Extracting oil from a Voltage Regulator - 7200 volts 

Bobsdecline - Lineman blogger
Подписаться 130 тыс.
Просмотров 130 тыс.
50% 1

Hey Everyone!
Just another responsibility of being a Lineman... Oil Samples! I often wondered how many other companies out there do this?? Its certainly not something guys are going to do on storm work, so I don't ever see it when helping out in other areas.
After extracting the oil, we send it off to a lab where they do all kinds of tests and "science" stuff. (way over my head!✈️) These tests can often find clues within the oil that a particular unit may be about to fail!
Oh! Here's the link if you want to check out my costume 😁👻
This one's from a few years ago now, I changed it up a bit each year!
➡️ • Halloween Stilts Costu...
😁🍻 Cheers!
** These video's are NOT intended for training or D.I.Y. Only properly trained and authorized personal are allowed to work on this equipment. Always adhere to work methods and procedures particular to the company you are working for. **
Don't forget to drop a 👊 along with where you're watching from!
Huge thanks to my Patreons!
➡ / bobsdecline
Music courtesy of:
"All good in the wood" by Audionautix
RU-vid audio
#Bobsdecline, #Beingalineman, #Lineman

Опубликовано:

 

4 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 317   
@skeeterskoville9226
@skeeterskoville9226 2 года назад
Regulators make me nervous. Lol especially working hurricane damage and restoration. Great vid!
@dannynormile3550
@dannynormile3550 2 года назад
I just pulled oil samples out of 2 station transformers, but never out of voltage regs, unless we’re performing acceptance testing. Great video, Aaron
@inothome
@inothome 2 года назад
I DON'T miss taking oil samples, we used to have to take samples of all our equipment. Now it's contracted out. One important point when taking oil with a syringe for a DGA (dissolved gas analysis), which you most definitely were with a regulator. After you draw the sample and the oil sits, if you see an air space, do not burp the air. That is some of the dissolved gas coming out and that is what they are testing for. We had a guy years ago, he would take samples, let them sit for a day or so, them burp the air out. Since the instructions were to completely fill the syringe, but didn't mention that if you saw after it was full to leave it. Not good to do for a DGA! But it is amazing what they can look for and determine the health of the equipment based on what chemicals they find or don't find in the oil. Much more than just moisture and dielectric strength. Thanks for the video and work safe.
@Bobsdecline
@Bobsdecline 2 года назад
Excellent advice! I didn't know that, Thanks for sharing 👊👊
@ocsrc
@ocsrc 2 года назад
There are so few people who actually know how things work, how to repair them, and keep the world working. And almost all of them are unsung heroes, never getting recognition for their work, and often times getting screamed at by people who have not a clue, can't even fill their own gas tank, but they keep on, doing the job, while taking the abuse. I love the show Undercover Boss They have the owner or CEO and they are given entry level tasks to complete, and they do thousands of dollars in damage in just seconds, while the actor they hire to be the " competition" against the undercover boss does the job flawlessly It shines a stark spotlight on how the people at the top are completely useless If all of the people at the top, the CEOs, if they disappeared for a year, no one would notice But let just one of the people who they say aren't worth minimum wage not show up, and the business have to close, the power goes out all over the city, state, country And with the new corporate model of 1 employee doing all the work that literally used to have 6 employees, if that one person doesn't show up, the businesses literally have to close I really wish the little people would strike nationwide till their demands were met for a living wage, but they would all be labeled domestic TERRORISTS and the military would be sent to put them down, literally
@mikel9567
@mikel9567 2 года назад
I'd like to see how you add or change the oil in these. With our last windstorm we were working alongside PUD to get the roads back open and they brought one of these out to replace what I assume was a damaged one. These things are huge up close. Much bigger than I thought. Got to give credit to those power guys, they did quick work. We had a mile long stretch where the poles were snapped or broken and they had the entire stretch fixed with brand new poles and wire in less than a day. Not an easy task when massive trees are down blocking the road too.
@michaelcatchpole7230
@michaelcatchpole7230 2 года назад
They are indeed a lot bigger up close. When I was in high school the local power company had a booth at a career fair. They had one of these regulators that probably was built for a trade show - the casing was glass or plastic so you could see the insides of it and there was no oil. It didn't have power to the 7200v windings of course but they demonstrated how the tap changer worked and you could actually see the parts moving around inside because of the glass case.
@chasetrent2450
@chasetrent2450 2 года назад
Hey Mike as a substation electrician we deal with regulators on a normal basis. From what I can tell you at least for the company I work for we do not change or add oil to regulators. If they fail the Kellman test (oil sample test) the whole unit gets replaced.
@jovetj
@jovetj Год назад
Yeah, they're like 7-8 feet tall. Big cans!
@estouch
@estouch 2 года назад
Love the care that is taken for each job that you do. Can tell that you love what you do. Gives me allot more respect when the power goes out, to give the lineman a break
@Marks-Garage
@Marks-Garage 2 года назад
I have a decent story regarding sampling of a 400kv bushing once. Transformer was only 9 years old. During routine maintenance we took a sample. The tell tale sign that something was wrong with the bushing was that when my coworker undone the sampling point cap it shot up in the air with the pressure inside. When the results from the sample came back it was full of acetylene and ready to explode. Bushing was changed and transformer returned to service. In the UK some of our transformers are fitted with Hydrans that monitor the oil quality constantly and give a good indication of equipment health. We also have trailers that can be attached to monitor the gas real time. They tend to use these when a transformer is near end of life and a replacement can take up to 18 months to build
@mybeachshack
@mybeachshack 2 года назад
Satisfying & informative video Sir. Do you ever smell the oil as well as (just) look at it as a preliminary inspection ?
@jameswyatt1304
@jameswyatt1304 2 года назад
Wow! How does it get pressurized with Acetylene? Someone thought it was nitrogen or what?
@Marks-Garage
@Marks-Garage 2 года назад
@@jameswyatt1304 When the insulation starts to break down you get arcing occurring within the bushing. The by products of arcing are lots of different gases and acetylene being the most explosive of all the gases. The transformer was only 8 years old so it was lucky that we found the issue during maintenance. It was a 1000MVA transformer so a failure of a transformer that size would of been pretty spectacular.
@jovetj
@jovetj Год назад
@@Marks-Garage Yes! Regular maintenance!
@christopherrichardson5352
@christopherrichardson5352 2 года назад
I've never heard of Power Line Technicians taking gas-in-oil samples. That was always a task of Substation Technicians like myself and I don't recall ever taking one from a downline voltage regulator. We only did these tests on our main substation and generation transformers on a yearly basis. In addition we would always start with the syringe completely emptied of air and do a couple of "flushes" with the oil to be tested before doing the final fill to be sent off to Morgan Shaffer for dissolved gas in oil analysis. As well we would not do any type of sampling on a transformer with a "negative" pressure on the tank since opening the main valve at the bottom of the tank could possibly draw in air bubbles which could then work there way up through the oil and the windings and cause a fault. This of course was only an issue on nitrogen blanketed "sealed" tank transformers. In this case we would try again on a warmer day or add nitrogen to the top of the tank until a "positive" pressure could be seen on the pressure gauge. In addition we used mason jars to take larger samples which we would then take back to the shop to perform power factor and dielectric breakdown testing.
@dannynormile3550
@dannynormile3550 2 года назад
I’m a substation technician as well and I agree with your post. Certainly not discounting any content of this video.
@Bobsdecline
@Bobsdecline 2 года назад
Our sub techs do the majority of this work (within our sub yards). Biggest reason we do it as well is because of the mounting height. We cover the VR's and Or's out on the line. There wasn't quite an actual negative pressure, just not enough pressure to push the oil out into the syringe as a result of the cold temperature. We cease testing once temps dip below 0. Great info also by the way, thank you! 👊👊
@christopherrichardson5352
@christopherrichardson5352 2 года назад
@@Bobsdecline No worries Aaron and as Daniel said I'm not trying to discount the content of your video either. As always you did a great job in this video keeping things accurate and concise. Cheers brother.
@chosen1one930
@chosen1one930 2 года назад
Every country or even company does it differently im sure
@earlestes8649
@earlestes8649 2 года назад
@@chosen1one930 that’s what I was getting ready to say. Work orders are different on the same jobs with different companies, they will put as much on you as they can get by with!
@Bobsdecline
@Bobsdecline 2 года назад
After extracting the oil, we send it off to a lab where they do all kinds of tests and "science" stuff. (way over my head!✈️) These tests can often find clues within the oil that a particular unit may be about to fail! Oh yeah, this is more footage from back in October 😬 hence the mention of Halloween👻👊👊🍻 My costume ➡️ ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-K_0CVLhUCEI.html
@BlackBaron705
@BlackBaron705 2 года назад
You mentioned that you send off the syringe for testing, but what do you do with the other 90% of the oil you drained into the jars?
@Bobsdecline
@Bobsdecline 2 года назад
Jars go too! I think they use the larger amount in the jar for di-electric testing. I vaguely remember doing that back in 2004 when training with some sub techs
@generatorjohn4537
@generatorjohn4537 2 года назад
We use to have a lab in house of my old company but now they use Doble out of Watertown, Massachusetts. Important information is captured from these samples. They can tell you whether or not the equipment can continue to remain in service.
@ke6gwf
@ke6gwf 2 года назад
A lot of heavy equipment gets this type of testing regularly on engine oil and other fluids, especially Caterpillar stuff. When an oil change can cost thousands of dollars, plus down time, and not changing the oil in time can cost tens of thousands of dollars, it makes a lot more sense to test it for $25 so you know exactly when it needs to be changed, as well as being able to see if you have a bearing or cylinder or something starting to go out, since each part in the engine uses a different alloy, and so by looking for the phosphorus or brass or whatever in the oil sample you can see wear metals. Plus seeing if the additives are breaking down, it's getting contaminated, etc. A lot of trucking fleets use oil sampling as well, either to determine when to change the oil, or find the average life for a particular engine hauling a particular type of load. Trucks in stop and go traffic will wear the oil out faster than trucks on the open road, etc. FYI, if you want to test your own oil in a pickup or whatever, you can buy the prepaid oil sample test kits from Caterpillar (and other places too), and it comes with a mailer to send it to the lab. They do coolant etc too.
@Bobsdecline
@Bobsdecline 2 года назад
That's great info Ben! I didn't realize that, thanks for sharing. Cheers!🍻
@rogerbeck3018
@rogerbeck3018 2 года назад
thank you for the ongoing insights to the electrical distribution industry - I very much appreciate your efforts. From my comfortable desk in suburbia I am "learning"
@williamdegnan4718
@williamdegnan4718 2 года назад
Wow! Haven't seen glass syringes in 60 years. Back in the day, my dad had a project which required him to extract samples of transformer oil from some respectably-sized distribution transformers.
@dannynormile3550
@dannynormile3550 2 года назад
We use them regularly.
@christopherleubner6633
@christopherleubner6633 2 года назад
They are called gas tight sampling syringes, made of glass and teflon. Pretty expensive. They can also safely be filled up with some pretty horible chemicals as well.
@williammay5300
@williammay5300 2 года назад
You are the Doctor for the electric grid...
@MXSLICK
@MXSLICK 2 года назад
I did work on testing/identifying dioxin contaminated oils used heavily until it was banned many decades ago. Lots of this equipment exists in the wild. Knowing about PCB/Dioxin and it's effects on human health made me outright quit. Too much personal risk even with proper handling. Keep an eye open for old transformers, you simply don't want to have contact with that poison.
@the_hamrat
@the_hamrat 2 года назад
Were you using HPLC or GC for dioxin?
@BlackSoap361
@BlackSoap361 2 года назад
After I found out how much PCB/DLC is in some fish, I severely cut back how much seafood I eat.
@keithfork8663
@keithfork8663 Год назад
You are so correct.
@henrycems
@henrycems 2 года назад
I think the nurse used a syringe-like that drawing my blood the other day LOL. Keep up the great work.
@Bobsdecline
@Bobsdecline 2 года назад
🤣 Them ones hurt!! 👊👊🍻
@ghalgren
@ghalgren 2 года назад
As a Lineman, I have performed these tasks many time inside and outside of sub stations.
@kevinpoore5626
@kevinpoore5626 2 года назад
Hey it's no fair when you're the first one on your channel LOL be safe keep up the good work
@robertlapointe4093
@robertlapointe4093 2 года назад
Hi Aaron, great to see preventative maintenance being done. So rare these days with many providers thinking it is cheaper to wait for failures (and screw the customers). I've used syringes like those for more than 40 years, for handling air-sensitive chemicals, mostly pyrophorics like triethylaluminum.
@psykolikwid
@psykolikwid 2 года назад
As always, thanks so much for all the work all linewomen/ linemen do!!
@thomasmleahy6218
@thomasmleahy6218 2 года назад
I sent you a notice about a glove company in Chicago called Kunz Gloves. Looks like they have a wide variety of equipment. They've been in business a long time. I used to buy mittens and liners when I was still working on a large Chicagoland freight railroad, through some bitterly cold winters in the '70s. Hope this helps, it's pretty hard to keep out rain, very miserable when it's 40°F and blowing sideways, sometimes partially frozen. Always did like working during a snow storm, though. Thank You for your fact based videos, and appreciate the thorough procedures you follow. Regards, T.
@Bobsdecline
@Bobsdecline 2 года назад
I do remember remember seeing a mention of "Kunz" somewhere. It must have been your. I'm going to screen shot this comment right now so I don't lose it and I'll check it out! Appreciate it ! 👊👊
@bgundercover
@bgundercover 2 года назад
I like the cap you had on in the shop.
@bobgallo3775
@bobgallo3775 2 года назад
Good post, never knew that was part of the duties of being a lineman.
@brothers4ever2
@brothers4ever2 2 года назад
Be careful taking samples with the live regulator you might accidentally suck out some electricity.
@omaristephens2143
@omaristephens2143 2 года назад
Been meaning to say: love the hat 👍🏽 🏳️‍🌈 Cheers from the Bay Area in northern California. Not a lineman, but I love learning about this stuff. Thanks!
@Bobsdecline
@Bobsdecline 2 года назад
Thanks, Cheers Omari!
@endtimes2100
@endtimes2100 2 года назад
I nvr knew there was oil inside those transformers until I started watching your channel.
@ntsecrets
@ntsecrets 2 года назад
I had a circa 1950s transformer leak all over my lawn - they had to replace it.
@gorillaau
@gorillaau 2 года назад
@@ntsecrets Did they replace the lawn?
@ntsecrets
@ntsecrets 2 года назад
@@gorillaau it was like a 2x2 foot square... so no. But they assured me that the 1950s oil had "little to no PCBs" lol. It did grow back.
@gorillaau
@gorillaau 2 года назад
@@ntsecrets LOL. Little to no PCBs, right. :) It sounds like ACS which depending who you ask is either American Cement Sheeting or Abestos Cement Sheeting. I have adopted it from Australia.
@ntsecrets
@ntsecrets 2 года назад
@@gorillaau actually the power company at first did not want to replace it, so I called the EPA state agency and they had a truck out within an hour to replace it!
@oicfas4523
@oicfas4523 Год назад
"Checking the oil" in some electrical equipment sounds like one of those made-up tasks you prank newbies with 😂. Like "blinker fluid" or the "keys to the sea chest."
@pressrichardson6407
@pressrichardson6407 2 года назад
Love your videos, planning on going to line school next august and getting into the trade! Incredibly excited and eager to get going! Have always had the dream to work on the most powerful force on earth and you have been a huge inspiration to get me ready to go and make the jump! Thank you and keep these videos coming! ⚡️
@jovetj
@jovetj Год назад
Money is the most-powerful force on Earth. Second place goes to the Strong atomic force. Wife force comes in third. Electromagnetic force comes in fourth.
@sethdeppen8439
@sethdeppen8439 Год назад
I work for an environmental company from the United States that responds to the transformer spills and pumpouts, we also take samples, ours are to determine pcb content in the oil, prior to late 1960s, pcb oil was used and long term exposure can lead to cancer and health problems for those who might not know. I find it very interesting to see the day to day life as a lineman and how it all works. Stay safe out there.
@cerealchild166
@cerealchild166 2 года назад
That is interesting!! I like how you explain things, clear and simple!!
@JohnThomas-lq5qp
@JohnThomas-lq5qp 2 года назад
Back in the late 1970's POS GE service department would check our 13.200 & 4,160 volt transformers. They would test it what looked like a basic Megger to test oil. If reading was low they would run oil thru a blooter press for a few hours. Halve ass GE used the same hoses on transformers so ended up contaiminating one of the 13,200 volt transformers with PCB'S
@the_townleys
@the_townleys 2 года назад
Morning Aaron🤝 Going over transformer maintenance checked out the tap changer counter for an OLTC..extracting oil samples from a tap changer...cool stuff.
@marillima6350
@marillima6350 2 года назад
Love your videos man
@Bobsdecline
@Bobsdecline 2 года назад
Thanks! 🙏👊
@mpeg2tom
@mpeg2tom 2 года назад
Do you ever check the potential on transformers and voltage regulators whose cases "are supposed to be" bonded to ground before you touch them?
@credit__devin
@credit__devin 2 года назад
I freaked the fuck out watching him do that
@AureliusR
@AureliusR Год назад
@@credit__devin He had probably already tested it before watching the video. This guy is very meticulous.
@andrewsmedy7799
@andrewsmedy7799 2 года назад
Thanks I like to wach all your videos
@johnwalker890
@johnwalker890 2 года назад
Good job Aaron.
@danyoung5346
@danyoung5346 2 года назад
Yo another great video Keep on making them.. people need to see where and how they get their Electricity
@thetooth
@thetooth 2 года назад
Thanks for the info, I also take samples to make bio diesel for my truck, there are a lot of transformers in my area so no need to pay for fuel these days.
@cobrastrike5793
@cobrastrike5793 2 года назад
Hey man from Wallingford Connecticut USA 👊 stay safe and happy Thanksgiving
@Dingomush
@Dingomush 2 года назад
How many times can you sample the oil like that before it needs topping up? Love the vids. I’m not a lineman, I don’t play one on TV. lol. Just always wondered how most of that was done, then I stumbled across your channel.
@pierreletourneau722
@pierreletourneau722 2 года назад
I used to work for Hydro-Québec in 1971 and when we took oil sample from big transformers and breakers, we had to save some on the side. A lot of old guys were using old oil for rubbing on their rhumatism, I knew it was not good, but since I was beginning my 'career' , I did not argue. The oil had to have suffered some arcing to be good.....Of course at that time the oil was full PCB!
@jovetj
@jovetj Год назад
Ouch!!
@avlawns3037
@avlawns3037 2 года назад
mmm Dioxin! Timesbeach says hi.
@timjorden8329
@timjorden8329 2 года назад
Always very interesting. Thanks
@Elizondough
@Elizondough 2 года назад
Why isn't there a regular service interval to just change the oil? Seems like over time if you keep draining to oil to check it you have to add more eventually right?
@charlesbaker6403
@charlesbaker6403 2 года назад
Mineral oil is considered hazardous waste so utilities in different areas properly want to minimize the amount they have to dispose of.
@Bobsdecline
@Bobsdecline 2 года назад
They get a top up about every 10 years! While it's a big jar, it doesn't take much from those big tanks
@ke6gwf
@ke6gwf 2 года назад
It's actually not ideal to change oil on a regular schedule, because oil doesn't wear or get contaminated on a regular schedule. Imagine a car in Florida by the beach, and one in Nevada in the desert. Same miles per day, which will actually need an oil change first? With cars we are used to fixed schedules, but that's just for convenience, and because it's a small cost to change the oil. But when you get to larger engines, heavy equipment, etc, the best practice is to periodically test the oil, looking at additive levels, oil breakdown, wear metal levels, contamination, etc, and only change it when it actually needs it, partly because if it's under mild conditions and light use, it may be able to go twice as long and thus save a lot of money, but on the flip side, if it's under heavy use or harsh conditions, or has a leak or something wearing badly, it may need to be changed much more frequently to avoid engine damage. Also, if you see a high level of a particular metal in the oil sample, you can get early warnings that a bearing is going out, or something else is having issues, so that you can plan for preventative maintenance before it fails, or replace a bearing before it destroys a crankshaft or block. With this application, you are not just checking oil condition, you are basically taking a blood sample from the device, so you can actually see if the device itself is having any problems, whether major ones like a leaky seal allowing moisture in, or subtle ones like arcing inside that will leave dissolved gasses and probably elevated copper or aluminum levels in the oil. And if you find those problems, then you can repair or replace the unit before it fails. Just changing the oil won't identify the unit faults.
@mpeg2tom
@mpeg2tom 2 года назад
PCBs are still found at permitted levels in a small and decreasing number of in-service transformers...
@Elizondough
@Elizondough 2 года назад
@@Bobsdecline TY sir
@JimwombatLand
@JimwombatLand 3 месяца назад
use to take samples and test the oil , pcb's ,low arc range , recomend changing .
@longviewstud26
@longviewstud26 2 года назад
Support educational I had no idea
@imeprezime1285
@imeprezime1285 2 года назад
Didn't know that was a part of your job. Quite surprised!
@assassinlexx1993
@assassinlexx1993 2 года назад
Sometimes it is not if you are a good Lineman but how good a secretary you are. People say electricity keeps world going Nope paper work. 🤦‍♂️👷
@chosen1one930
@chosen1one930 2 года назад
I'm surprised more people aren't stealing ground wires from the poles.
@teh_supar_hackr
@teh_supar_hackr 2 года назад
Not sure why I got recommended this, but have watched it anyways
@Bobsdecline
@Bobsdecline 2 года назад
Hah sweet! 🍻
@jolyonwelsh9834
@jolyonwelsh9834 Месяц назад
Water is heavier than oil therefore it tends to settle at the bottom. If there were any contamination with water entry, you should notice it right away.
@russianlineman4059
@russianlineman4059 2 года назад
Круто! У нас пробы масла берутся только из силовых трансформаторов на подстанциях напряжением от 35 кВ и выше, а на линиях 10 кВ у нас применяются вакуумные трехфазные выключатели.
@davidca96
@davidca96 2 года назад
Whats fun is when you see a failure and the oil spews out and catches fire. Ive seen that a couple times, its pretty wild. Get that stuff hot enough and it burns.
@TorrentPerformance
@TorrentPerformance 2 года назад
In a apocalypse type situation, him showing you this is vital for the ability to drive. Maybe not the new diesels but older diesel engines will run on the mineral oil if the oil supply chain dies in a event. Just get a large tarp and brace it on all four corners and run a small round in the bottom and badda boom you have fuel to run your diesel if you can catch it. It will render the unit completely useless but it may get you farther down the road in a apocalypse situation. It does work and could be vital info to save you and your family sometime.
@M3rVsT4H
@M3rVsT4H 2 года назад
Just be aware that not all Transformer oil is Mineral oil. Not sure how some of the synthetic esters they use these days will go. Might be fine.. Might be a fine mess to fix.
@stephenrowley4171
@stephenrowley4171 2 года назад
Trick is not to break the tap off like a college did on a JW420(large 275kv oil filled circuit breaker). Had to wedge a bit of wood in there to stem to flow. So he could go get the circuit tripped out and arrange and emergency oil tanker
@jovetj
@jovetj Год назад
Oh dear!! 😲
@shellyrobinson2795
@shellyrobinson2795 6 месяцев назад
wow cool i really hope you added some oil back after doing that as if it gets too low or no oil at all it might explode on you guys
@dLikesDDs
@dLikesDDs 2 года назад
having worked on oil spill/pipeline spill clean ups, some from leaked transformers, that mineral oil was by far the worst as to how far into the ground it leeched
@DoubleVoddy
@DoubleVoddy 2 года назад
this is awsome i have the same job
@electroshed
@electroshed 2 года назад
Love the Oakley pride cap! 😍🏳‍🌈
@linehandibew6205
@linehandibew6205 2 года назад
Wish our utility installed regulators this way. Instead of a 3 pole stand for the bank they have them each hung on their own individual pole in a row. A B C. And they don’t have bypass switches. They are actually tapped directly to the line. Their reasoning is they down want anyone to be able to just throw in the byspass unknowing that they must be in neutral position. Makes sense but it makes it interesting when you have to put them on line to zero them out.
@hallgrimurkhallgrimsson1200
@hallgrimurkhallgrimsson1200 2 года назад
I would've thought the sediment was nessacery in the oil test since it would show how much material has dissolved into the oil
@mikeznel6048
@mikeznel6048 2 года назад
Howdy Aaron. Hope all is well with you amd your family!
@Bobsdecline
@Bobsdecline 2 года назад
Hey Mike! Thank you and hope all is well with you and yours! 👊🍻
@marcdich9066
@marcdich9066 2 года назад
aahhh yes the regulators are grand standing upthere just regulating lol anyway happy thanksgiving to you and your family
@Bobsdecline
@Bobsdecline 2 года назад
Thanks Marc! Cheers!
@martinelectrician5637
@martinelectrician5637 2 года назад
Fantastic 😍😍
@sethtaylor5938
@sethtaylor5938 2 года назад
They do a DGA (Dissolved Gas analysis) on the transformer oil, usually Shell Diala. Why? Arcing in the oil when contacts operate, creates acetylene gas. All regulators have moveable contacts in the oil that are part of the tap changing mechanism. Usually this test is done based on a calendar or based on a mechanical counter at the regulator or recloser that counts the number of times the electrical contacts submersed in the oil have moved. At First energy we collected this data based on quarterly inspections. If the amount of dissolved gas exceeds the parts per million threshold, the oil has to be replaced. Acetylene is a combustible explosive gas. Also the oil has an affinity for moisture which has to be analyzed. We did not do DGA on fixed PAD and pole transformers as there are no contacts in the oil that move or operate on a regular basis. Some transformers have a NLT (NO Load Tap Changer) that should only be moved when the device is ***de-energized***. This is how we avoid making acetylene gas in the transformer oil.
@Bobsdecline
@Bobsdecline 2 года назад
Excellent explanation! 🙌🤝🍻
@NkRemTeh
@NkRemTeh 2 года назад
Спасибо, интересная тема про трансформатор)
@pleasureincontempt3645
@pleasureincontempt3645 Год назад
I love that physics permeates everything. Head is head whether you work in Wastewater or Hydro. I enjoy your perspective and insights Aaron. Wonderful work as always! Thankfully I’ve never had to experience work in Delta P.
@lokiva8540
@lokiva8540 Год назад
Do you guys have any HDD pipe for grid, e.g. river crossings done UG and not cheaper aerial? Those also get oil testing, for pollution, oxidation, water influx, dielectric breakdown, and signs of lightning hits. The technology shift from paper conductor insulation of that uniform spacing and twist triplex to modern plastics, and estimated life increase from 35 to 80-ish years, has yet to undergo a full life cycle, as tech experiments on further design improvements are being done at some specialized utility systems lab sites. Imagine the nuisance if you had to replace a 14,000 foot pull of 1200 amp, 230 kV cable in 12" diameter thick wall pipe, with one intermediate splice box under the middle of a river.... By comparison, swapping out 7200 volt, 600 amp step regulators is routine and easy. In those systems, oil is pumped back and forth between reservoirs at either end of the pipe, and does all of improve heat transfer from I^2R losses, prevents moisture influx, acts as further insulation, and quenches any irregular corona fields. Imagine if you had all 3 grid phase legs, at voltages that get 6 or 10 foot separations when aerial, inside one 12" pipe....
@mrmatt2525able
@mrmatt2525able 2 года назад
Love the videos!
@tehlaser
@tehlaser 2 года назад
I'm curious why they want a jar and a syringe both. I would have assumed the syringe would be all the science types would need.
@Bobsdecline
@Bobsdecline 2 года назад
I think they need a larger volume for the di-electric test
@gregcaples4356
@gregcaples4356 Год назад
Aaron (or anyone knowledgeable) please give an explanation of what is the proper way to interpret oil levels with a ball-in site gauge.
@navasmnavasmnavasmnavasm8823
@navasmnavasmnavasmnavasm8823 2 года назад
Allahu bless you care and health for workI am Indian (Kerala)god's own country Electricity Lineman
@Bobsdecline
@Bobsdecline 2 года назад
Thank you🙏 cheers!
@AureliusR
@AureliusR Год назад
Oh wow, this is right at Crossroads Pentecostal! I know where that is :)
@redsquirrelftw
@redsquirrelftw 2 года назад
3:31 it sounds like you're speaking from experience haha. Actually I'm kind of curious how those regulators work, I assume it's basically an autotransformer, but how does that work with only 1 wire going in then out? I guess basically same idea as single earth wire return?
@jovetj
@jovetj Год назад
One side of the transformer is connected together. Both the incoming neutral/ground and the outgoing neutral/ground are connected, and even share just one bushing which you can see in the video. Generally the incoming wire ratio is fixed. The outgoing wire ratio has the tap changer. Most tap changers I've read out on regulators have 32 positions with each position having a certain additional deviation (like 1.5% V) off of neutral. The box at the bottom of the pole that the big black wound-up cable runs to monitors the voltages and adjusts the taps automatically as needed to keep the output voltage the programmed level.
@damonabets3779
@damonabets3779 2 года назад
Very cool video! I’m not familiar with oil filled voltage regulators(I usually work with PCB boards) but if you took oil samples every year wouldn’t the oil eventually run out of oil in the voltage regulators? Keep up the great content and stay safe up there!
@jovetj
@jovetj Год назад
Yeah, a syringe-worth didn't seem that bad, but that jar... was that close to a liter? I hope they check the oil windows after they're done, too.
@blockisle9
@blockisle9 2 года назад
You pull oil while energized? I’ve heard of transformers exploding when an air bubble from pulling oil exposed the windings creating an arc.
@willallison1136
@willallison1136 2 года назад
He checked the site glass first. I think that's probably why.
@rustblade5021
@rustblade5021 2 года назад
yes i've heard of that happening when there's an existing fault which has filled the air space with explosive gases... I would suggest a hazard assessment for this task
@generatorjohn4537
@generatorjohn4537 2 года назад
They check to ensure it's not under a vacuum.
@rshintss
@rshintss 2 года назад
Was just going to say the same thing. If it's a vacuum in the tank that air bubble being pulled in could cause an arc in the tank!
@Bobsdecline
@Bobsdecline 2 года назад
I say negative pressure in the video as it acts like that with the syringe in place, but it isn't quite there yet. The initial drainage into the jar comes out fine, there just isn't quite enough force to overcome the pressure from the gas within the syringe and it's tiny hole. Once temperature drops below zero degrees we will cease any sampling until next spring. There are some pieces of equipment that we de energize before sampling
@grahamek86
@grahamek86 2 года назад
Please tell me you carry another adjustable spanner. I can only imagine the expletives that would resonate round the area if I dropped it.
@plasmaman9592
@plasmaman9592 2 года назад
My neighbors kid was shooting holes in transformers draining the oil out of 9 different transformers
@heyyy4783
@heyyy4783 2 года назад
You didn't use the syringe correctly! You're supposed to plug in the syringe and let some oil spill out of the vent that goes off to the side, THEN you rotate the syringe valve to direct the oil into the syringe. By not doing this, you contaminated the sample with the air that was in the needle.
@xephael3485
@xephael3485 2 года назад
6:48 if you used clear jars it would be easier to tell if oil was actually contaminated...
@Bobsdecline
@Bobsdecline 2 года назад
To be honest I'm not sure why the jars are ordered tinted like that!
@BlackBaron705
@BlackBaron705 2 года назад
@@Bobsdecline I would assume to prevent UV breakdown of the sample.
@bobsoft
@bobsoft 2 года назад
@@BlackBaron705 Much like beer bottles. To prevent it oxidizing
@Bobsdecline
@Bobsdecline 2 года назад
I was thinking that, but then wondered why the syringes were clear 🤔. That's gotta be it tho!
@xephael3485
@xephael3485 2 года назад
@@Bobsdecline yes if they're going to a lab they probably don't care if you can see the sample...and want to protect it from light breakdown. Thanks for responding all.
@wawrzynzatorski5631
@wawrzynzatorski5631 2 года назад
Taking oil samples for testing for the content of eg cellulose, gases, etc. I see that the structures are made of wood, how do you keep them in good condition, there is no decay?
@JimwombatLand
@JimwombatLand 3 месяца назад
my problems were getting oil to come out the port, someting it would not flow out ...valve not working.
@aspopulvera9130
@aspopulvera9130 2 года назад
Do that mineral oil also had a second function like a cooler of some sort?
@robbyharrison9915
@robbyharrison9915 2 года назад
Hey eric i love watching u and buy the way i was born on halloween texting from gainesville fl gator country
@zyrppa
@zyrppa 2 года назад
Those are odd voltages compared to Finlands 20kv, 110kv, 220kv and 400kv.
@TheKdizzle1971
@TheKdizzle1971 2 года назад
Be safe oooooooooooooooooot there in Canada
@exinfocompany
@exinfocompany 2 года назад
My Ford Transit 2.0tddi is working great on oil from transformer. It runs more quiet than diesel 😂
@tubeDude48
@tubeDude48 2 года назад
How do you know that the level inside the Regulator isn't too low!?
@IIGrayfoxII
@IIGrayfoxII 2 года назад
Are those frayed conductors on that pole sticking out at 3:50
@adamscott4512
@adamscott4512 6 месяцев назад
The gears turn counterclockwise
@hariranormal5584
@hariranormal5584 2 года назад
6:29 the cables just below this are they Fiber/Copper for network purposes?
@topduk
@topduk 2 года назад
In Africa they use that oil for frying street food.
@kisielthe1st
@kisielthe1st 2 года назад
forbidden broth
@joshuapk9808
@joshuapk9808 2 года назад
It always seems like those VR's or tapchangers are near a church! In my "roaming area" there are a couple of sets of those and both sets of them are in front of a church. Before I knew what they were I was really curious as to why a church would need 325kW to praise the Lord lol...
@Bobsdecline
@Bobsdecline 2 года назад
Lol, it's true tho eh!? 🤔🤔
@ezquimal
@ezquimal 2 года назад
Why don't use dry transformer?
@AlanTheBeast100
@AlanTheBeast100 2 года назад
3:50 badly frayed guy wire (upper right of frame)?
@danbrey9357
@danbrey9357 2 года назад
Very cool videos. I appreciate the Chanel. One question about an observation- I notice not all tools have a wrist lanyard or other tie off. Before university and becoming an EE I apprenticed in a rigging related Industry. There any tools with overhead workers had to have have a security line in case dropped elevated. Thoughts and perspectives from your industry? I am sure there is always a compromise where one safety mitigation might make another factor more hazardous. Cheers.
@rayraap3905
@rayraap3905 3 месяца назад
Why two oil samples per transformer?
@weazeldark3983
@weazeldark3983 2 года назад
Surprised they don't use mcus to measure it live while in use Wouldn't be hard to measure most of the values and send data stream over cell network
@johnnyb8629
@johnnyb8629 2 года назад
interesting, Im an HVAC technician so I too work with voltage and mineral oil in that hermetically sealed compressors use mineral oil to lubricate the compressors and electric motors inside the hermetic cans. tell me this, are the transformer cans put in a vacuum before they are filled with mineral oil? a refrigerant system as well as the compressor must be put in a deepvacuum below 700 microns before refrigerant is added but this also includes the oil as well . I'm also wondering if you have any guidelines to megohm readings and oil contamination. we can determine how contaminated a system is by taking a megohm reading on the windings to determine if a system can even be cleaned or it must be replaced.
@alwayslost3008
@alwayslost3008 2 года назад
I work in the HVAC field as well, we take oil samples from our compressors and send them in for testing on a yearly basis. Moisture, acidity, viscosity and any abnormal particles from wear on parts. I'm from South Africa and the company we use is called Wearcheck.
@johnnyb8629
@johnnyb8629 2 года назад
@@alwayslost3008 interesting, I'm going to look for that service here...
@alwayslost3008
@alwayslost3008 2 года назад
@@johnnyb8629 We are like a third world country, I'm pretty sure you'll have a similar, if not much better, service there.
@darkwinter6028
@darkwinter6028 2 года назад
What’s up? Uhhh… power lines? 😜
@ntsecrets
@ntsecrets 2 года назад
How do you add / top off the oil when it gets too low? Guessing at some point that happens If you’re testing it on a regular basis?
@rupe53
@rupe53 2 года назад
I would guess there's a special task force to handle that aspect of doing a full service. I would also surmise they have extra oil in there so the level stays above acceptable for the 10 year service interval.
@Bobsdecline
@Bobsdecline 2 года назад
That's correct!
@DrRChandra
@DrRChandra 2 года назад
If you're extracting oil, what is supposed to replace its volume? You mentioned not wanting to contaminate the oil with whatever is in air, but that seems to be the only rational thing that would replace the volume of oil you're removing for sampling.
@Bobsdecline
@Bobsdecline 2 года назад
The oil gets topped off every 5-6 years. I may have worded wrong in the video; when the oil is exposed during top up, that's fine. What the syringe sample is trying to accomplish is to capture and gases in the oil as a result of small arcing during many tap changes. The gases would escape from the jar sample much in the same way as CO2 escapes after pouring a glass of Pepsi. Keeping the sample contained helps trap and analyze these gases
Далее
Hooking up underground power
15:29
Просмотров 184 тыс.
The most deadly project on the Internet
15:14
Просмотров 7 млн
🦊🔥
00:16
Просмотров 764 тыс.
这位大哥以后恐怕都不敢再插队了吧…
00:16
Many Moving Magnets Melting Metal
20:21
Просмотров 2,9 млн
Electrician Reacts to Styropyro's🔌AMPS vs VOLTS⚡
15:26
Homeowner reports partial power !?
15:14
Просмотров 138 тыс.
69kV Substation w/Trip savers
15:34
Просмотров 22 тыс.
Changing blown transformer!
30:58
Просмотров 380 тыс.
No power!... all cutouts are closed !?
23:21
Просмотров 128 тыс.
Removing an old "A" base Electrical meter
25:14
Просмотров 168 тыс.
Being a Lineman - Episode 13
20:30
Просмотров 53 тыс.
Power outage response - Virtual ride along!
15:07
Просмотров 41 тыс.
🦊🔥
00:16
Просмотров 764 тыс.