Electrical Conduit vs. Cable: Which is best for your project? 

Practical Home Projects
Подписаться 2,6 тыс.
Просмотров 40 тыс.
50% 1

When planning out your electrical project, you have some flexibility to use either cable or conduit while still following the local electrical code. We’ll compare standard Non-Metallic Sheathed cable to UF-B type cable. We’ll go through flexible and rigid conduit for your indoor or outdoor needs.
As always stay safe and refer to your local code authority with questions.

Хобби

Опубликовано:

 

22 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@karenderuyter2568
@karenderuyter2568 Год назад
Thank you for clearing that up for me.
@practicalhomeprojects
@practicalhomeprojects Год назад
Glad it helped!
@Ricko1962
@Ricko1962 Год назад
Great video, thanks!
@practicalhomeprojects
@practicalhomeprojects Год назад
Glad you liked it!
@vince6829
@vince6829 Год назад
Thanks for sharing
@danmoore1088
@danmoore1088 Год назад
Really helpful, thanks!
@practicalhomeprojects
@practicalhomeprojects Год назад
Glad it was helpful!
@danhdo8233
@danhdo8233 9 месяцев назад
I've been watching ev charger or nema 14-50 for tesla charger video installing and couldn't find any video explaining in details like yours. Especially the Non Metallic Liquid Tight Flexible Conduit. I am planning running it from electric panel down to crawlspace (20ft) then outside for another 50 ft using this type of conduit. Then bury the gray PVC schedule 40 for burying 18" under the ground. Now I know NMLFC an be buried like a pvc. Learned something!
@OthmanAlikhan
@OthmanAlikhan Год назад
Thanks for the video =)
@practicalhomeprojects
@practicalhomeprojects Год назад
You are welcome!
@aaronho673
@aaronho673 Год назад
Very helpful!
@practicalhomeprojects
@practicalhomeprojects Год назад
Glad it was helpful!
@karimiHSE
@karimiHSE 10 месяцев назад
Very good 😮😮😮
@MrRicker9
@MrRicker9 Год назад
Some good info here, but......per the NEC you CAN NOT use THHN wire in an outdoor/underground application. It is rated for dry use only. Underground in conduit is considered by the NEC as a damp/wet location. This requires THWN rated wire. Typically you can buy dual rated THHN/THWN-2 wire.
@practicalhomeprojects
@practicalhomeprojects Год назад
Hi there. You are correct that the wire needs to have the "W" to be used in outdoor settings. I labelled it as "THHN/THWN-2" at 1:12, but I tend to just refer to it as THHN since almost all of the THHN wires on the market today are dual rated. Thanks!
@johndavies2949
@johndavies2949 8 месяцев назад
It always comes that way. Thhn/Thwn
@usmarinekenny
@usmarinekenny 6 месяцев назад
Just a correction, if it is rigid metal galvanized conduit it has to be buried 6” below grade and that’s to the top of the conduit not the bottom as that confuses people. And pvc is generally 18” to the top of the conduit with the exception of if it’s 120 volts circuit and gfci protected before it comes outside and goes into the ground can be buried at 12”. Now with that said using the flexible conduit buried in the ground is kind of a gamble as the whole subject to physical damage thing comes into play which is why they require even rigid pvc to be schedule 80 thick wall pvc when exiting the ground up to 8’ and down into the ground 18” if I’m not mistaken. It all depends on the inspector and if he interprets it to be in a physically damaging area. To avoid hitting it and breaking through it with like weed eaters and lawn mowers specifically the weed eater with the metal blade instead of the string, but just a safety thing. Just throwing some info at you. But I like your videos. Keep up the good work.
@practicalhomeprojects
@practicalhomeprojects 6 месяцев назад
Thank you for the insight. The "Subject to Physical Damage" piece is a bit subjective, so it's a great idea to speak with your local inspector. Ours told us that for a residential property we'd be fine with schedule 40 as long as it wasn't next to the driveway.
@candlemedia
@candlemedia Год назад
Veryyyyy informative. Thank you. If one wanted too, can they use the flexible pipe from the outside of a house that runs 50ft straight & buried 18" in ground and out to a supposed outlet which has romex 12gague running thru it? You've mentioned not running romex in the flex pipe but running single THHN wire, but why can the romex yellow jacket (hot, neutral and ground) run?
@practicalhomeprojects
@practicalhomeprojects Год назад
Hey there. You could run the romex inside, then switch to THHN inside conduit at a junction box. It's not completely forbidden to use romex in a conduit, but there are two issues: With 3 or more conductors, the total fill inside the conduit cannot be more than 40%. The romex has a much higher cross sectional area than the individual cables inside, so you'd have to oversize the conduit significantly. The second issue is that the pvc jacket around romex is actually a bit tacky and will have a lot of friction when pulling through a conduit; it's not very durable either so it may tear. The THHN cables are a slick nylon material. Hope this helps!
@neilconstantino309
@neilconstantino309 8 дней назад
Great video, man! I wanna install a 30amp power inlet for a generator to power my house after a power outage. I’ll probably use 50-60 feet of wire that runs from the back of my house to the front (where main panel is located). Given the scenario I’ve mentioned, what type (brand?) and gauge wire and what type of conduit should I use? Or if you could give me a full list of what I’ll need that’d be great😅
@practicalhomeprojects
@practicalhomeprojects 7 дней назад
I think this article will answer most of your questions. practicalhomeprojects.com/?p=138 The brand of your wires/conduit isn't important as long as they are UL rated for the application. Since it is outside, everything needs to be rated for wet areas.
@jimsummers487
@jimsummers487 8 месяцев назад
Electricians manage heat so that you have a cool running electrical system….fire code requirements are minimum standards…… A majority of you will need fire extinguishers
Далее
How to bend and install electrical conduit
20:14
Просмотров 1,3 млн
2DROTS vs WYLSACOM! КУБОК ФИФЕРОВ 1 ТУР
07:25
Should You Be ONLY Using 12/2? When Can You Use 14/2?
9:27
Practical Electrical Wiring-MC to Emt Connectors
11:43
Просмотров 371 тыс.
Electrical Conduit: Types and Uses
4:57
Просмотров 284 тыс.
How To Extend an Electrical Outlet
6:42
Просмотров 651 тыс.