@miket611
@miket611 Год назад
I have four of these hooked up to a 48V battery. My limiter wiring is 2 ct clamps in parallel and then all the limiter plugs read the same info in parallel. Everything seems to be working fine, but the output from my inverters doesn't seem to be lining up to the amount of power being consumed even when they are more than adequate to cover the load. In this video you say to hook up the third leg to ground , but in my setup I hooked the middle or third leg to neutral. Is this the problem? Somehow I get the feeling that split phase is working against me like it is cancelling itself out or something weird. Any ideas?
@actionnew
@actionnew 3 месяца назад
We have the 2000 watt version however it stopped working do they have an internal fuse it says lifetime warranty what's the page on Amazon disappeared thank you in advance
@Yahgiggle
@Yahgiggle 3 года назад
this model has a fault with how the bottom fans blow air onto the PCB at the bottom, if that air is cold it can cause condensation build up on the lower area and then short the PCB out or cause the traces and components to fail due to corrosion, i feel if they had the fans not so close to the pcb or coat that area to protect it the problem may be mitigate, the 1000watt units don't seem to suffer the same problem
@aedgvv6095
@aedgvv6095 3 года назад
, i have a same unit, the total KWH and Today KWH in ENergy view is stuck at zero, i did a factory reset, i contacted sells MarsRock he only offered to by the wifi adapter from him. Any suggestions? Thank you so much
@pkefvkef4856
@pkefvkef4856 Год назад
hello My friend. I have a very importnt question for you.whichi beleive other people surely have also.These 2 Kw sun ON-Grid inverters work perfectly.But many problems arrise when grid is off.from various reasons. A. service,fault in the line, fire, strong winds etc.....My question. Can i create my personal Grid so the inverters can smell electricity of 220 volts????And since i have one per phase cause i have 3 phase system. Do i need an off grid inverter of 6KW in total power???I am little confused.If my on grid inverter is 3 x 2 kw power each [3 of them] the off grid inverter has to be similar in power?? 3 phase 3 x 2 KW. OR i can even do my ignite voltage with a smaller 3 phase off grid inverter??In other words how electronically get into the ignite system and say to on grid inverter despite the fact that city Grid is off ,Eiii you have voltage 220.....operate....Thank you so much
@John-brc20
@John-brc20 9 месяцев назад
Hello, thank you for your videos.😊 so,Can I have 2 inverters 1kva , and plug them to my grid plug? Also, about the limiters, 2 inverters I have 2 limiters, is ok to add 2 limiters on my main wire so i dont exporting power back into the Grid? It will works? Thank you so much
@pkefvkef4856
@pkefvkef4856 2 года назад
My friend.I have a 2 KW on-grid inverter 220volt AC.The incoming voltage from solar panels is 68v DC and the amperage is 30 Ampere.My upper voltage incoming from solar MUST BE LESS than 90 volts.Is a protection the knowledge of the existing panels that offer 68volt enough OR i have to install an upper /lower voltage controller for the panels DC incoming voltage???Is there a device that i can adjust Max permissible incoming voltage = 90 volts ????Thank you
@sang3Eta
@sang3Eta Год назад
You can adjust the volts/amps by putting solar panels in serial or parallel. What is theAmp range of the inverter? 2000W/45V = 44A or 2000W/90V = 22A? 68V x 30A = 2040W is in that range so probably works.
@penrodautorepair3170
@penrodautorepair3170 4 года назад
The sensor won’t work right in the states. Their is a guy that makes one with two leads that detect both side of power coming in.
@SolarEngineering
@SolarEngineering 4 года назад
yeah, checkout 2nd part of this video (link in description). I'm going yo make my own cable for about $20.
@penrodautorepair3170
@penrodautorepair3170 4 года назад
Please make that video. I’d love to save cash.
@penrodautorepair3170
@penrodautorepair3170 4 года назад
I need one for two inverters
@SolarEngineering
@SolarEngineering 4 года назад
@@penrodautorepair3170 yes, this will be in Part 3
@sakhumtang1
@sakhumtang1 4 года назад
I really want to see your next video see if it works. I get one from ebay and get other from Amazon I hook up 48v with 4 batteries 200ah each battery but is keep say grid error doesn't know what happened please up load your next video thanks.
@SolarEngineering
@SolarEngineering 4 года назад
Sure! I'm preparing for the video. I did all research and it will work. Video will be soon.
@juanpena5993
@juanpena5993 2 года назад
Same problems
@interestingthings5829
@interestingthings5829 10 месяцев назад
Is your inverter still working? I'm trying to see how durable it is before I buy one
@SolarEngineering
@SolarEngineering 10 месяцев назад
I sold it after one year and installed Sol-Ark. One of the inverters lost cooling during this year.
@pkefvkef4856
@pkefvkef4856 2 года назад
My friend.I have 3 on-grid inverters with limiter.Each inverter has a limiter with a twin cable.As far as i have connected the limiter i secure the the gird -meter doesnt go back.Ok.Question.Now As the inverter is on operation,If i cut the line in the twin cable of the limiter ,will the grid meter write backwords??And if it does so can i regulate with a timer a specific time in the day say from 9 to 10 in the morning to turn back the grid meter???
@SolarEngineering
@SolarEngineering 2 года назад
I'm not using these inverters anymore, I think you can easily answer your question by simply disconnecting limiters from inverter and see how inverter behaves.
@pkefvkef4856
@pkefvkef4856 2 года назад
@@SolarEngineering do you happen to know AFORE On grid inverter 6kw .Are these good??Or what type of inverter you use now??I am interested.
@SolarEngineering
@SolarEngineering 2 года назад
@@pkefvkef4856 I'm using Solark. Not familiar with Afore.
@sang3Eta
@sang3Eta Год назад
Dumb digital meters only go forward, only the old analogue disk ones could go backward. Smart meters can read in both directions.
@sosaprojecta9773
@sosaprojecta9773 3 года назад
Hi, I want to connect a 24 volt lifepo4 accu pack how can i get the voltage to 48 volts?
@SolarEngineering
@SolarEngineering 3 года назад
it's going to be better to get a 24V inverter. Or you can connect two 24V batteries in series.
@sosaprojecta9773
@sosaprojecta9773 3 года назад
@@SolarEngineering ah thanks
@sang3Eta
@sang3Eta Год назад
I believe they have a 1000W version of this inverter that works with 24V. I'd rather buy a 48v battery though and use 2000W.
@cliffBMRC
@cliffBMRC 2 года назад
Can you attach 48V battery bank (100AH each) directly to the + and - terminals of the SUN-2000GTIL2-H ?? Please advise...Thank you. I connected 48V battery bank to the + and - correctly and blew the unit??? Any suggestion. My unit is the 2000W Grid Tie Inverter Power Limiter LCD Display DC50-90V Solar Input AC185-265V Output SUN-2000GTIL2-H
@SolarEngineering
@SolarEngineering 2 года назад
yes, you can connect battery to the inverter, not sure why it blew unit in your situation.
@cliffBMRC
@cliffBMRC 2 года назад
@@SolarEngineering Thank you for your insight. After careful review, I believe + terminal was shorted out by terminal cable end grounding out with the "REMOTE" port which is extremely close to both + and - inverter connections. Much Appreciated.
@sang3Eta
@sang3Eta Год назад
Mixing polarity will blow the unit up. You can also damage your battery and terminals by not using a resistor to pre-charge the capacitors (makes sparks fly).
@pkefvkef4856
@pkefvkef4856 Год назад
Hello My friend.Hope you are well.Please can you tell me where i can find the LCD display of the 2KW grid tie inverter.The display has characteristics 3202020391 24 TFT LCD VERT5 2018-12-06 Thank you very much
@pkefvkef4856
@pkefvkef4856 Год назад
My dear friend.I have One and only question for you because the company tells me to read the manual.but Nothing is written on that.I have the 2 KW on grid tie inverter with limiter.I have started operating it and it works normally as an On grid inverter.I achieve full power 1550 volt.,without having connected the limiter.Now 2 days i try to connect the limiter and it shows that the inverter produces 25 watt and grid gives 12 watt.Nothing more.Despite the fact that i use an aircondition too.My QUESTION.At the only screen that this inverter has do i have to define the a) max Ampere of it b) the power produced 2000 W ?????thank you so much.respect Pavlos
@SolarEngineering
@SolarEngineering Год назад
Hi there, you can set amperage or wattage. If inverter reads 25 watts when consumption is bigger, then check CT sensor wiring.
@pkefvkef4856
@pkefvkef4856 Год назад
@@SolarEngineering CT sensor has got 2 wires.the only think if the readig is negative i turn the sensor so the arrow looks in the opposite direction.and then the reading is corrected.
@pkefvkef4856
@pkefvkef4856 Год назад
Do you mean that i have to cut the cable of the sensor and connect the 2 cables the other way ??? Anyhow when the ivrter is in limited mode at the screnn that you see everything ,the only detailed screen they have. WHAT do i choose A.Amperage details Or Watt details.Which one has to have the tick and be visible.??? And as they say this is the limit.I try to guess that and in watt [ imust place the max power that the inverter gives 2000 wattt and in amperage i must choose the maximun output in ampere that the inverter can give .which for 2000 = 9 Ampere.
@sang3Eta
@sang3Eta Год назад
Turn the sensor the other way around so the arrow points the other way.
@pkefvkef4856
@pkefvkef4856 Год назад
Dear friend.I have installed 3 x 2 KW SUN on grid inverter with limiter.They work fine.BUT.when city Grid goes off then finito.I do wonder.Can I not create my personal grid so inverters smell that exists voltage of 220 Volt with frequency 50 Hz.using 3 mirrors and 1 KW off grid inverter with a small battery????In case that the city grid goes off.Can i not use in the 3 inverters the same input from the off grid inverter.Note...that despite the fact i have a three phase city grid voltage i never use the advantage of the 3-phase voltage.I never have a 3-phase motor.Note also that i will use a transfer switch to discriminate the actual voltage source of the house.Position 1 city grid. Position 2 .My personal Grid.I would respect your expert opinion.Thanking you in advance my friend.cheerio
@sang3Eta
@sang3Eta Год назад
Self islanding is a safty feature for people working on the grid. You need to use an off grid inverter for what you want and run plugs off it to where you need them.
@sang3Eta
@sang3Eta Год назад
This video maker has the same problem and solves it with a very expensive SolArk hybrid system. Made a video about it ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-yGWc1_Ujbq0.html
@sang3Eta
@sang3Eta Год назад
I have found MPP Solar all in one charge controller. Mains, battery and solar input. Off grid but can draw power from the grid if battery and solar low. I'm thinking put one between the grid and the fuse box. Better quality and not much more expensive!
@John-brc20
@John-brc20 9 месяцев назад
Hello, how you install the limiters sensors? I have 2 of them, so I have 2 limiter sensors, I should plug them on my main grid and the 2 of them? Or is any other way to use 1 limiter for 2 inverters? Thank you 😊😊