EICR Remedial Work/Fuseboard Upgrade - Electrician in London Vlog #11 

Eastway Electrical
Подписаться 37 тыс.
Просмотров 21 тыс.
50% 1

In this weeks episode we carry out the remedial work following an EICR we carried out for a customers whose property is in North London.
The electrical installation condition report we carried out flagged up a number of issues including earthing matters, non-complaint power points and lights. The major job however was replacing the old dual tariff consumer unit with MCBs for a newer version with RCBOs.
The episode starts with us replacing an old shaver point and bathroom light fitting. We then move on to solve the issue with earthing on the metal class 1 light fitting. After a bit of fault finding we able to establish the cause of the earth fault and rectify it.
On the second day we remove the old and install a new fuseboard. Enjoy!
Follow us on social media:
/ eastwayelectrical
/ eastwayelectrical

Опубликовано:

 

30 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 69   
@alfredlawrence3182
@alfredlawrence3182 5 лет назад
Delroy and son are highly experienced and confidence inspiring tradesmen, not like some smart asses that post on here. Keep em coming Del and Son.
@williamrefurbish6416
@williamrefurbish6416 6 лет назад
new viewer appreciate the relaxed way you deal with work life, thanks for sharing
@thepowerisinyou2886
@thepowerisinyou2886 4 года назад
I like when you said take your time do the job right and don't rush. There are too many psychopaths running businesses rushing and bullying others. Life is too short to be wasting it cos of unnecessary stress and pressure. Cheers.
@kanshelmyles-lopez6359
@kanshelmyles-lopez6359 5 лет назад
Dont k know much,but looks great..I'm in school now learning this trade...I just started watching u..also another electrician from London..I'm from NY..but hoping one day to make it over there...
@DaddyBear3000
@DaddyBear3000 6 лет назад
I like the bit where you skipped having to make the hole in the ceiling larger to stuff the connectors through 😜 Never pretty is it. Typical turn of the century property where a lot of cowboys and DIY hands have had a go.
@seandempsey9396
@seandempsey9396 4 года назад
Hi Gary can you please tell me how this is done using the kewtech kt62 multifunction tester or the ROBIN kts 1620 MFT as the instruction book says nothing about the two lead high loop test, on the control dial there are two settings, loop 20 ohms 200 ohms and 2000 ohms, psc 200A 2000A and 20ka also how to do Ze Another great video thank you
@torontogta1639
@torontogta1639 4 года назад
looks the resident's electrical is much safe in Canada than UK, Our electricity 110V /240V.
@azizahmedmuhammad4124
@azizahmedmuhammad4124 4 года назад
You are amazing personality and sense of humour. I appreciate your works, courage and way of working. I am a beginner in electrician works. Hope we will get much information watching your videos. Just need more information when you use a particular tool or equipment e.g. multimeter or a Driver .
@kirtybearoriginal
@kirtybearoriginal 5 лет назад
What voltage do you bring into residential homes in the UK? Was that 240v to the fixtures and devices? Love the vids by the way. Just cool to see how things are done in other part of the world. From your vids so far i confirmed blue is neutral. In Canada its white
@PlymouthSparky
@PlymouthSparky 6 лет назад
Another informative vid Delroy. Keeping Marlene safe, very important
@eastwayelectrical
@eastwayelectrical 6 лет назад
Haha good old Marlene, lovely customer. Thanks for the comment PS
@hamidbazmi7948
@hamidbazmi7948 3 года назад
1 certificate or 2? 1 landlord certificate and 1 for changing the CU? Thanks
@craigpatterson4269
@craigpatterson4269 6 лет назад
nice one Del, I use bushes when doing smaller dbs like that with double lock rings to stand it off the trunking slightly to allow a gap for the lid, but prefer to use paxolin when doing bigger stuff to give myself lots of room for the cables to enter :-) great vids keep an em up pal.
@hamidbazmi7948
@hamidbazmi7948 3 года назад
Hi, I wonder if you issued 2) and 1 for EIC(changing the CU)?
@NoRetreatNoSurrender86
@NoRetreatNoSurrender86 6 лет назад
Thank jesus RCBOs i never install those shitty dual rcd boards
@mllinas3229
@mllinas3229 6 лет назад
Great videos Delroy 👊 Would you be able to talk about prices & more fault finding ;) Thanks
@johnhighland2260
@johnhighland2260 5 лет назад
Is the fan over the bath in zone 1 low voltage.over a unfixed shower head or is that ok in the UK
@alvinashman6371
@alvinashman6371 6 лет назад
Is your boy still training, how much longer does he have before he gets his ticket?
@neilvincent9530
@neilvincent9530 2 года назад
Nice video pity you didn’t let us see the end result instead of having a side on view
@markandsuriyonphanasonkath8768
@markandsuriyonphanasonkath8768 3 года назад
Delroy, love your videos - many thanks - and Hi from Phuket Thailand. You are SO CORRECT "haste makes waste". Looking forward to more videos - love "your style"!
@tonydavison3312
@tonydavison3312 6 лет назад
Nice work Delroy, great Vlog's keep them coming.
@eastwayelectrical
@eastwayelectrical 6 лет назад
Thanks Tony, thats very kind of you to say.
@zippymo672
@zippymo672 6 лет назад
Hi Delroy, if I see you around in Leyton, I will come and say hello. I love your vids. I'm starting a city and guilds electrical level 2 in September.
@eastwayelectrical
@eastwayelectrical 6 лет назад
Thanks Zippy. All the best
@barryturner1146
@barryturner1146 3 года назад
Great job again delroy
@philipwaters9190
@philipwaters9190 4 года назад
Great stuff Delroy.I've watching your videos.We use various types of arc fault breaker here in the US. I see the UK recently started to install them . Maybe you could share a video when you install and test onPhil form Dublin living in the US . Been a sparks for 42 years. Cheers mate?
@janesouth2943
@janesouth2943 6 лет назад
Nice new fuse board even expensive rcbos but very old wiring
@peteryoung9608
@peteryoung9608 6 лет назад
Which the fuse board is designed to protect !! Pete 78 a very old electrician.
@paultabor2446
@paultabor2446 4 года назад
What method of joining cables did you use WAGOS or crimps
@hbarnes2489
@hbarnes2489 6 лет назад
although I knew alot of what you talked about on this video its still go to see how someone else deals with it
@eastwayelectrical
@eastwayelectrical 6 лет назад
Glad you found it of use. Thanks for the comment
@albertsteptoe3710
@albertsteptoe3710 5 лет назад
Delroy The Spark I’m thinking of the best way to incorporate an economy 7 circuit board into one main board along with the rest of the house . Now I’ve seen this gives me a little bit good for thought cheers bud . I was originally thinking a Hagar stack and use the bottom for the economy 7 but this looks a better way rather than a big horrible looking board for only 4 storage heaters . 👍 any tips be welcome cheers bud
@ralph17p
@ralph17p 5 лет назад
I just installed a Hager board with a bunch of their compact RCBOs. They do make it a doddle to install, with all that extra space.
@michaelboyes4948
@michaelboyes4948 6 лет назад
You should get yourself the 221 series of wagos instead of them 222 you've used
@eastwayelectrical
@eastwayelectrical 6 лет назад
Thanks for the comment Michael
@MrFreddywise1
@MrFreddywise1 5 лет назад
realising you are limited for time between jobs would be good when replacing fuse board if 1 time you could take more time an show closer viewing of what your doing,.. other wise good work as always,
@yensabi
@yensabi 6 лет назад
Hi Delroy , I really enjoy your videos and the relaxed way you do your work , cheers...👍
@eastwayelectrical
@eastwayelectrical 6 лет назад
Thank you Yensabi. Really appreciate the kind words
@petereyre5188
@petereyre5188 5 лет назад
New to your channel, great stuff in such a wonderful relaxed style 👍👍
@rickybee4537
@rickybee4537 5 лет назад
Wago the life saver. Selco does a similar cheaper brand now as well.
@muhammedrob6823
@muhammedrob6823 5 лет назад
Hi new to the trade just wondering in some places the cables dont have there sheath so how would you know which live earth neutral are the same circuit.
@Clydepatos2001
@Clydepatos2001 5 лет назад
Did you crimp the short cable mate?
@maliklindo10
@maliklindo10 6 лет назад
What's that slim line screwdriver you use
@Thang_MD
@Thang_MD 4 года назад
i enjoyed
@carlmarquardt994
@carlmarquardt994 6 лет назад
Great to see u take pride in your quality workmanship Del.
@niallers8572
@niallers8572 6 лет назад
have you ever not been paid for doing work
@malcolmcroll
@malcolmcroll 4 года назад
need more sound Del -
@leeguitarmcr
@leeguitarmcr 4 года назад
Hi, I have just found your videos recently and I find them to be a great help in my new chosen career. I am yet to gain qualifications but I have one question: When you tested the earth & phase you used a megger tester but when you tested the same later on, you used your fluke tester. Is there a massive difference between the two testers? I was just curious to know why two different testers were used in the video. Great videos, many thanks for sharing your knowledge. All the best - Lee
@AskCorie
@AskCorie 4 года назад
You can use the megger as well as the fluke voltage tester to prove continuity. Remember the megger is multitester meaning it has more than one use/purpose.
@leeguitarmcr
@leeguitarmcr 4 года назад
@@AskCorie Many thanks for your response. Much appreciated!
@tomala57
@tomala57 6 лет назад
I like the new intro in your videos. I agree on rushing, nothing good comes out of it. Continuous honest work at normal pace is the right way to do the job.
@eastwayelectrical
@eastwayelectrical 6 лет назад
Thanks for the comment
@tomdavis8820
@tomdavis8820 5 лет назад
New sub but love the vids and info 👌
@jak50cent
@jak50cent 5 лет назад
Do you guys use cordless drills
@brianoceallaigh8714
@brianoceallaigh8714 6 лет назад
Good video Del... Just curious to what screwdrivers you use rearly ever see you use a pozi bit drill to drive home the woodscrews!! Lost my favourite terminal screwdriver a while back had it a very long time but replaced it with a Stanley Fatmax that I picked up in Woodies one day and oddly enough find it every bit as good... Keep the Vlogs coming...
@jak50cent
@jak50cent 5 лет назад
Your a smart sparky
@stevebrindley
@stevebrindley 6 лет назад
Love the cheesy (porno) type short clip at the start 😂 another great video ! Keep up the good work
@phillwildman
@phillwildman 6 лет назад
Love the videos Delroy.
@landy9020
@landy9020 6 лет назад
A good earth you mean continuity of cpc
@stevencorbin103
@stevencorbin103 6 лет назад
Good vid mate ... screwdriver torque on those mcbs.... 😀😃🤣
@32079rme
@32079rme 6 лет назад
in England you don't have junction boxes for light fixtures?
@eltonsakos3662
@eltonsakos3662 5 лет назад
Hi Del Why did you use those mini rcbo and not standard split rcd board ?you mention storage heaters ,pls explain a bit more ,thanks
@MrFreddywise1
@MrFreddywise1 5 лет назад
point of view but why was the fuse box placed so high up.....
@sparksparky9592
@sparksparky9592 6 лет назад
Excellent video. Didn't you update the tails to 25mm and bonding to 16mm.
@britannic2000
@britannic2000 6 лет назад
Spark Sparky hi sparky when you update your tails do you do the service head side as well or just the cu side
@SME_Ste
@SME_Ste 6 лет назад
Since when did having 220v between line and cpc tell you had a good earth
@kamuts7
@kamuts7 6 лет назад
Also impedance test is a resistance i think?
@p00pipe
@p00pipe 5 лет назад
The 117 V readings between line and cpc, and neutral and cpc is a sign that the cpc isn't connected to anything and is just floating. Two parallel conductors separated by insulation forms a capacitor. If the cpc is just floating, then you effectively have two capacitors in series - one between the line and cpc and one between the cpc and neutral. You are just measuring the voltage at the centre point of the two capacitors, which will be half the supply voltage. But telling a customer they now have a good earth is a lot more reassuring.
@ass90
@ass90 5 лет назад
Them miniature rcbo$ are great!
Далее
荧光棒的最佳玩法UP+#short #angel #clown
00:18
МАЛОЙ ГАИШНИК
00:35
Просмотров 225 тыс.
Electrician chases thin walls
35:16
Просмотров 1,3 тыс.
I Don't Like How The Previous Electrician Did This...
21:42
Electrical Fault Finding Job
21:16
Просмотров 26 тыс.
Mining Magnetite
16:20
Просмотров 361 тыс.
Initial Verification - Testing someone else's crap work
32:55
Botchery, line tracing & core drilling
21:39
Просмотров 79 тыс.