Faulty immersion heater, testing tips UK electrician. TIS MFT Pro 

Mark The Sparky Allison
Подписаться 14 тыс.
Просмотров 22 тыс.
50% 1

A look at some of the testing we can do on immersion heater elements and the reasons why.
Utilising the TIS mft Pro to illustrate clearly measurements obtained.
Not paid or sponsored, not that it matters!
Also this is for entertainment purposes only.

Опубликовано:

 

14 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 26   
@rockonrory1
@rockonrory1 11 месяцев назад
Superb in depth video Mark. Almost had dejavu watching this. had exactly the same call out last week. Good stuff mate!!!👍
@homeschoolelectrics4323
@homeschoolelectrics4323 3 года назад
Thank you. Really useful video.... it's almost like being onsite and gaining experience. Appreciated. Just done a final ring circuit and practising the testing at college.
@electrician247
@electrician247 3 года назад
Great stuff. Rings are good to learn testing on! GSH/EFIXX did a great video on that in the past.
@homeschoolelectrics4323
@homeschoolelectrics4323 3 года назад
just heading off now to Thursday evening workshop with Jon at Bradford College (he's a bit like Gary as GSH)! Thanks again
@paultipton743
@paultipton743 3 года назад
I did an eicr today which is prior to changing the consumer unit, it is currently a square D consumer unit with type 1 mcbs, ground floor sockets mcb had a ringmain plus 2 radials for 2 heaters (4 Lives), 1st floor socket circuit had ringmain and 2 radials to heaters as well, a right game trying to get them back in the mcb's after for the mcb terminals to grip all 4 wires... extra mcbs or rcbos required for the new consumer unit I'd say. Have to say I havent done an eicr for a couple of years nice to have a change
@mathman0101
@mathman0101 3 года назад
Nice one. Always useful, when was the tank installed always provides a clue about fault finding and element problems.
@electrician247
@electrician247 3 года назад
Thats an unknown but I think around 5-10 years ago.
@mathman0101
@mathman0101 3 года назад
@@electrician247 it’s around the 10 year anniversary that you often see problems we have the same issue on US of course internal corrosion and water chemistry play a part as well.
@jj-hn2ll
@jj-hn2ll 3 года назад
Don't worry i am not stalking you 😎 . Vids getting more interesting every time i watch.
@electrician247
@electrician247 3 года назад
Thanks for all the comments really appreciate it!
@SqwarkParrotSpittingFeathers
@SqwarkParrotSpittingFeathers 3 года назад
What a really good explanation and informative vid. Just found your channel. Waiting eagerly for more. Thanks.
@electrician247
@electrician247 3 года назад
Thank you!
@garylatto4191
@garylatto4191 Год назад
Mark whats the formula to work out what resistance you would expect on the element?. Cheers keep up the vids 👍
@efledasongalia1375
@efledasongalia1375 3 года назад
Good video. Thank you very much.
@billsbasementworkshop1902
@billsbasementworkshop1902 2 года назад
Hi Mark, Before you did the insulation resistance test, did you drain down the tank?
@electrician247
@electrician247 2 года назад
Humm this was a long time ago now so can't remember is the honest answer. I think it was empty as we replaced the element.
@billsbasementworkshop1902
@billsbasementworkshop1902 2 года назад
Sorry forgot tho thank you another for a great vid.
@TheBeardedSpark
@TheBeardedSpark 3 года назад
30 second job into 20 minutes you robbing bastard 🤣 Great video mate, I see this so often lol. Timer wrong, turned off, stat tripped most common things I see.
@electrician247
@electrician247 3 года назад
Should have made half day out of it! 😂 very common isn’t it Ricky.
@paultipton743
@paultipton743 3 года назад
With doing insulation resistance tests at the element. Will it effect the timeclock which has an electronic circuit board?, unless you disconnected the load side of the time clock
@electrician247
@electrician247 3 года назад
100% it would Paul. In this case the timeclock is connected on to the stat. By removing it from the prongs on the element the timeclock s disconnected. Leaving just the heating element in the firing line! Great point to highlight though, very important to consider equipment likely to be damaged by testing.
@paultipton743
@paultipton743 3 года назад
@@electrician247 that's good I should of looked closer, i thought you left it connected still. By the way do those cylinder thermostats just pull out?as I'm OK with the standard copper cylinder ones but the invented type seem to be in more solidly fixed, I've do a lot of immersion testing and replacement on standard copper cylinders but been a bit wary of the Thermtec type with removing the stats.
@electrician247
@electrician247 3 года назад
@@paultipton743 I don’t mess with the wet stuff lol. Especially pressurised tanks like these. Leave it for the plumbers for me lol. These are nice to test on as the stat simply pulls off. I mention it early in the video. Great point to highlight 100% though. Thanks
@electrician247
@electrician247 3 года назад
@@paultipton743 sorry you say stats not the elements. Yeah they just pull out easy. At least these ones do.
@RichardArblaster
@RichardArblaster 3 года назад
Great video 😎
@electrician247
@electrician247 3 года назад
Thanks 😁
Далее
Immersion Heater - Fault Finding
20:19
Просмотров 47 тыс.
You cant have an EV charger in your garage....
15:11
Can you use an outdoor consumer unit in the rain ???
21:04