Тёмный

Cummins QSX15 Generators ECU ECM & sensors complete wiring explanation 

INFO Tech
Подписаться 5 тыс.
Просмотров 5 тыс.
50% 1

Опубликовано:

 

2 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 25   
@RitcheUntaran
@RitcheUntaran 6 месяцев назад
Nice video sir info tech, sir can you make a video how to connect example dse controller to ecm or ecu, thanks and take care always sir
@AshokKumarsingh-t5t
@AshokKumarsingh-t5t 26 дней назад
1250 kva DG ka control circuit diagram ka practical video banaaiye
@Info-Tech-
@Info-Tech- 2 месяца назад
Thanks friends
@winnaing6250
@winnaing6250 8 месяцев назад
Pls, let me know the Cummins Qsk 23 engine with dse 8610 wiring diagram
@rshid-vq3lb
@rshid-vq3lb 9 месяцев назад
Dear Sir, I have some problem to fuel shutoff valve. I was Check shutoff valve found resistance 8.2 ohms. But shutoff valve no work when engine running (run within 02 sec. & off gen-set). I manually supply 12 v dc to shutoff valve , then engine start & run Gen set no stop. Please good advise send to me. Rds. harun
@Info-Tech-
@Info-Tech- 9 месяцев назад
First Which type of solenoid ? 3 wire or 2 wire
@Info-Tech-
@Info-Tech- 9 месяцев назад
Check first all warning ⚠️ alarm Make sure you don't have any warning alarm, if you have so warning first fix it about problem, then rest all alarm and try again
@rshid-vq3lb
@rshid-vq3lb 9 месяцев назад
@@Info-Tech- Thanks sir. one wire shutoff valve. QSX15 cummins engine.
@Info-Tech-
@Info-Tech- 9 месяцев назад
Check battery charging systems make sure alternator is working Battery conditions ok If these things are good the replace the shut off valve and try again
@rshid-vq3lb
@rshid-vq3lb 9 месяцев назад
@@Info-Tech- Thanks. First Gen set start & within 2 second stop gen set. Error 254.
@oiioii5386
@oiioii5386 8 месяцев назад
Sorry sir, previously I had a problem with the ECU ECM on the Cummins QSX15 generator with a problem with the HZ (frequency) not wanting to be adjusted, and the frequency was only stable at 50 Herzt, what should I do to solve this problem? Please help sir
@Info-Tech-
@Info-Tech- 8 месяцев назад
Qsx15 frequency is adjusting by software only
@oduduhenry70
@oduduhenry70 Год назад
Thank you very much. That was really helpful
@علاءالشمري-و8ب
@علاءالشمري-و8ب Год назад
Can you send me a catalog please.
@Info-Tech-
@Info-Tech- Год назад
Yes
@Info-Tech-
@Info-Tech- Год назад
Email me I send you abdurraheemk622@gmail.com
@khawarshahzad3927
@khawarshahzad3927 Год назад
Hi brother Same Gsc ESM generator not taking self . Starter relay not working...what is the issue
@Info-Tech-
@Info-Tech- Год назад
First check the ECM relay! When the ECM relay is faulty that means ecm is not turning on. When the ecm is not turning on, ecm not sending starting signal to the starter relay,
@khawarshahzad3927
@khawarshahzad3927 Год назад
@@Info-Tech- thanks issue resolved relay not sending signal to ECM relay base was faulty
Далее
🎙Пою РЕТРО Песни💃
3:05:57
Просмотров 1,3 млн
TROUBLESHOOTING THE GOVERNOR OF A DIESEL GENERATOR
10:25
How to Install Dicktator ECU - Wiring & Sensors Guide
26:15
How ECU/ECM works basics testing and fixing
12:14
How To Diagnose A Faulty ECU With No Communication
6:50
ECU data fail how to troubleshoot it benzblogs
15:59