Bypassing a Furnace Control Board with a 90-340 Relay to get Blower Running 

Apartment Maintenance Pro
Подписаться 38 тыс.
Просмотров 17 тыс.
50% 1

Not DIY advice. This is just myself diagnosing a control board for a furnace that would not let the blower motor run. I bypassed the blower motor fan part of the faulty control board with a all purpose 90-340 relay for a temporary fix to get the cooling going.

Хобби

Опубликовано:

 

18 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 37   
@richlikeg3722
@richlikeg3722 Месяц назад
This video saved a customer from the heat of Texas. Her motherboard burnt up and I had to bypass it. I had a 90-340 in the truck and I hooked it all up. She was cooling within the next hour. Get it done fellas, I never used on before.
@AaronPowellvox
@AaronPowellvox 10 месяцев назад
I like that method. I usually straight wire the fan until I can get them a new board but your method allows for the fan to run with everything else like normal until you can get a new board.
@jaykeller1
@jaykeller1 6 месяцев назад
So far this is the best video I have seen for peforming this temperary fix.
@TheRicardo7500
@TheRicardo7500 9 месяцев назад
This is an amazing video, straight to the point, you made it look easy. Thank you so much!
@wilmercruz3889
@wilmercruz3889 10 месяцев назад
I love your videos man, I've been working as maintenance tech for a couple of years and your content has helped me a lot.
@ApartmentMaintenancePro
@ApartmentMaintenancePro 10 месяцев назад
Thank you wilmer I appreciate it :_
@benjamintimmins1656
@benjamintimmins1656 10 месяцев назад
You're a hell of a tech bro! I've never used a relay just a contactor or actually what I like to do it hook the fan speed up to the door switch....but good job. Now I know how to do it!
@ApartmentMaintenancePro
@ApartmentMaintenancePro 10 месяцев назад
Thanks Benjamin I appreciate that 👍
@gotchaplumber
@gotchaplumber Месяц назад
Great video!
@bawipengcin8591
@bawipengcin8591 8 месяцев назад
Thanks for sharing and teaching
@user-mb5cr1ts8g
@user-mb5cr1ts8g Месяц назад
Oh mugid was about time someone did it so simple
@MsFishingdog
@MsFishingdog 6 месяцев назад
Good job.
@esbonwordenjr6069
@esbonwordenjr6069 9 месяцев назад
Just for future as long as you dont have an ecm fan motor you can take your heat wire off and put it on the EAC terminal which will also do the same thing without having to add a whole seperate relay because the eac is electric air cleaner which has its own relay to turn on when the furnace turns on.... ive done it multiple times till i get a new ifc board.... or you can unsolder the relay from the board and solder on a new one if u got it which most people wouldnt so just pull the wire off and put it on eac terminal which is a 120 terminal...... let me know if you have tried this before
@markharris9647
@markharris9647 8 месяцев назад
I'm a new tech I will try that can you make a video for me
@Niafi11
@Niafi11 5 месяцев назад
I just need to know if i can use 90380 instead of that 90340. Its all i got and its the Weekend. I guess im gonna have to wait til Monday
@BridgeWater94
@BridgeWater94 10 месяцев назад
Question. How are you able to work on hvac equipment and get supplies? I’m doing maintenance right now and they want me to work on some hvac equipment. The problem I’m running into is I can’t get into supply houses for equipment. What can I do to get into supply houses assuming your able to? Do you have a mechanical contractors liscence for hvac? I’m stuck on how to go about this
@ApartmentMaintenancePro
@ApartmentMaintenancePro 10 месяцев назад
My company has an account with Johnstone so I can walk in there . We also use a mechanical contractor to get us supplies
@viper22304
@viper22304 3 месяца назад
thanks for sharing. awesome work. Question: if you were to use the low speed (heating), where would you connect it to the relay?
@ApartmentMaintenancePro
@ApartmentMaintenancePro 3 месяца назад
Remove your speed wire hooked up and place the low speed wire in its place. Ensure the speed wires are insulated or strapped up
@jorgedelaossa9899
@jorgedelaossa9899 9 месяцев назад
Thank you
@mikeo9049
@mikeo9049 10 месяцев назад
If you don't mind me asking, what do you record your videos with? Keep up the great work.
@ApartmentMaintenancePro
@ApartmentMaintenancePro 10 месяцев назад
Most of the time its an iphone 14 pro. When I'm at home, I use a nikon z6ii with various lenses.
@cwilliams6884
@cwilliams6884 10 месяцев назад
if you can find the relay that goes on the board that's a pretty easy board fix
@adielguillermo
@adielguillermo 9 месяцев назад
How can bypass if is the heat?
@viper22304
@viper22304 3 месяца назад
thinking the same question.
@mohammadalizada7715
@mohammadalizada7715 4 месяца назад
You said that the board is bad so why still the natural works there? 🤔
@BigWilldeClue83
@BigWilldeClue83 2 месяца назад
Fan relay is bad on the board, so once it calls for as the relay is the only thing that doesn’t close to complete the circuit.
@5251168
@5251168 10 месяцев назад
In that application why not just use a spst 90290 or other rectangluar fan relay, the other circuits are not being utilized, and eliminates the thunk noise people will complain about
@ApartmentMaintenancePro
@ApartmentMaintenancePro 10 месяцев назад
I used what the building had, which was the relay that can bypass almost anything. I've also used 2 pole contactors in a pinch before for the same thing. It's in a common area in an apt building.
@abdullah_q8171
@abdullah_q8171 10 месяцев назад
Bypass you dont use the board?
@benjamintimmins1656
@benjamintimmins1656 10 месяцев назад
The relay on the board is stuck open...this is a better way than hooking the fan up to door switch where it runs all the time...
@esbonwordenjr6069
@esbonwordenjr6069 9 месяцев назад
Just take the heat wire off and put it on the eac terminal and bam your done till you get a new board because no one usually has an electric air cleaner hooked up so use that terminal.... it will just make the fan turn on immediately when a call for heat or cooling comes in.... just as long as you dont have an ecm motor but even if you did no relay would work anyway
@bobbywanger8123
@bobbywanger8123 10 месяцев назад
👍👍👍👍👍🔥🔥🔥🪛🪛🪛🪛🪛
@ApartmentMaintenance
@ApartmentMaintenance 10 месяцев назад
I keep one of those relays on hand for an emergency situation just like in your case. I put it in place of the goodman AWUF blower board if I dont have a board on hand for some reason. Its funny how some guys are amazed when they see something like this done cuz all they know is swap out part for part. But if you understand how the system & the relays work you can make it happen. Nice job bro! 🛠️👍
@ApartmentMaintenancePro
@ApartmentMaintenancePro 10 месяцев назад
Thanks man ! Hope all is well with you. I've used contactors before to bypass boards in a pinch 😆 there's always a way to make it work
@ApartmentMaintenance
@ApartmentMaintenance 10 месяцев назад
@@ApartmentMaintenancePro Sure is. All good with me. Waiting for the weather to cool off some to catch a break & get some other things done around the property. It's just been non stop all summer.
@jugears1081
@jugears1081 2 месяца назад
Thanks
Далее
How a Relay Works with the 90-340
11:02
Просмотров 85 тыс.
Troubleshooting Goodman Fan Control Blower Board
18:50
Сыграл на опережение #юмор
0:20