Тёмный

Explain principle of smart distribution panel with energy monitoring 

KinCony IoT
Подписаться 69 тыс.
Просмотров 3,8 тыс.
50% 1

#homeassistant #smarthome #smartcontroller #tuya #esp32project #diyprojects
Home Automation Distribution Panel Energy Monitor| IOT Project 2024!:
• Home Automation Distri...
Home Automation 8CH Raspberry Pi Distribution Board DIY | Smart IOT Project 2024 video tour:
• Home Automation 8CH Ra...
16CH Raspberry Pi Distribution Board DIY Video:
• Home Automation Raspbe...
32CH Distribution Board DIY Video:
• Home Automation 32CH D...
8CH smart distribution panel diagram download:
www.kincony.com/forum/showthr...
visit for more:
KinCony's website: www.kincony.com
Online Store: shop.kincony.com
Facebook: / kincony.smarthome
Twitter: / kincony

Хобби

Опубликовано:

 

1 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 30   
@arbazaa7295
@arbazaa7295 12 дней назад
Best explanation 👏🏻!! Upload daily video sir I'm waiting for your new video's 😊
@KinCony
@KinCony 12 дней назад
thanks.
@yedukondalumidde1900
@yedukondalumidde1900 22 дня назад
Your work explanation very very great🎉🎉🎉
@KinCony
@KinCony 22 дня назад
thanks
@Innovation_king
@Innovation_king 21 день назад
The best company I ever seen in wired automation...pls make Tuya + Home assistant devices...also pls introduce a solution like KNX DALI system..
@KinCony
@KinCony 20 дней назад
yes, in furture we will consider about Dali.
@jonathancolby9179
@jonathancolby9179 21 день назад
Thank you! I am glad your making nice products and I have noticed your English getting better year over year. I used the 868COLB for a customer and it worked good ! System design with manual failover is very good idea! I like the small power meter rings.
@KinCony
@KinCony 21 день назад
thanks, sorry, my English also is poor:)
@user-km6uu1mw7k
@user-km6uu1mw7k 21 день назад
Very good. I liked kincony products ❤
@KinCony
@KinCony 20 дней назад
@@user-km6uu1mw7k thanks
@ruimarinho
@ruimarinho 21 день назад
Thank you! Amazing work! Here the contactor is after the breaker but in previous videos it’s different - they are the other way around. Can you explain which system works better in each scenario?
@KinCony
@KinCony 21 день назад
this one is better.MCB before contactor.
@ibryxx
@ibryxx 21 день назад
i noticed that too.. my setup is breakers after contactors. 😅 tho it works great with H32B pro
@ruimarinho
@ruimarinho 21 день назад
The new CT clamps look very good. What’s the max rating? Are they factory calibrated or should we calibrate them individually at arrival?
@KinCony
@KinCony 21 день назад
not need calibrate , there are some different model of CT sensor, MAX support 100A version.
@fareedquraishi
@fareedquraishi 9 дней назад
Hi, can you please inform that how the wiring of a home is to be done as per your schema of DBs. As in South East Asia, Generally a single CB, controls a single room. In that sense, how should we go about thses type of DBs.
@KinCony
@KinCony 9 дней назад
you can make one DB, all wire connect with one DB. Or you can make multi DBs, every floor or every room use by a small DB, such as 8 channel or 16 channel version.
@walkastray007
@walkastray007 17 дней назад
Hey KinCony! I know it's probably obvious, but is there a reason we use a fuse instead of a circuit breaker? I'm quite new but would like to understand the design choice. Thanks! :D
@KinCony
@KinCony 17 дней назад
fuse only protect the DC12v power supply.others load all protect by breakers.
@martinspukitis1954
@martinspukitis1954 День назад
Can you make a smaller energy meter? 10 or even 5 channel?
@KinCony
@KinCony День назад
yes, will make it in furture
@ruimarinho
@ruimarinho 21 день назад
Does the DC contactor work manually if the DC power supply dies?
@ibryxx
@ibryxx 21 день назад
it should work..
@KinCony
@KinCony 21 день назад
sure, this is important
@ruimarinho
@ruimarinho 21 день назад
If I understood correctly, there are two redundancies: the A32 Pro software being broken where the manual switch can be used to trigger the contactor and the contactor itself if the A32 Pro dies or the DC PSU dies. Is this correct?
@KinCony
@KinCony 21 день назад
@@ruimarinho yes, you are right.
@samza9
@samza9 16 дней назад
Can you make EC PH control kits for sale? Bro
@KinCony
@KinCony 16 дней назад
use for agriculture?
@ruimarinho
@ruimarinho 21 день назад
What’s the primary reason for using DC powered contactors?
@KinCony
@KinCony 21 день назад
DC contactor will not cause interference
Далее
Advanced Smart Home Dashboards Made EASY
9:44
Просмотров 1 млн
Are You Maximizing Your Loxone RGBW 24V Dimmer?
22:35
Просмотров 1,3 тыс.
Open Source Smart Home HUB 2.0 for Home Assistant
20:36
Отнимают ребенка ч.7
0:55
Просмотров 3,6 млн
СЕРЕГА ЕЛЫ ПАЛЫ СКОНЧАЛСЯ!!!
0:59
Что она делает?
0:34
Просмотров 11 млн
Сыграл на опережение #юмор
0:20