In this video I visit a tenant who’s air conditioning wasn’t working at all! #hvacguy #hvaclife #hvactrainingvideos #hvac #airconditioner #hvactechnician #hvactroubleshooting #furnace #heatpump #hvacinstall #condenser #condensermotor #skilledtrades #bluecollarpride
Merch Store : hvac-guy-2.creator-spring.com
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Makita Wet/Dry Vac: amzn.to/3VVHpsz
Veto OT-LC: amzn.to/3wSK1Nj
Appion AV760: amzn.to/3OkrwHC
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

28 май 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 94   
@Ogtonyg
@Ogtonyg 2 месяца назад
I wish every manufacturer would take note from Rheem as far as making the outside unit easy to take apart...
@MrMultitool
@MrMultitool 2 месяца назад
You got that right!
@Bob-cx4ze
@Bob-cx4ze Месяц назад
We get cottonwood by us and they need to be cleaned out every year. Twice a year would be idea. It blows my mind that they don't have a better way to take everything off to clean the coils.
@derek10w
@derek10w 2 месяца назад
Never apologize for taking the time to make sure power is off to the unit 👍
@neutrodyne
@neutrodyne 2 месяца назад
It wouldn't surprise me if you checked out the back side of the circuit board you would find the problem to be a bad solder connection at the fan relay.
@scotttiminey
@scotttiminey 2 месяца назад
Curtis gives me anxiety watching him work around all the invading vegetation instead of yanking it. I'd pull that crap out of my way before I did anything!
@TomLawson05
@TomLawson05 2 месяца назад
Great troubleshooting Curtis to get the air on thanks for the video
@jagfandaddy2878
@jagfandaddy2878 2 месяца назад
Curtis, you must always have a lawn company following you 🤣
@Cw2nh
@Cw2nh 2 месяца назад
These instructional videos are incredibly beneficial to me, as I am currently educating myself on the potential malfunctions of a central air system. These types of videos are very helpful, and I encourage you to continue producing this excellent content.
@HVACGUY
@HVACGUY 2 месяца назад
Glad you like them!
@DC-do8vd
@DC-do8vd 2 месяца назад
Hey Curtis. I have been in this trade for 20+ years and have always told my apprentices to not take short cuts and work safe. So I have to ask, why in the world would you not take two seconds to disconnect the low voltage before changing the board to prevent the possibility of getting shocked, blowing a fuse, or shorting the new board? I really enjoy your videos, but I believe that there are probably a number of apprentices that watch them as well to learn from you and that is definitely not setting a good example.
@JesseDoesHVAC
@JesseDoesHVAC 2 месяца назад
I was wondering the same thing.
@BigJeezie
@BigJeezie 2 месяца назад
I have a 2001 American Standard 2.5t package unit on a mobile home in Florida. It works perfectly but can struggle on 95+ days and run a lot. I’ve maintained it for the last 10+ years and my dad did before. I called to have a coil clean done and they wanted $1100! It’s a no remove clean. So I ordered the Nu-Calgon cleaner and spray nozzle. Just go back to doing it myself. I’ve already done caps as well. Preventative due to age. Oh and the last small ac guy I had over put a hard start kit in a few years ago. All the last techs in the past seven years told me to never replace it until it has a major failure. “They don’t make them like that anymore.”
@my-yt-inputs2580
@my-yt-inputs2580 2 месяца назад
You should probably keep a pair of pruning shears in your bag. ;) As much as I see you having to work around overgrowth.
@robalexander7348
@robalexander7348 2 месяца назад
Good job Curtis, you might have to start carrying a Whipper Snipper with you, to clean up around your work space 🤔 Au
@blackdogukulele
@blackdogukulele 2 месяца назад
excellent video keep up the good work. i love the detailed camera angles i learn so much!
@bigscout1584
@bigscout1584 2 месяца назад
I've always used a 5/16 or 1/4" socket for those clips and pushed it on them and they released
@duanehouston7689
@duanehouston7689 2 дня назад
Great idea to hold the disconnect against the wall when pulling switch. I remember pulling one off the wall that was poorly anchored.
@charlesmalinoski6325
@charlesmalinoski6325 2 месяца назад
The ink pen you mentioned,to remove the board from the clips. Is a clear barrel/Bic Ink Pen... Lol / It works tho ..
@grandinosour
@grandinosour 2 месяца назад
The same Bic pen commonly used to wind cassette tapes in the cassette tape era...perfect fit.
@jkmarshall3553
@jkmarshall3553 25 дней назад
@@grandinosour Oh, I 'know' that Bic pen. LOL!
@jimwhite9483
@jimwhite9483 Месяц назад
1/4 inch copper tube, deburred and slightly swaged, works very well for me to remove boards from the stand-off posts. Great video, Curtis.
@Dustin-zk8nb
@Dustin-zk8nb 2 месяца назад
Thanks for the knowledge these videos are real helpful
@softwarephil1709
@softwarephil1709 4 дня назад
Considering how cheap computer chips and displays are, I think they could display an error code rather than flashing lights.
@jthonn
@jthonn 2 месяца назад
Great advice, thanks Curtis
@HVACGUY
@HVACGUY 2 месяца назад
Any time!
@stephenbullock-yn3vh
@stephenbullock-yn3vh 2 месяца назад
Great job Curtis 👍
@HVACGUY
@HVACGUY 2 месяца назад
Thanks 👍
@DevinHVACInc
@DevinHVACInc 2 месяца назад
Well done. Troubleshooting on point
@ms7168
@ms7168 2 месяца назад
I used to give you the supply air temperature I had a thermometer that would measure it and that gives you a good idea of where things are I also used to monitor my indoor humidity if it went up it wasn't good. It's still Spring until June 20 and around here it doesn't really get hot until then. My folks used to always quip "Hot as the 4th of July" and "Cold as Christmas" .
@thesilentonevictor
@thesilentonevictor 2 месяца назад
Good clean job Curtis
@HVACGUY
@HVACGUY 2 месяца назад
Thanks 👍
@raykrv6a
@raykrv6a 2 месяца назад
Nice work. At least you weren't roasting in the sun working on the unit. You must have a ton of money tied up in replacement parts on your truck. How do you know what to carry around?
@kg4muc
@kg4muc 2 месяца назад
Great Job! That coil definitely forgot to take off its fur coat!
@HVACGUY
@HVACGUY 2 месяца назад
Thanks 👍
@stevencossaboon3237
@stevencossaboon3237 2 месяца назад
Nice work as usual Curtis
@chrisnapier5626
@chrisnapier5626 2 месяца назад
Good job,Curtis!
@HVACGUY
@HVACGUY 2 месяца назад
Thanks
@butlerstouchHVAC
@butlerstouchHVAC 2 месяца назад
great diagnosis 🔥
@romeoser5397
@romeoser5397 2 месяца назад
Before i left my previous company, i was doing startups, and always found that wire on the bottom of the contactor to be off, or loose, the company i worked for installed ruudd and tranes and i'll always see the bottom plate to be blugged down due to little amount of room under the contactor
@TxGuitarPlayer
@TxGuitarPlayer 2 месяца назад
Another good one
@HVACGUY
@HVACGUY 2 месяца назад
Thanks
@dkinfishing
@dkinfishing 2 месяца назад
Wish I could say the same here in Michigan Curtis…. Memorial Day was chilly and rainy and the following days has been chilly as well lol
@fernandobazan829
@fernandobazan829 2 месяца назад
I would rather have it chilly and rainy than 97 Degrees and 100% Humidity what you spend in winter we spend in summer in electric bills we’re switching to all electric? in USA NOW ? That’s crazy
@dkinfishing
@dkinfishing 2 месяца назад
@@fernandobazan829 at least that means guys are staying busy with work I’m sure with those temps
@mattbilodeau2433
@mattbilodeau2433 2 месяца назад
If you find that tool to push those pins in please make a video about it I am very interested in getting on too
@tommywwalden1599
@tommywwalden1599 2 месяца назад
The tool he refers too is the basic Bic Pen. You pull out the pen (pen tip with ink) and you are left with your PC Board removal tool. One of the vendors we used to service our UPS; their tech showed me this trick with a Bic pen. And not kidding, the company pens they gave away (Bic Pens) had printed on them company name, phone number and "PC Board Removal Tool".
@dilchproductions
@dilchproductions 2 месяца назад
I could tell by the sound of the fan that the coil was plugged!
@woodystokes1543
@woodystokes1543 2 месяца назад
Nice work as always 😊
@softwarephil1709
@softwarephil1709 2 месяца назад
Another excellent video. Thanks. 👍
@terryh8421
@terryh8421 2 месяца назад
No crispy critters!
@jeffadams9805
@jeffadams9805 2 месяца назад
Great work
@HVACGUY
@HVACGUY 2 месяца назад
Thanks
@mediadaemon
@mediadaemon 2 месяца назад
I bet as the fan terminal was coming loose from the contactor, it caused spikes in current that burned the contacts in the defrost boards fan relay.
@heatingairservices8708
@heatingairservices8708 2 месяца назад
Great Job .....Rheem dealer here all 27 yr in trade ...& just love then green Old Tanks & Now Esp the Newer Units ...easy access to pretty much all components
@bobboscarato1313
@bobboscarato1313 2 месяца назад
Multi-pronged plugs would be more effective for those boards! My opinion only.-
@wildmanwv
@wildmanwv 2 месяца назад
Does Ruud not put a crank case heater on their heatpump outdoor units?
@kens.3729
@kens.3729 2 месяца назад
Really Disappointing to See such a New Unit has a Faulty Control Board. 🤔👎
@bobboscarato1313
@bobboscarato1313 2 месяца назад
Power surge?
@kennymayo4578
@kennymayo4578 2 месяца назад
Could have been a critter or the vine growing by the circuit board, don't see many warranty calls with rheem
@harrydickson4575
@harrydickson4575 2 месяца назад
👍👍👍
@heatingairservices8708
@heatingairservices8708 2 месяца назад
how did you take board off ..trick i learnt over 27 yrs was a cheap bic ink pen ..pull the cartage & the writing ends works perfect to most time squeeze & pop the boards catches right loose
@jeffrey4184
@jeffrey4184 2 месяца назад
These people have trees growing in there condenser. lol
@hamedoa29
@hamedoa29 2 месяца назад
Can someone help me understand why didn't he check the defrost sensor? I'm not familiar with heat pumps so I'd appreciate it if someone explains why not check the defrost thermostat since that can also cause the fan to stop?
@masontull8388
@masontull8388 2 месяца назад
Because in a call for cooling the defrost temperature sensor doesn't come into play.. if it have power to the reversing valve it wouldn't be part of the circuit for the fan.
@hamedoa29
@hamedoa29 2 месяца назад
@@masontull8388 Thanks for the info 👍
@tedhicks5431
@tedhicks5431 2 месяца назад
Hey I cured my yellowjacket leak detector
@HVACGUY
@HVACGUY 2 месяца назад
😂
@tedhicks5431
@tedhicks5431 2 месяца назад
@@HVACGUY i stopped loning
@tedhicks5431
@tedhicks5431 2 месяца назад
Loaning it out
@garrettspivey
@garrettspivey 2 месяца назад
Poison oak growing out of the unit lol
@spot878
@spot878 2 месяца назад
Looks like the home owners would keep it cleaner around the unit ..
@dustinhensley2208
@dustinhensley2208 2 месяца назад
What mount do you use for your iPad ? Thanks !
@alvarolucio8264
@alvarolucio8264 2 месяца назад
Boa Noite todas as placas da unidade condensadora e da unidade evaporadora são padrões pra todas as marcas? Parabéns sou daqui do Brasil
@joeteves6288
@joeteves6288 2 месяца назад
Heatpump.
@reneespinosa3369
@reneespinosa3369 2 месяца назад
Why would it still shock you after you pulled the disconnect?
@bobboscarato1313
@bobboscarato1313 2 месяца назад
Over the years I've found disconnects that didn't work! Always check por power!
@Hvacnc
@Hvacnc 2 месяца назад
Had a pull out style where one metal prong was broken inside the disconnect. I Got shocked 😂
@bmsuter1533
@bmsuter1533 2 месяца назад
The low voltage power comes from the inside unit. 24 vac can surprise you if you're not expecting it.
@Hvacnc
@Hvacnc 2 месяца назад
@@bmsuter1533 especially if you sweating/wet
@softwarephil1709
@softwarephil1709 2 месяца назад
The Cybertruck auxiliary power for lights and accessories is 48v.
@jme36053
@jme36053 2 месяца назад
Does anyone do board repair? It seems a relay replacement would be more efficient than a complete board replacement.
@GoatzombieBubba
@GoatzombieBubba 2 месяца назад
You will be liable if it shorts and starts a fire that spreads to the house.
@bobboscarato1313
@bobboscarato1313 2 месяца назад
Those boards can break as easy as Matzo bread.- Laheim!
@mikemaki1104
@mikemaki1104 2 месяца назад
Tamia look dirty how come you didn't clean it
@mikehouser5430
@mikehouser5430 2 месяца назад
1st
@sir.cannabis1173
@sir.cannabis1173 2 месяца назад
Your an adult 👍🏻
@bobboscarato1313
@bobboscarato1313 2 месяца назад
First!
@mikehouser5430
@mikehouser5430 2 месяца назад
@@bobboscarato1313 🤣
@woodystokes1543
@woodystokes1543 2 месяца назад
All the room in the world and the control board is mounted behind the rail ?😊 engineering failure 😊
@kikemotors6138
@kikemotors6138 2 месяца назад
Couldn't he have dis one Ted the 24 bolts to the contacor and then the board can't shock you?
Далее
High Voltage On My Low Voltage!! #hvacguy #hvaclife
21:26
HVAC Is The Compressor Bad?
9:33
Просмотров 1,4 тыс.
Industrial Cooler Major Problems
22:53
Просмотров 13 тыс.
The Old Goodman AC has a FAKE Hard Start Capacitor
12:16
Odd Complaints Lead to Scary Find! #hvacguy #hvaclife
29:11