Bolted Connection | Eccentrically Loaded | Safety Factor | FEA for beginners | SolidWorks Simulation 

CAD CAE Lab
Подписаться 1,8 тыс.
Просмотров 11 тыс.
50% 1

This tutorial is the beginning of the connector series. Today we will go over bolts connection safety factors and finding critical bolts using the connector feature in SolidWorks.
Hope you enjoy it!
Learning Outcomes from this video:
• Setup assembly for bolted connection simulation
• FEA (Finite Element Analysis)
• Critical load and safety factor
• Stress and safety factor
• Read and modify results
• Presenting FEA results in a desired format
Thank you for watching! Enjoy!
/ @cadcaelab
#boltedconnection
#criticalbolt
#bolt
#fea
#finiteelementanalysis
#plate
#linearstatic
#simulation
#solidworkstutorial
#solidworkssimulation
#begginers
#mesh
#globalmesh
#local interaction

Опубликовано:

 

5 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 12   
@romanmoreno9665
@romanmoreno9665 Год назад
Hello, why you didn't specify preload? Here bolts work as a pin.
@The.Talent
@The.Talent Год назад
M16 bolts have a pitch of 2, which means 1 thread every 2 mm, or 0.5 threads per mm, not 2 threads/mm as shown. Very helpful video!
@fra2025
@fra2025 5 месяцев назад
wow! thanks a lot!
@cadcaelab
@cadcaelab 5 месяцев назад
You're welcome!
@fra2025
@fra2025 3 месяца назад
​Sorry, ​@@cadcaelab, Is It necessary to suppress coincident mate before starting simulation?
@三好伸一
@三好伸一 Месяц назад
Hi, I was looking for how to do the analysis and came across this site. It is very informative. I would like to ask you one question. At 12:41, it says FA=FB=21.0KN, FC=FD=14.8KN. How do you get these values in a normal calculation? If you don't mind, could you please tell me the equation?
@med7756
@med7756 5 месяцев назад
Hello shouldn't the load be concentrated on the halfway distance of the 15 thickness? If so how you put load of 16 Kn totally distributed along the edge.that means that you should multiply this uniform 16 Kn load by 15 to get the equivalent point centered load. Am I correct?
@emrecan.daglii
@emrecan.daglii 4 месяца назад
Hi, why we see bending moment result on bolt? We check bolts as per code (EN-AISC etc.) and i cannot see bending moment check there? Could one explain it ?
@wilsonyucra7979
@wilsonyucra7979 Год назад
de que libro son los ejercicios por favor
@cadcaelab
@cadcaelab Год назад
Shigley's mechanical engineering design 10th edition.
@elliotmadison1928
@elliotmadison1928 Год назад
I wirk through this entire thing and you put the force on a face that I don't have because of how you make the parts? Like why would you not show how to do this the other way?
@三好伸一
@三好伸一 Месяц назад
Hi, I was looking for how to do the analysis and came across this site. It is very informative. I would like to ask you one question. At 12:41, it says FA=FB=21.0KN, FC=FD=14.8KN. How do you get these values in a normal calculation? If you don't mind, could you please tell me the equation?
Далее
PLC Basics: Ladder Logic
26:20
Просмотров 380 тыс.
Пчёлы некроманты.
00:46
Просмотров 26 тыс.
Bolt Pretension Analysis using Solidworks Simulation
9:07
The Incredible Strength of Bolted Joints
17:58
Просмотров 3 млн