Electrical Meter Base and Service Mast Install 

SRP Channel
Подписаться 1,1 тыс.
Просмотров 284 тыс.
50% 1

The main purpose of this video is to help electricians line up a service mast and make a straight roof penetration. Only licensed electricians should be doing this.

Опубликовано:

 

22 мар 2016

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 116   
@RJArens
@RJArens 11 месяцев назад
I learned the hard way on my install. I bought the exact same box for my install. Got everything nice and neat and failed inspection because my box didn't have a lever bypass which unbeknownst to me has been mandatory on new installs for about a year and a half now. Lesson learned. Check your codes.
@srpchannel0169
@srpchannel0169 8 лет назад
This video was meant to help Electricians with residential mast roof penetration and flashing installation. It also covers panel and meter base layout.
@jgongora16
@jgongora16 2 года назад
Hello, may I know what kind of weatherproof anchorage did you use to attach the meter box and panel to that brick wall? Thanks
@frankie2234
@frankie2234 5 лет назад
You explained it well. Video cut off before you finished.
@annetthill8107
@annetthill8107 5 лет назад
I was disappointed not to speak to a person but to have to listen to a long computerized message, BUT we were pleasantly surprised to have a tech notion at our door in 15 minutes who fixed our problem for us . Great service. I think if you could add a person to your phone protocol, it would be good for public relations.
@lakestatebullies7391
@lakestatebullies7391 3 года назад
Use metal roof gasket screws for the roof boot
@portaadonai
@portaadonai 6 лет назад
Do you avoid using an offset, and deep strut to avoid the wood trim because of looks? I like the whole house surge protector, what reasons do you use it for? Besides the obvious surges of power? I also like the electrical sealant, do you use that on plaster exterior walls too? We use caulking 7:44 We are required to use bonding bushings on all conduit that contains service conductors, like on the nipple, here in San Diego
@AndreaSchott-hw1ms
@AndreaSchott-hw1ms 5 лет назад
Absolutely stunning selection of modern fixtures on display. We needed something a bit more classic, which we were also able to find in the showroom, but even if we hadn't, the staff were super friendly and helpful, with a positively overwhelming library of catalogs filled with other options. I'm confident anyone can find the lighting solution they need here.
@LuisMorales-my5nj
@LuisMorales-my5nj 2 года назад
Will ONCOR allow you to use a meter socket and main panel unit or do they require it to be separate? I have the same old meter base on my home but I wanted to save space on the wall and only place the combo unit instead of a separate meter base and outdoor panel.
@marcodeluca4068
@marcodeluca4068 4 года назад
Hi great video, in a home that is in its 1950's the service is coming underground but the service is panel box is100amp would the service to street accommodate 200amp typically the power company says yes how can I tell?
@robwilliams4550
@robwilliams4550 4 года назад
We do it a lot different in Chicago, but still enjoyed watching it.
@carloslaban1013
@carloslaban1013 5 лет назад
Nice one. Thanks.
@wudemi8031
@wudemi8031 4 года назад
Thank you for the video, meter box looking like good quality.
@lauribricker9439
@lauribricker9439 6 лет назад
Was the old meter rated at 60 amp?
@kimberwolvert562
@kimberwolvert562 4 года назад
So the old main panel is now a sub panel ? If so do the grounds and nuetrals need to be separated in the old main?
@johntrauger68
@johntrauger68 3 года назад
Whichever becomes the sub must be separated.
@victormendoza6306
@victormendoza6306 3 года назад
Good job and clearly explanation, question what types of wire have to be from the meter to street electric post?
@torodaman
@torodaman 3 года назад
That looked like 4/0 aluminum, he could have gone 3/0 for the neutral to save a little money tho and #8 for the grounding bonding wire but armored ground wire, hope he didn't forget to bond on the gas and water pipes.
@bigguyprepper
@bigguyprepper 2 года назад
@@torodaman can’t bond gas pipes here, the AHJ won’t allow it. It’s also won’t let you in the code anymore
@RafaelSilva-qu4hh
@RafaelSilva-qu4hh 3 года назад
When it costs to assemble this one in the USA
@willcamp6319
@willcamp6319 Год назад
I would use rigid conduit going through the roof because it is stronger than emt
@srpchannel0169
@srpchannel0169 Год назад
Yes you are right. I am using 2in rigid.
@abcdef-kx2qt
@abcdef-kx2qt 5 лет назад
all the companies want worker as trainer , estimators , pr ject manager , supervisor, all in one and for a measly piddly 20 usd
@williamtreat5893
@williamtreat5893 2 года назад
Do you know the hex size for the wire lugs
@salvadorgutierrez4474
@salvadorgutierrez4474 3 года назад
Is there a part 2 ro this video?
@gazd4812
@gazd4812 3 года назад
does anyone know if its allowed to connect two "main panels" to the meter? i mean to connect two sets of wires to the bottom meter connection and each set to go to 2 different panels. (i want to work on my days off on a new panel, upgrading and adding circuits, while my old panel still works and still have electricity in the house).
@Nick-bh1fy
@Nick-bh1fy 3 года назад
I believe it is possible but not very common, it depends on the current service at your house ( how many amps ) and you need a meter that’s rated for 2 cables, also proximity to each other is important
@flynndog
@flynndog 5 лет назад
too many gaps on the roofing part of the video
@johnsmith-sw7ii
@johnsmith-sw7ii 6 лет назад
What type wire was used in the tower??? THHN/ THWN-2 or what????
@IceCreamJones42069
@IceCreamJones42069 5 лет назад
john smith URD or XHHW or XLP probably.
@bradleyhazekamp9689
@bradleyhazekamp9689 6 лет назад
SO weird to see a panel outside, did you end up locking the panel ?
@lazlenoir9364
@lazlenoir9364 6 лет назад
Bradley Hazekamp what country does a panel go outside please tell me somthing
@charljustinereyno1418
@charljustinereyno1418 6 лет назад
I think it's for maintenance purpose. To disconnect the power supply easily without getting into the house to shut off the breaker and then turn it on once the electric works is done
@Kite101dotcom
@Kite101dotcom 6 лет назад
Any townships that just have a volunteer fire department require a service panel outside in case of fire so they can cut off power easily and quickly in an emergency
@jeffreyspence7717
@jeffreyspence7717 6 лет назад
All they have to do is pull the meter like I do.
@HighestRank
@HighestRank 5 лет назад
Jeffrey Spence except areas with volunteer firefighters might be rural and /or high crime and their meter box might be one that’s hardened against theft, and a lot more difficult to just pull.
@bensonelectricinc
@bensonelectricinc 5 лет назад
This is an incorrect installation. You cannot have a hole in the panel that is above the bus bars without using a weatherproof fitting such as a Meirs hub. without this fitting or a weather proof fitting water can get into the panel and mess with the bus bars.
@erikwalls8048
@erikwalls8048 4 года назад
bensonelectricinc if the hole is below the bus bars the fitting doesn’t have to be water tight?
@chasefouse684
@chasefouse684 4 года назад
@@erikwalls8048 Nope. Some electricians will even drill a tiny hole in the bottom of the panel so that any water that somehow makes its way in can drain out
@dominicalphamale6293
@dominicalphamale6293 4 года назад
The EMT 2 inch conduit connectors were also not rain tight fittings. The connectors that he used were for interior applications
@derekstratford7937
@derekstratford7937 4 года назад
If you use a sealing lock ring yes you can
@DixonMasterElectric
@DixonMasterElectric 4 года назад
Wrong the hole above the panel is blanked off with a hub blank that comes with the panel also the 2 inch fittings are steel raintight fittings for outdoors so no problem there either anything else i can correct you guys on?
@ACommenterOnYouTube
@ACommenterOnYouTube 5 лет назад
why is the N not separated when you pull the power meter off..?? Why does it only separate the 2 HOT legs..??
@Nick-bh1fy
@Nick-bh1fy 3 года назад
Because the neutral isn’t live if the the 2 phases are pulled
@dickcheesewiz
@dickcheesewiz 4 года назад
If thats a 200 amp service the ground should be #4 bare copper. Also you when tigher in the connections a drip loop is needed.
@HobbiesandAdventures
@HobbiesandAdventures 4 года назад
Sexy installation lmao good stuff I’m like 4 months to go for my electrical course
@user-ln7of9gs4s
@user-ln7of9gs4s 2 года назад
Why put the panel outside?
@ricardoviana5059
@ricardoviana5059 2 года назад
Why you didn't install a disconnect box ?
@EvendimataE
@EvendimataE 6 лет назад
how many wires can go in the 2in conduit?
@HighestRank
@HighestRank 5 лет назад
EvendimataE a standard masthead only has 3 grommets.
@johnkulpowich5260
@johnkulpowich5260 4 года назад
Depends on how big your cable puller is
@johntrauger68
@johntrauger68 3 года назад
Depends on wire size.
@williamstanton6710
@williamstanton6710 5 лет назад
Shouldn't the #6 grounding wire and grounding rods be buried? Also I thought you need to take the #6 to the meter base?
@johnkulpowich5260
@johnkulpowich5260 4 года назад
Power companies have different rules connecticut nothing goes in the meter box
@johnkulpowich5260
@johnkulpowich5260 4 года назад
Cheap with white tape on neutral wires. Our power company wants two and half inch conduit for mast
@davidjacobs8558
@davidjacobs8558 5 лет назад
why use separate meter box and breaker panel box ? all in one box looks much cleaner and nicer.
@senorjalapeno3937
@senorjalapeno3937 4 года назад
So the meter can in the main panel would look cleaner compared to a separated assembly?
@benjamintorres9211
@benjamintorres9211 2 года назад
@@senorjalapeno3937 lmfao forreal like how 😂😂
@turtlesmo9603
@turtlesmo9603 2 года назад
108,000 jewels per phase👌🏾
@lauribricker9439
@lauribricker9439 6 лет назад
I've never seen an electric meter base positioned like that. Meters are usually at the back of the house or in the basement. The house where I grew up in had the electric meter and gas meter in the basement. The meter reader needed to be let in the house, that's why you would hear him yell "gas man". The meter reader would yell, "gas man" and the dogs would bark. Gas Man! Ruff, ruff, ruff!
@dyoel182
@dyoel182 5 лет назад
A lot of new construction (here in Texas at least) does an outdoor panel from the start. My indoor panel is grandfathered in but they told me when I bought the house that any major panel work in the future would move it outside.
@kiwiswat
@kiwiswat 4 года назад
Most places electrical readers have to come on property to read hence it cannot be installed inside or in a fenced area with a gate. Xcel Energy for example requires an installation in an accessible area
@bobsagetpiss
@bobsagetpiss 6 лет назад
Great electrical work the flashing work is another story its going to leak.
@AccordBass12
@AccordBass12 6 лет назад
Its always a good ideal to put your ground wire in 1/2 Pvc pipe incase it ever became electrified.
@steventrott8714
@steventrott8714 Год назад
If it’s got juice, the metal conduit does too!
@handymanbrian8269
@handymanbrian8269 5 лет назад
darn...i wanted to see you tie in the entrance wires
@IceCreamJones42069
@IceCreamJones42069 5 лет назад
Handyman Brian moving that service drop would be dangerous as hell and it probably weights 100 lbs.
@03Babyboomboom
@03Babyboomboom 5 лет назад
will power company furnish meter box anyone know?
@IceCreamJones42069
@IceCreamJones42069 5 лет назад
michael patrick they’re available at any local supply house or Home Depot or Lowe’s.
@drewt3210
@drewt3210 4 года назад
Here in NC we have to install the meter base, get it inspected/permitted by the County, then call Duke Energy to connect power. Power company does not supply anything except the meter itself.
@senorjalapeno3937
@senorjalapeno3937 4 года назад
Why.. just why didn't you place the meter at 5ft center to the can, then come from the right side knockout with an offset, and run the leads from the bottom left corner of the main panel? Run your leads fixed to the bottom of the panel to the side and make connections from the top? Just why? Also, why did you even bother with the can if your placing it 11/2-2ft from the existing old meter???? Why?? Its still high..but okay
@wiregirl
@wiregirl 4 года назад
Why didn’t you just install a meter/panel combo?
@rondianderson4402
@rondianderson4402 5 лет назад
KS required 18 inches from Windows.
@dh66
@dh66 4 года назад
Are there Windows on the roof I didn't see?
@2333jc
@2333jc 3 года назад
Some places it requires the meter to be 36" from windows.
@robertwillets5239
@robertwillets5239 Год назад
Is it common practice in Texas to put the breaker box on the outside of your home? I would think it leaves anyone the ability to shut down your security system should they be in the need for it not to be working. Spell control any of your other electrical systems from the outside. Because I seen it done once before and wonder why you want to do such a thing. Where I'm from you're always inside the house. The circuit breaker panel not the meter.
@srpchannel0169
@srpchannel0169 Год назад
Yes it is common. It does save money on the install. I always suggest putting it inside if possible. It can be on most interior walls. No closets or bathrooms and proper clearances per N.E.C. I have put them behind/by bedroom doors and even hallways. It depends on the person and what bothers them esthetically. Moving it inside can also increase the price $2,000 to $5,000 or more in price and that is also why it stays outside. Criminals can shut your power off from the outside even when the panel is inside because you still have to have a main disconnect outside. I tell my customers to lock the panel/disconnect, which is not code compliant, if it worries them. If there is a fire in the house the fire department is always told pull out the meter from the base.
@robertwillets5239
@robertwillets5239 Год назад
@@srpchannel0169 Missouri if the distance from the meter to circuit breaker panel is less than 10 ft you don't have to have the outside shut off breaker.
@99quintinsnapshot
@99quintinsnapshot 6 лет назад
Another 200 AMP FRAUD ... CROOK?
@edwardmarcihudson7543
@edwardmarcihudson7543 5 лет назад
This is a unfinished video skips half of information
@jamedlock83
@jamedlock83 Год назад
Wrong. . Texas code says you can have the meter as low as 3ft.
@srpchannel0169
@srpchannel0169 Год назад
You are correct. Oncor in Texas makes that determination. They like between 3 and 5 ft. The mast is usually much better supported when the meter is a little lower. That is why they require it.
@omarmelgoza2772
@omarmelgoza2772 Год назад
Were the disconnect
@srpchannel0169
@srpchannel0169 Год назад
The main disconnect is in the panel itself.
@georgelujan990
@georgelujan990 2 года назад
You are Fired
@javierpuerta8074
@javierpuerta8074 6 лет назад
nice and save
@user-sd9ws3ns8n
@user-sd9ws3ns8n 5 лет назад
الو
@tristonritchie3200
@tristonritchie3200 6 лет назад
NEMA.. this panel is arranged to drain.
@niteflyer3380
@niteflyer3380 6 лет назад
uhmm... why would anyone do overhead power? dig it up and lay things underground... why do overhead voltage? tree's and cars fall/run over lines, shuts down the power for days... 10 yrs from this video the home-owner will come to facts... underground it... I think I might win the bid on that job... is there any reason not to run underground? do think about it...
@IceCreamJones42069
@IceCreamJones42069 5 лет назад
Nite Flyer cost
@houseedge1507
@houseedge1507 5 лет назад
If they went underground it would have to be parallel and perp instead of b line. This would take alot more wire which means more money. But yeah in the long run underground would be the way to go I think because minus hurricanes and tornadoes you still have snow and most importantly ice build up. With those 4 elements it pretty much covers the whole county.
@angelgutierrez9858
@angelgutierrez9858 5 лет назад
Because its an overhead feed...Meaning the tansformer is on a pole not on Ground LoL...Just that simple..🤯
@HighestRank
@HighestRank 5 лет назад
Can’t have an outdoor panel together with underground feed, and for whatever reason, they seem to want or need an outdoor panel.
@megostop9650
@megostop9650 4 года назад
@@Gtbomb1 No, he's not. Sometimes there is an overhead feed that goes to a panel that is on a separate pole (about 2 or 3 feet high) and not attached to the main structure (at whatever distance away from your house you want) and from there the lines are run underground to the subpanel inside the house.
@SherriP
@SherriP 2 года назад
Jesus Christ is the son of God who died and rose three days later and loves all of you. He died for everyone and wants you with Him, to know Him and live for His glory. Come be saved eternally and spend time with Him to know Him. Be saved, free, forgiven, healed, delivered, baptized, whole and let Him show you how He is everything you need.🕊️ Living righteous and Holy because He's said to and paid for our way to live like Him. Ask anything in His name and the Father will do it 🙏 amen hallelujah praise God thank you Jesus 🙏 🕊️ 💕 🔥 🙏 💕🕊️🔥 I lift up everyone's prayers, wants and needs to You Jesus, please pour out blessings. May Your favor, grace and mercy be upon the world. In Jesus name come help us all. You know our needs and everything else about each of us. In Jesus name amen thank you Jesus praise God 🙏 Jesus, Help people to be rooted and grounded in Your love. That they are living in the truth being taught by You. 🙏 We are ambassadors of Christ. We should be living for and showing God, living for His glory🙏. We are to be an example of Jesus for the world to see Him and want to know Him and know Him more. 🕊️ 🙏🔥 💕 2 Chronicles 7:14 says, if My people humble themselves and pray and seek My face and turn from their wicked ways I will hear them from heaven and heal their land. 🙏 People need to turn from their wicked ways, Jesus paid for it. That's God stating it in that verse and there are more verses. People need to repent, to be cleansed by His blood and live Holy because He's Holy and righteous because He's righteous. Our God said to stop sinning in many many scriptures and He paid for everyone to be cleansed of sin (Isaiah 53), and to live how He said. He dwells in the Holy temple (your body) and said not to defile the temple. He said to defile the temple is death. He's always serious about everything He said to do. He's just as serious about what He said not to do. We live in obedience to His law, every word if it! He dwells within us all to be with and lead us in His ways. 💕 Deuteronomy 28 there are blessings for obedience and curses for disobedience. The whole chapter, and verse 46 is one example of generational curses. These go into the following generations, the 3 and 4th. Our children pay the price for our sin. Stop sinning you are sending consequences to yourself and to your loved ones, children. By God's law you are. If you don't believe me ask Him, in Jesus name may you see and know the truth in it's fullness. He's worthy of everything He said and paid for, so I implore you to do as God said. Jesus said If you love me you will obey my commands. Praise God thank you Jesus. In Jesus name 🔥 🕊️ 🙏 💕
@jamedlock83
@jamedlock83 Год назад
Are you a licensed electrician? If you aren't, then you are breaking the law by doing that yourself.
@srpchannel0169
@srpchannel0169 Год назад
Yes I am a licensed Electrical Contractor in the state of Texas TECL 22646.
@michaelraulerson3096
@michaelraulerson3096 3 месяца назад
In most states if you are working on your own house( not a rental or a flip) you can do your own wiring!
@ncastillo1014
@ncastillo1014 4 года назад
Not informative at all, skipped through everything I ACTUALLY needed to know.
Далее
КОРОЧЕ ГОВОРЯ, 100 ДНЕЙ В СССР 2
08:37
The Worlds Most Powerfull Batteries !
00:48
Просмотров 9 млн
Big Mouse 😂
00:13
Просмотров 134 тыс.
T4E - Service Entrance
11:34
Просмотров 116 тыс.
Full 200 AMP Electrical Service Upgrade Install
37:01
Просмотров 157 тыс.
Installing an underground electric service
48:07
Просмотров 227 тыс.
What is Ground? Earth Ground/Earthing
9:27
Просмотров 3,2 млн
КОРОЧЕ ГОВОРЯ, 100 ДНЕЙ В СССР 2
08:37