@wing4ever
@wing4ever Год назад
I have this exact furnace (2 years old), the symptoms were exactly the same as your video showed. I followed your process and guess what……a spider web in exactly the same place!! Just finished cleaning the main orifice and works like new. I’m retired with no extra $$ for service calls, so THANK YOU!!!!
@equake2011
@equake2011 11 дней назад
Man, I got to thank you cuz if I wouldn't have came across this video, I was about to call a technician. I was having the same issue and couldn't figure it out. But I did what u just did and now it's blowing hot. Thank u again for this video.
@PerryHopkins-o6h
@PerryHopkins-o6h 17 дней назад
Thanks for that video I had the exact same problem, fixed in 5 minutes
@hectorvalenzuela7632
@hectorvalenzuela7632 9 месяцев назад
Graxias por este video hoy aprendí algo nuevo en carrera de técnico 👨‍🔧
@mattalford3932
@mattalford3932 25 дней назад
Its crazy how those break like that
@rajkumard73
@rajkumard73 11 месяцев назад
Had same problem. Fixed it. Thank you very much.
@nymincho
@nymincho Год назад
Thank you ma man. Need it this winter.
@mattalford3932
@mattalford3932 25 дней назад
That literally happened to me when tightening one of those fasteners
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 Год назад
That sure was a terrible looking gas pipe/line situation. who the hell thought of that lol. Man that screw breaking would have pissed me off man. Gotta love when someone before you rheems the hell out of a screw.
@mattalford3932
@mattalford3932 25 дней назад
Mine isn't leaking with only 3 screws, but im definitely going to replace all 4 with better ones.
@elipasillas2509
@elipasillas2509 Год назад
Thanks for all your videos, they've been very helpful so far. I was hoping you could guide me in the right direction. I have this exact model of a furnace. The issue is that it will start up normal but after a few minutes gives me an ignition fail I've replaced the igniter, flame sensor and limit switch. But continue to get same problem. Originally it would work 80% of the time but every so often would give ignition fail reading. But now I can get it to work at all. I see it ignite go to blue flame but after a few minutes the fire stops and I'm just left with the fan pushing out cold air. The machine keeps giving me the one flash - ignition fail...
@Victoryhomeservices209
@Victoryhomeservices209 Год назад
Check your vent on the roof make sure it’s not blocked I would start with that if the vent is ok it could be your circuit board
@esquewingate2982
@esquewingate2982 11 месяцев назад
I have the same furnace and just installed it but haven't attached the roof jack because I see a circular plate inside the furnace exhaust housing is that supposed To be removed or is that a fire shield?
@yurizhivago4848
@yurizhivago4848 Год назад
Great video. I am a HVAC guy in Canada and we have no spider issues but I have heard that is for real in parts of the US. Why on earth do spiders find orifices attractive and how do they crawl all the way in there. Do they nest in other parts of the house and cause similar problems?
@Victoryhomeservices209
@Victoryhomeservices209 Год назад
No, I’ve only found them in the gas valve area. They come down through the flue pipe in the summer and lay eggs inside. I’ve had times where I’ve opened it up and a bunch of little baby spiders came out. Wish I would’ve got that on video that’s the only place I find them.
@yurizhivago4848
@yurizhivago4848 Год назад
@@Victoryhomeservices209 Down thru the flue pipe I would have never thought of that. I get lots of small sparrow birds doing that and ending up in ventor fans and the intake of the occasional high efficiency furnace nesting.
@Hvac-dude
@Hvac-dude 4 месяца назад
What causes these spiders to do this ?? What kind of spider is it
@Victoryhomeservices209
@Victoryhomeservices209 4 месяца назад
Yes spiders can cause that symptom not sure the type of spider
@drizzzzy12
@drizzzzy12 Год назад
I'm getting ignition failure code. Put new ignitor and flame sensor. Now the flame comes on I thought I was good. But the flame won't stay on. Please help
@maintenanceman1015
@maintenanceman1015 Год назад
Gas check leak at end 👍. If you had tried to remove the broke screw could had gotten worst ,maybe a 1/4 20 nut would have fit . Watched a few of your videos must me a local park maintenance man.
@Victoryhomeservices209
@Victoryhomeservices209 Год назад
No I’m an HVAC technician I work for a company in the Bay Area that services residential light commercial and mobile homes 👍 thanks for watching please subscribe if you haven’t already 👍
@Eliminater98
@Eliminater98 Год назад
I'm glad I found your video because the last person that I had come fix my furnace was just because of a spider like it was again and that guy charged me 100 just for that
@miladysbeautys
@miladysbeautys Год назад
Come fix my furnace please
@alross18058
@alross18058 Год назад
Still looked like gas pressure was a little low
@garyhenry2546
@garyhenry2546 Год назад
You didnot break that screw it wobbly when you first turned it the last guy but it back together like that
Далее
Только ЕМУ это удалось
01:00
Просмотров 2,5 млн
Ванька пошел!!!! 🥰
00:18
Просмотров 909 тыс.
Smart Meter Disaster!!
16:33
Просмотров 556 тыс.
Mobile Home Sealing Ductwork
16:02
Просмотров 43 тыс.
Why This Window Heat Pump Is Genius
13:24
Просмотров 1 млн
Coleman Mobile Home Furnaces OLD vs NEW?
10:50
Просмотров 184 тыс.
Bubble отель в Исландии 😍
0:47
Просмотров 1,6 млн