2020 changes series: Article 392 

Ryan Jackson
Подписаться 30 тыс.
Просмотров 9 тыс.
50% 1

Опубликовано:

 

28 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 20   
@jordanharris3553
@jordanharris3553 3 года назад
One of the cutest intro as I’ve ever seen!
@johnkulpowich5260
@johnkulpowich5260 3 года назад
Can't stand the wannabe electricains on you tube. Your one of the best
@mattmclaughlin7338
@mattmclaughlin7338 3 года назад
thank you ! your content is very much appreciated. if you could produce a video like this every day . I'm sure youtube algorithm will pick up very fast like it did for Daily Electrician.
@davem5392
@davem5392 2 месяца назад
Ryan do you have to attached RMC to the tray when exiting or entering 392.18G seems to say this????? You have a couple pics in the video with the conduit not attached to the cable tray
@Voltage06888
@Voltage06888 2 года назад
Awesome!!! Thanks Ryan 👍
@j81851
@j81851 2 года назад
Cable tray is a UL listed for the purpose and is a RACEWAY just like conduit. This is very important. Loose cable or jacked cables must be TC or Tray Cable rated required. UV or sunlight resistant is required. As always it must be installed per the manufacturer's recommendation and per listing and labeling. Thanks for you content it is very good however at any time we discuss tray I suggest we review the unique status of this type of raceway.
@RyanJacksonElectrical
@RyanJacksonElectrical 2 года назад
It isn't a raceway.
@jacobbotden5641
@jacobbotden5641 3 года назад
I've thrown out many handfuls of those type S ties that loose their teeth immediately on first use just like the crappy ones.
@felixsandoval486
@felixsandoval486 3 года назад
Is there anything like "Commercial building" where conditions of maintenance and supervision ensure only qualified persons service the installed cable tray system? If so, could it be considered to install individual conductors on their cable trays?
@RyanJacksonElectrical
@RyanJacksonElectrical 3 года назад
No, although I my opinion there should be. There were several proposals for the 2023 to change the concept to "restricted access locations," but those proposals failed. The proponent for these changes works at a national laboratory that has more stringent requirements than most "industrial" facilities but cannot use the allowances.
@felixsandoval486
@felixsandoval486 3 года назад
@@RyanJacksonElectrical Ok. As usual Sir, great information, useful and clear. Thanks a lot. Already waiting for your next publication.
@vishalgulati5847
@vishalgulati5847 2 года назад
Thank you very much for this Video. may you please help me out for short questions :- 1. is it mandatory to install cover on ladder type cable Tray ? cable tray will be installed in a metallic container. and not approachable to user. 2. if Cable is not Tray Type listed, but approved with UL: AWM 10107 & NFPA79. can we install such kind of cable in Cable Tray ? The cable is for example ÖLFLEX FD 90/90 CY which is flexible power cable to connect the machine. Installation is in Metallic container and Length is not more than 10meter. 3. I also heard that it always depend upon customer to customer and area to area by which standards they want to inspect. it can be NEC or can be NFPA79. with NFPA79 its not an issue to install not listed Type cable installation in cable Tray But with NEC, yes its an issue. is this true ?
@LordVoltRod2c
@LordVoltRod2c 6 месяцев назад
10:35 It will soon be raining snakes!
@fdrestates
@fdrestates 3 года назад
Hello Sir..thx for the video. I have a legitimate question. Where would I find in the code that a cable tray assembly must be identified for that particular application but does not have to be listed? Thank You! (Cable tray or any other material for that matter) Sidenote: I used to work in telecom years ago.. these are quite common in that industry and for outdoor cells all of the antennae transmission lines are supported by cable trays.. lots of temperature changes there
@RyanJacksonElectrical
@RyanJacksonElectrical 3 года назад
The last sentence of 392.10
@TheJoypool
@TheJoypool Год назад
Can lv cables cross @90 degrees over each other on cable trays?
@chrishull1993
@chrishull1993 3 года назад
Good content. Really enjoy the code updates. Only thing would be to grt a better mic
@RyanJacksonElectrical
@RyanJacksonElectrical 3 года назад
Thanks for the feedback. The embarrassing truth on this video is that after I shot I realized that my mic was moved from where I normally put it. I had mopped the floor earlier and moved the mic stand, then didn't put it back. 😑
@chrishull1993
@chrishull1993 3 года назад
Completely understandable. I just think that the use of a pop filter is underrated and the room echo is a little rough when I'm listening on my van speakers omw to work
@RyanJacksonElectrical
@RyanJacksonElectrical 3 года назад
@@chrishull1993 I use a pop filter as well. In fact, you can see it in the video I did yesterday Thanks again for the feedback, I really do appreciate it.
Далее
2020 NEC changes series: 110.14 Conductor Terminations
23:28
나랑 아빠가 아이스크림 먹을 때
00:15
Просмотров 5 млн
Chelsea gym be like.. 😅⚽️
00:20
Просмотров 14 млн
How to Install TRAYCAB Cable Trays
7:00
Просмотров 177 тыс.
Article 724 Class 1 Circuits
13:03
Просмотров 2,5 тыс.
Working space in the 2020 NEC
22:18
Просмотров 10 тыс.
26207 Cable Trays   Video Lecture
23:01
Просмотров 1,7 тыс.
Current carrying conductors in the 2020 NEC
22:04
Просмотров 38 тыс.
wire pulling in cable tray
4:40
Просмотров 3,5 тыс.
나랑 아빠가 아이스크림 먹을 때
00:15
Просмотров 5 млн