Chapter 19 - I wanted to make this video about the field charger power supply or remote power supply.
I show you the 7 most important parts of this power supply.
You can do a lot of things using the dip switches.
General Alarm, Split Alarm, Xplit Temporal and Selective Silence.
Hope you enjoy and like this video and most important that you learn somrthing new!
Stay safe and Have fun!!
Subscribe, Comment and leave a thumbs up!!....

Опубликовано:

 

3 сен 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 12   
@FireAlarm33
@FireAlarm33 2 года назад
Cool video! Love the updated intro.
@lumenfirealarms
@lumenfirealarms 2 года назад
Thanks for watching!! Yes I have new intro since the past video!! Stay safe and have fun!! ...
@ctalarms8338
@ctalarms8338 2 года назад
Cool new intro, this is a very detailed video and I love it!! Stay safe mate.
@lumenfirealarms
@lumenfirealarms 2 года назад
Hello my friend!! Thanks for watching!! Yes new intro!! I'm glad you liked the video!! Stay safe and have fun!! ...
@AsifAli-yb4hz
@AsifAli-yb4hz 2 года назад
Really nice video, Can you pls tell me, what is the difference between primary power supply & secondary power supply. If secondary power supply not available can I replace it with primary power supply as both gives 24v output. Also, while programming a ACPS, AC time delay on what basis I have to select either 2, 8 or 16
@lumenfirealarms
@lumenfirealarms 2 года назад
Hello thanks for watching! I have to say that will depend on your system design! Power supplies like AMPS-24 or ACPS would be consider with an NFS2-3030 and power supplies like FCPS-24 or PSE will be used to notification appliances or other supplementary applications! About the AC time delay I think it will depend on your standard's final suser! Stay safe and have fun!! ....
@FireAlert
@FireAlert 2 года назад
Nice, I wish they had a bigger aux output so you could power ANN-80s and COs like on my system without having to worry about pulling to much current
@lumenfirealarms
@lumenfirealarms 2 года назад
Cool device!! There are another power supplies! Thanks for watching! Have fun!! ...
@TheAirosari0921
@TheAirosari0921 2 года назад
Nice Video! Can I ask, If I have 10 speaker/strobe devices connected to this device how can I sync the voice evacuation from my main FACP?
@lumenfirealarms
@lumenfirealarms 2 года назад
Hello thanks for watching! The voice evacuation message comes out of the digital amplifier through the DAL of DVC if you wanna sync the strobes you need to assign the brand of the devices with the dip switches inside the cabinet of the power supply! Stay safe and have fun! ...
@TheAirosari0921
@TheAirosari0921 2 года назад
@@lumenfirealarms Thank you for your response. So i will run a new conduit to connect my speaker to main FACP amplifier?
@lumenfirealarms
@lumenfirealarms 2 года назад
Hello if you have your digital amplifier there yes. I hope this is only for a demo board you are putting together! Stay safe and have fun! ....