Savings
14. Home Solar System
15. Commercial Solar
16. Solar Monitoring
17. Solar Maintenance
18. Solar Power Benefits
19. Energy Independence
20. Eco-Friendly Living
Hashtags:
#SolarPower #RenewableEnergy #InverterSetup #SolarInverter #GreenTech #CleanEnergy #SolarEnergy #EnergySavings #Sustainability #EnvironmentalImpact #EnergyIndependence #SolarPanelInstallation #EcoFriendlyLiving #3PhaseInverter #SolarMonitoring #SolarMaintenance #SolarTechnology #SolarPowerSystem #HomeSolar #CommercialSolar #SolarReview #SolarInverterReview #HonestReview #SolarPower #RenewableEnergy #GreenEnergy #EnergyEfficiency #SolarPanelSystem #SolarEnergy #CostEffective #investment #offgrid #offgridlife

Опубликовано:

 

7 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 32   
@dinesh031NLW
@dinesh031NLW 10 месяцев назад
Thanks brother. Really enjoy your videos. They have been really educational. I have no choice but to now install a solar setup. Last week we were 7 days without power. Due to an attempted cable theft by illegal miners. Theses outages have been occurring monthly in our area and to be honest it's only gonna get worse. If there's 2 or 3hrs loadshedding fine you can make peace with that but being cut off 7 days at a time? It's rediculous. Solar is the only way to go right now. I'm learning so much about solar and what to look for when going this route. Keep up the great work!! Your content is awesome!!
@ElecAndAll
@ElecAndAll 10 месяцев назад
Thanks for watching and for feedback bhaya
@derickkruger5680
@derickkruger5680 6 месяцев назад
Just to add to my previous comment / proposal, i love the fact that a South African comes up with this vid in the reality of our loadshedding environment. 👏👏 I, as i asume 95% of all normal non-electricians, have some basic questions, too many to post here, but as an e.g., i notice you also have a Jo-Jo water tank installed (that is going to be the nirm for 90% of houses in SA over the nxt 2 years due to our water problems), the pump/motor most probable switches on and off every 5 mins, which means the start-up current is a factor of 4x / 6x? the rated voltage on start-up and will have a dramatic impact on your power source ( e.g. a 1kw motor might draw 4kw / 6kw on start up for a couple if secs) so your inverter set-up should be able to handle that. How do you spec your system to cater for such peaks?
@ElecAndAll
@ElecAndAll 6 месяцев назад
First I used a DAB 2.5bar smart switch pump who was rated 600w. It didn't affect the system at all. Now I have a DAB VSD (variable speed pump) which adjusts the power according to demand.
@channelseptember6170
@channelseptember6170 7 месяцев назад
May God continue to bless you sir. Amen.
@ElecAndAll
@ElecAndAll 7 месяцев назад
Thanks for the prayers. Ameen
@CrazedCrittic
@CrazedCrittic 9 месяцев назад
Great video, just what I was looking for as I am moving house. New house has 3 phase and this is the inverter I was already looking at. Please can you do a review after a year? I would like to see your graphs as these inverters and batteries represent a notable capitol investment.
@dc1544
@dc1544 10 месяцев назад
I like how you say you have different facing panels like west and north. I have south right now 9400 watts and will add 1800 facing east. This is because in winter the sun is bright and sunny in the am in Michigan then around noon clouds roll in that is when my south panels should be at their highest production. I need that morning sun to help me out 4-5 kw a day. And I should get that.
@ElecAndAll
@ElecAndAll 10 месяцев назад
That makes perfect sense, being in the US and northern hemisphere. That will be similar to mine then being in the southern hemisphere
@MMMM2MMMM2MMMM
@MMMM2MMMM2MMMM Месяц назад
Why do you not use solar to heat your boilers? You could have used PVT panels to heat your boilers and heat the house by floorheating from the solar boilers too. Even the winters un SA have plenty of sunshine. (Been there)
@ElecAndAll
@ElecAndAll Месяц назад
Hello thanks where are you from? I do use solar to heat the water. Watch this video. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-_xClSxBWfqs.html
@goodnessnkuna9089
@goodnessnkuna9089 8 месяцев назад
Great video and very informative. My question is why did you decide to go full on 3 phase? I mean why didn’t you just stick with single phase and just buy a biggger inverter like 16 kva. What is the advantage of using 3 phase over a single phase because city power charge a monthly network optimisation fee?
@ElecAndAll
@ElecAndAll 7 месяцев назад
Ndaa, baramin. I'll explain why, I'm preparing another video.
@adon8672
@adon8672 6 месяцев назад
Nice video. How loud is the fan and at how many kw power draw/production does it come on?
@ElecAndAll
@ElecAndAll 6 месяцев назад
Loud enough to cause a nuisance. By 10am it's on while charging the battery around 9 kw's.
@phili200
@phili200 10 месяцев назад
I am just starting this journey.I am interested to know if you have installed your system yourself or if you use an installer.Did you choose and buy the hardware yourself.I do notice that buying the equipment yourself can work out cheaper but my concern is about warranty claims if something has to go wrong with the equipment.
@ElecAndAll
@ElecAndAll 10 месяцев назад
Hey Phil, Had everything professionally installed. I procured the panels, inverter and switchgear myself. That is a valid concern. You need to work whether the cost savings warrant the associated risk.
@zaydpeer
@zaydpeer 10 месяцев назад
Install it yourself at your own risk. Your insurance will sort you out when the time comes.
@ElecAndAll
@ElecAndAll 10 месяцев назад
@@zaydpeer correct advice. Let's showcase your setup.
@tsheponnene457
@tsheponnene457 10 месяцев назад
so why did you not connect the ct coil from the input on the db box ?
@ElecAndAll
@ElecAndAll 10 месяцев назад
Cos if I did, I wouldn't have been able to send excess power to the other 2 dwellings. Those dwellings are fed from the boundary main breaker.
@tsheponnene457
@tsheponnene457 10 месяцев назад
@@ElecAndAll i also noticed that you dont have any timer set on the inverter . . . Or a gyser timer. Based on that setup alone the max power you should be importing is 5kw. Id say have your gysers running at a higher temp during the day and perhaps blanket them the solar power you getting during the day should be high enough to warm up the gysers and it would be warm throughout the night...
@ElecAndAll
@ElecAndAll 10 месяцев назад
@@tsheponnene457 remember that that it depends on the number of people in the house that creates a higher demand. This is not possible during winter in Joburg since the water almost freezes. Each time hot water is used, ice cold water enters the geyser and rapidly decreases the temperature of the water. Watch this video where you will see what I mean. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-_xClSxBWfqs.html. I have a timer for geyser.
@dc1544
@dc1544 10 месяцев назад
1 14 kw battery and 8kw more solar panels and you would be off grid 10-11 months a year. those other panels could be Grid tied inverter so first it would charge and supply loads but when batteries are full and loads are met by other inverter it could sale to the grid and when you need extra it comes off your credit so you would never have a bill again.
@ElecAndAll
@ElecAndAll 10 месяцев назад
Watch this space, I'll show you an alternative without building on solar capacity
@dinesh031NLW
@dinesh031NLW 10 месяцев назад
Once I had a situation were I left work coz there was Stage 5 loadshedding. Only to try and work from home. By the time is reached home. Now our area has loadshedding. Lol It's madness.
@ElecAndAll
@ElecAndAll 10 месяцев назад
That's unlucky bhaya!
@capebee4839
@capebee4839 10 месяцев назад
Your batteries seems to have a low C rating You should be able to draw almost 300 Amps from three 5.3 kWh batteries with a C rating of 1 But yours seems to only have a C rating of 0.5 I think that this is why your inverter tripped with the geyser Also you didn't need to take your current transformer to your Eskom meter box Your could have just put it on the incoming side of your main switch in your main DB
@ElecAndAll
@ElecAndAll 10 месяцев назад
No. The inverter has a current limit on AC side of 23Amps. 4kw element pulls abt 17amps. If another load comes on then that's a shortcoming on this inverter. I have 2 phases feeding from the main feed on the boundary. There's no way the CT will detect and supplement those from the house DB. Correct, batteries are 0.5c. I don't need more than that for this bank. I'm not using the max power from the panels. Also 1C have their own shortcomings. We limited the current draw to 200amps from the bank of which we haven't reached. ☺️☺️
@andriesappelgryn6517
@andriesappelgryn6517 10 месяцев назад
These batteries do have a 1C rating, and he has flats on the property as well. That is why he took the CT to the main incomer, so the power the consume can also be fed by solar to an extent.
@capebee4839
@capebee4839 10 месяцев назад
@@andriesappelgryn6517 the regulations here are that you may only have one main switch So your main switch would then normally be in the main house ESKOM supply is not a main switch The only time that you are allowed to take seperate supplies directly to separate buildings is if they are on a separate ESKOM or Council meter If there is only one Eskom meter for the property, then you may only have one main switch The supply must go from the Eskom meter box to the main DB with the Main Switch This in theory could be right next to the Eskom meter box, but not inside it
@capebee4839
@capebee4839 10 месяцев назад
Also if you look at the specs if the battery, it says max discharge of 100 Amps, which on a 5,3 kWh battery is just under 1, but more importantly, it says that the recommended discharge current is only 50 Amps for one battery and 100 Amps for batteries in parallel I don't have any experience with this particular battery, but on some batteries, the 100 Amps limit is because of the proprietary battery cable supplied with the battery that only has a rating of 100 Amps So for three batteries, if you were making use of the proprietary cables, you would have to run two sets of cables back to the inverter to use more than 100 Amps if you had 3 or more batteries Same limit as for Pylontech. Thanks why when using many Pylontech batteries together, it is then better to run each battery to a busbar and then much thicker cable, depending on current rating of the inverter, back to the inverter
Далее
Sunsynk Inverter Training (Basic)
1:00:17
Просмотров 51 тыс.
How to Choose SOLAR Wisely and Avoid Costly Mistakes
25:40
We had NO CHOICE but to go Off-Grid
13:57
Просмотров 2,3 тыс.
SunSynk Work Modes Setup
15:40
Просмотров 63 тыс.
Brief introduction to Battery systems
23:34