Тёмный

Aurora ground fault and service password problem 

Andy Reynolds
Подписаться 24 тыс.
Просмотров 1,3 тыс.
50% 1

A 2Kw aurora with ground fault and battery problems.
Help out: www.paypal.com...
/ windandsolarelectricity

Опубликовано:

 

27 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 37   
@BuyitFixit
@BuyitFixit Год назад
Hi Andy, Great Video! Thanks for the shout out! That is a very strange fault on the 2kw inverter. The RS485 connections are just the + and - but on the interface I got from amazon it had the GND wire too (which is marked RTN on the Aurora) so 3 wires. I just used some wires that are commonly used on Arduino microcontrollers (Dupont connectors, and just poked them onto the pins). The interface I used was from Amazon "Waveshare Industrial USB to RS485 Converter" around £17. Hope that help! Oh and the service password for your 3KW inverter SN:991350 should be 880460 :)
@TheInfoworks
@TheInfoworks Год назад
Mick, thanks for this info. I really should gain some experience in this, but you know how it is. Cheers
@TheInfoworks
@TheInfoworks Год назад
Mick, all parcelled up and I've sent you an email, cheers
@BuyitFixit
@BuyitFixit Год назад
@@TheInfoworks Thanks Andy!
@BuyitFixit
@BuyitFixit Год назад
@@TheInfoworks I've sent the label Andy. Cheers!
@TheInfoworks
@TheInfoworks Год назад
@@BuyitFixit splendid, I'm on to it, cheers
@XXXXIndices
@XXXXIndices Год назад
Did you try the 029249 serial number shown on the display?
@TheInfoworks
@TheInfoworks Год назад
Hi, yes, but to no avail, there's something adrift with this unit, cheers
@Woodyjims-shack
@Woodyjims-shack Год назад
FYI Andy I have a 6kw Aurora with a GFI fault and last time I tried to start it I saw a battery low warning also. I know a dealer who might give out an official password!
@TheInfoworks
@TheInfoworks Год назад
Jim, interesting, so you think the two faults are connected. The passwords are individual and so a right unnecessary hassle, cheers
@BuyitFixit
@BuyitFixit Год назад
"Official Password?" - the algorithm is the same, if the dealer generates it, or you use aurora's CVI software (unlocked with their engineer password of "91951") or use the keygen I wrote. The numbers will be identical. You can even work it out with pen and paper! (see comment below).
@BuyitFixit
@BuyitFixit Год назад
Could the GFI faults possibly be related to the 3 pin MOV's that seem to be on the input side of the inverter? Anyone tried removing them to check?
@TheInfoworks
@TheInfoworks Год назад
@@BuyitFixit Mick, I swapped the thermisters to no result. If you would like this unit I can parcel it up if you send Evri (Hermes) to collect it. The local Evri rep knows where we are and where I leave things. Jim thinks the 2 symptoms are related, cheers
@TheInfoworks
@TheInfoworks Год назад
@@BuyitFixit Mick I will sort that and confirm the weight, should be in the 10 to 15Kg range (might be a few days as we have visitors). Victron inverters are reliable, we now have 5KW multi, and it is set to look after the batteries but only run at a max of half capacity, that way all will have a long life. Just been looking at an Afore 2.7KW with a dead short, turns out to be 2 of the 4 fets. They are K30H603, would K50H603 be a replacement as I have several? Cheers
@mrgadget28
@mrgadget28 11 месяцев назад
Where do i get the password generator.
@TheInfoworks
@TheInfoworks 11 месяцев назад
hello, are you asking a question or demanding?
@mrgadget28
@mrgadget28 11 месяцев назад
@TheInfoworks Hi sorry didn't mean to write it abruptly.Did you manage to get password to work.
@TheInfoworks
@TheInfoworks 11 месяцев назад
@@mrgadget28 Hi, I got the details from buyitfixit, he did a video on this very thing, however I had no success with the passwords he provided, however he did go through the process, cheers
@Woodyjims-shack
@Woodyjims-shack Год назад
Ps I can communicate via rs485 with my other inverter. It needs a fairly expensive USB to re486 adapter. Others may work but I was told just get a proper one. Its a three wire connection.
@TheInfoworks
@TheInfoworks Год назад
Jim, do you know how the wires go? cheers
@TheInfoworks
@TheInfoworks Год назад
@@Woodyjims-shack Jim, thanks for looking out these details, web searches are sometimes quite difficult, cheers
@XXXXIndices
@XXXXIndices Год назад
I have a cheap usb to RS485 from Aliexpress and it works fine, only cost a few dollars. It has just 2 screw terminal A and B just connect A to A and B to B, if you have multiple devices connected it needs to have the 120 ohm resistor in just the 2 devices at each end. If you are just connecting your PC to one inverter just run a twisted pair of wires A-A and B-B and it will work with the ArouraCVI software that you can download via the link from buyitfixit's video.
@younasshah6204
@younasshah6204 Месяц назад
Nation pasward please
@TheInfoworks
@TheInfoworks Месяц назад
I don't have it, try BUYITFIX channel, but be polite not demanding
@g7mks383
@g7mks383 Год назад
Well Andy that was perfectly timed. Yesterday my Aurioa Uno stopped working and showed a RISO high alarm. I have two seperate banks of panels 10 and 6. I found by disconnecting each bank that the 10 panel bank is suspect. Problem is they are on the house roof. So scaffolding required. So disconnected them and now running on other bank of 6 panels. Suspect rain has got in somehow. So very interested to see your progress in disconecting the ground. Thanks for you info. As you know we have been abandoned by Arrouria and ABB.
@BuyitFixit
@BuyitFixit Год назад
And Fimer as the email I received from them was what prompted me to reverse engineer the password calculation.
@donchevgeorgiev7687
@donchevgeorgiev7687 Год назад
this error refers to the AC side of the board, most likely there is a faulty capacitor. Check them externally and if necessary measure them with a multimeter.
@TheInfoworks
@TheInfoworks Год назад
Yes, tricky things to measure unless removed, cheers
@bootsowen
@bootsowen Год назад
I have taken to writing the passwords for stuff like this on the front or the side in permanent marker.
@TheInfoworks
@TheInfoworks Год назад
Owen, good policy as these passwords are just another way of adding redundancy, cheers
@bootsowen
@bootsowen Год назад
@@TheInfoworks I had a look at buyitfixit, he gets into the software side pretty deeply. Good to know that this resource exists!
@TheInfoworks
@TheInfoworks Год назад
@@bootsowen definitely, I may end up donating this aurora to him, cheers
@XXXXIndices
@XXXXIndices Год назад
Andy I have just been fixing up a few of these inverters to use with my off grid system. When you put the serial number in to get the password just click ok, not the generate password button. Doesn't make sense I know but just click the OK in the top section and the password will appear, Click generate password and it says wrong password. Also the ground fault could be a failed RED MOV just above the DC inputs on the PCB. It will give a RISO error if not installed, try taking a couple out of a working inverter and put them in the one that is giving you grief.
@TheInfoworks
@TheInfoworks Год назад
Gary, interesting, I will try this on another unit, how do you use these off grid? cheers
@g7mks383
@g7mks383 Год назад
Hi Andy back again with an update. After proving that my 10 panel section is causing a high ground fault on my inverter and as mentioned the panels are on my roof. I decided to have a go with an old trick we used in Strowger Telephone Exchanges when the Boss was'nt looking. We often got resistive ground faults due to oil getting dirty and tracking to earth. So we made a 10 ohm wire wound resister and a probe connected to the 50 volt supply then probed the suspect areas on the earthy side. Quite a current would breifly flow and hay presto blasted the contact away. So I decide just to short out my panels when the sun was shining. Result now no RISO alarm and all panels producing. Saved the Scaffolding for now.
@TheInfoworks
@TheInfoworks Год назад
Brilliant, that warmed things up and improved the contacts, worth remembering, cheers
Далее
Afore solar inverter, dead short fault.
28:20
Просмотров 1,6 тыс.
ТАРАКАН
00:38
Просмотров 209 тыс.
Smart Meter Disaster!!
16:33
Просмотров 427 тыс.
How 3 Phase Power works: why 3 phases?
14:41
Просмотров 1,1 млн
Google Pixel 9 Pro Fold Is So Good! But…
11:55
Просмотров 1,7 млн
I took the #1 Tech Exam and it was BRUTAL
18:28
Просмотров 1,2 млн
How To Identify An Unmarked or Blown IC Chip
32:31
Просмотров 63 тыс.
Inside a smart meter, and the REAL problem with them.
16:45