Febco 765 Sprinkler Backflow Repair 

Castle Rock Lawn & Sprinkler
Подписаться 496
Просмотров 37 тыс.
50% 1

John Lane demonstrates how to complete the most common repair for a Febco 765 backflow unit.
Based on his experience, John recommends using only Febco original parts. Most common residential backflows are either 3/4" or 1" in size and usually match the pipe size to which the backflow is attached.
From Amazon:
Febco 765, 3/4" backflow poppet and bonnet assembly: amzn.to/3b8q9Gn
Febco 765, 1" backflow poppet and bonnet assembly: amzn.to/3ceQp1L
Visit Us: castlerockspri...

Опубликовано:

 

5 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 86   
@mcopilotpro5427
@mcopilotpro5427 4 месяца назад
Thank you John. Great, simple presentation. Important, but small, point you made regarding reintroducing water after making the repair. I had completed the repair (which I don't think I needed in retrospect), and after opening the supply valve I still had water leaking from the top of the back flow preventer. Your mention of the need for fairly abrupt water pressure to pressurize and seat the springs inside solved my problem. Per another posters' suggestion to reintroduce water pressure slowly when starting an irrigation system in the spring, to avoid a strong water hammer situation and potential damage to other system parts, I had not been turning the supply on quickly enough to pressurize and set the springs inside. Bottom line, opening it quickly did the trick. Thank you again for your helpful video.
@CastleRockSprinklerService
@CastleRockSprinklerService 4 месяца назад
Excellent, nice work getting it going!
@timvandyke4087
@timvandyke4087 4 года назад
I only replaced the o-ring (washer) on the bonnet. Easy 99 cent fix because I got the new o-ring from a mom and pop hardware store. Thanks for the video though, it helped me understand the backflow device.
@MrFlip303
@MrFlip303 Год назад
Yes! Don't forget to abruptly turn on the valve to push the spring into place. If you don't it will leak and make you think it needs replacing. However, they do just need replacing sometimes.
@leonardsackett9568
@leonardsackett9568 4 месяца назад
Your presentation was excellent. You talked at a medium speed and you voice was clear.
@CastleRockSprinklerService
@CastleRockSprinklerService 4 месяца назад
Glad you liked it
@gatormccluskey3708
@gatormccluskey3708 2 года назад
Only other thing that may happen is when you turn it on it briefly may purge water until it is pressurized and does not mean it is installed wrong it will seal.
@brettburbank4640
@brettburbank4640 3 года назад
Great video! Thanks. My sprinkler service recently blew out my lines and took the parts! I can’t believe it.
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Can't imagine why they would do it. Glad you were able to get things back together.
@tonybokon8770
@tonybokon8770 3 года назад
Thank You ...You are a master of communication as you explained every detail including the content of the package. One question- is the nut in the package for the canopy? Thanks again...
@carlozpacheco3286
@carlozpacheco3286 2 года назад
Thank you I did what to recommend buy the febco Original and worked beautifully easy explanation and got it fixed
@csApollo11
@csApollo11 3 года назад
Thanks for the great vid! This was on point, high-quality, professional video. I'm impressed! Thanks again from Houston.
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Thanks for the kind words. Good to know it was helpful.
@ianhays4716
@ianhays4716 4 года назад
Thank you. You just saved me $150
@SamoaLouPele
@SamoaLouPele Год назад
GREAT video. REALLY helped us to fix our sprinklers. THANK YOU!! :D :D :D :D :D
@CastleRockSprinklerService
@CastleRockSprinklerService Год назад
So glad!
@not6bucks338
@not6bucks338 4 года назад
Thanks John, you saved me money! 👍
@CastleRockSprinklerService
@CastleRockSprinklerService 4 года назад
Excellent!
@trustnguyen1851
@trustnguyen1851 3 года назад
Thanks
@mgvillegas7912
@mgvillegas7912 3 года назад
Thank you so much for posting this video. You saved me $250, this is what I was quoted to replaced it. I paid $52 on Amazon and replaced it myself. Your video was excellent.
@machina_aeterna
@machina_aeterna 2 года назад
I broke the bolt by over tightening the bonnet bell cap. I drilled 2 wholes in the cap and threaded string through the holes to get it to stay put, but I saw that the cap should be loose, which it is not with my DIY repair. Does the bell cap really need to be loose?
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
Hey man. Nice work around to keep the top on the assembly. The cap is really non essential to the function of the device. So as long as the stings don’t obstruct and the thing is not leaking call it good. By the way, I keep an insulted cover over my back flow assembly year around. Sure isn’t required but I like the extra level of protection. Thanks for sharing your experience
@karenl.4661
@karenl.4661 4 года назад
Good instructions. So how do you know if you have a one inch or three-quarter inch Febco 765-1?
@mary7027
@mary7027 4 года назад
it should state on the brass part
@randylee2549
@randylee2549 9 месяцев назад
awesome!
@badhalf
@badhalf 2 года назад
Great video.. much appreciated! It looks almost like changing a faucet cartridge and I can do that! Haha Cheers!
@SuperNalabear
@SuperNalabear 4 года назад
Ok, I did it. I followed your directions to a T (thin washer, added the grease, seated backwards till it felt flushed, then tightened it, added cap, and open the system abruptly). The system didn't leak after I swapped the large gasket with the smaller one. Is there another way to find out which gasket size actually belongs to my system? I'm not the original owner?
@CastleRockSprinklerService
@CastleRockSprinklerService 4 года назад
Yes, see the channel where the o ring will seat, this is at the top of the threads. Test both rubber rings to determine which one fits best in the channel.
@catgirl24
@catgirl24 2 года назад
Both handles to turn off the water flow on mine are in the back instead of the front. Is that uncommon? I don't know why that is. The sprinkler system was installed already when I bought the house. Every DIY video I've seen, they are in the front.
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
Only on handle is required to turn off the flow. However in your situation I would turn both to the off position. The installer was lazy and did not rotate the ball valves to face forward or it was installed backwards. I’m guessing lazy. Don’t concern yourself with the position as long as the unit works and the handles are not obstructed.
@mary7027
@mary7027 4 года назад
I have replaced all the inner parts and it is still not working, any ideas?
@mary7027
@mary7027 4 года назад
I fixed it! As I watched the video I realized I put on the thin rubber washer instead if the thicker one! So I changed it and it worked!!!! Thank you
@sunsetpond
@sunsetpond Год назад
Actually the parts are the same price as a whole new febco PVB! frustrating- also, I tried to save money and bought an aftermarket set and it lasted only 1 month.
@angeladisante549
@angeladisante549 4 года назад
Hi John, Great info. I am having unit tested for city ordinance. Had a freeze repair and blowout last fall. Should check valve be replaced before having unit tested?
@CastleRockSprinklerService
@CastleRockSprinklerService 4 года назад
Thanks Mark. If the clip and spring remained in place then during the freezing episode then the check valve should be okay. I would pull it apart and look for any for any damage. If you see nothing then you are good to go. I don't often see the check get damaged during freezing events. Hope the process is uneventful. Best to you Mark.
@SuperNalabear
@SuperNalabear 4 года назад
I replaced the Bonnet/Poppet and it worked fine for about 3 weeks. Then it started leaking again. I found the gasket bulged out to the side (I used the large one). I just tried using the smaller gasket but the system continues to leak with the smaller. I'm planning on returning the item to Lowes and getting a new one. But any ideas on why the system failed so quickly?
@CastleRockSprinklerService
@CastleRockSprinklerService 4 года назад
Looks like you resolved the issue with the comment below.
@ryanharter711
@ryanharter711 4 года назад
Hey John, my Febco test cock is leaking slightly. I don't see replacement parts around CR. Any easy way to just repair this? It's just a drip about every 10 seconds. Thanks John, love the videos!
@CastleRockSprinklerService
@CastleRockSprinklerService 4 года назад
Hi Ryan, best to not let it drip the entire season. You can find a testcock on Amazon, Febco 1/8 Male x 1/4 female. The item is available at DBC located at 18810 Longs Way, Parker. Thanks for the kind words. JL
@fortbowie1
@fortbowie1 3 года назад
John, After I replaced those pieces I turned the valve on & right below below on the “neck” of the “brass piece”, water squirted out & it appears there’s a super duper small crack or hole in the brass piece, it’s only squirting out when I turn the water valve right there on & once pressurized it is barely leaking out of the “T” where you screwed the plastic into,, it’s right below that. Do I have to buy another poppet kit or does that brass “T” come with it? I just replaced that yesterday. Any help would be grateful.
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Hi. Please send picture pointing out where you find the water leak. Even better send a video of the dripping. John@castlerocksprinkler.com
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Hey man, I did not see the email. Try again, John@castlerocksprinkler.com
@samd3272
@samd3272 2 года назад
Hi John. Thank-you for the excellent video. I replaced the Febco 765-BP bonnet and poppet. I turned the valve back to the open position and it sealed perfectly...for about a minute or two. Then I heard a hissing noise and a fine spray appeared. I shut the valve, removed the bonnet and poppet to inspect the o-rings. No crimps and they were both correctly positioned and lubricated. Re-installed and same result only in a different location around the seal. Tried a third time. This time it doesn't spray but there is a very slight drip. Any suggestions? Thanks.
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
Hi Sam. Thanks for the kind words. Did you intend to say O ringS? There should only be one O ring on the assembly. The package contains 2 rings: a thick and a thin. Please replace the ring with the same type as was in the assembly you removed. Let me know if this is the issue of if I just misread your reply Ans we will go from there. John
@samd3272
@samd3272 2 года назад
@@CastleRockSprinklerService I should have said O ring. I chose the thicker one since that was what was on the assembly that I removed. The system ran a full cycle this morning and I was hoping the dripping was caused by a pressure imbalance. Nope. It's still dripping. It makes no sense. This should be a simple as changing a light bulb. I'll try it again today. If I still have an issue, I'm thinking about trying plumbers tape.
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
Hi Sam. Please send a video of the dripping to john@castlerocksprinkler.com. Yes, I agree with you it should seal up and not leak. Perhaps the freezing event distorted the housing but that seems unlikely.
@samd3272
@samd3272 2 года назад
@@CastleRockSprinklerService Hi John. No need, I fixed it! I switched out the thicker O ring for the thinner one. It has a good seal now. Thank-you for your help!
@area.man.
@area.man. 3 года назад
What would cause this to happen on a brand new poppet and bonnet? I'm trying to get this going for the first time at this residence. I'm in your neck of the woods so you know how bad the grass burns if not watered. Trying to get this going before my front and back lawns turn into the dust bowl.
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Consider dragging a hose until you are able to get the system operating. I’m not certain what is happening with the back flow. However, if you installed new parts and the BF won’t hold pressure them watch the system startup video. Let me know more details if that doesn’t help and we can figure it out together.
@area.man.
@area.man. 3 года назад
@@CastleRockSprinklerService It was acting very strange when I did the startup. I did the same technique in the video. However when I closed the valve at the end of the line, the main pipe started chugging and water started coming out of the top of the bell canopy. I replaced the poppet and bonnet and now water just comes out of the top right away and does not stop when I turn on the lower inlet valve. I had to manually manipulate the poppet up and then it flowed but then just comes out of the top when closing the valve at the end again. I am going to look for the Febco poppet today, I bought one of the aftermarket ones you said to stay away from because the stores did not have the Febco one.
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
@@area.man. the installed parts are likely okay. You have a pressure problem down stream. I would be looking for an open drain valve in a manifold box as well as a zone which is open. Or there could be a leak in the main line which leads to the valve boxes. Start hunting down the reason you can’t pressurize the main line. Don’t be co corned for the backflow parts at this point.
@area.man.
@area.man. 3 года назад
@@CastleRockSprinklerService There is a valve I closed in the manifold box, it has an open end so thinking that is where the system drains. Water was flowing freely out of the end of that. When I turned that valve closed that is when the line started chugging amd water came out of the bonnet. That prompted me to replace the poppet and bonnet.
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
@@area.man. keep looking for more down stream leaks or open drains.
@mary7027
@mary7027 3 года назад
I have replaced the inside parts and it worked for a bit but now it's leaking again up through the bell and I am not sure why. All the inner parts are new! Help please?
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Hi. Did you remember to install the o-ring? The black, rubber ring?
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
I would suggest taking the parts out. Checking for the ring, be sure the grease was applied to the treads and then replace the parts. Be sure the threads seat properly as it should be very easy hand tighten the parts.
@mary7027
@mary7027 3 года назад
@@CastleRockSprinklerService yes
@mary7027
@mary7027 3 года назад
@@CastleRockSprinklerService I did take the parts out and examined them. all looks good. I have re greased the o ring but not the threads.
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Has there been freezing weather since the parts have been replaced ?
@garbagemanpiper
@garbagemanpiper 3 года назад
The nut loosens but won’t come off it just spins? Help! I have the part🙏
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
Understood. Are you able to just lift up on the bell cover and pull it out. I’ve seen what you are experiencing, the freeze damage inside cracked the center post which holds the bolt. You can be aggressive as you attempt to get that cover off. If push comes to shove then try to get ahold of the post with a needle nose to stop the spinning while you turn the nut.
@garbagemanpiper
@garbagemanpiper 3 года назад
@@CastleRockSprinklerService I was worried I would bend the cover? I am usually a bull in a China shop so didn’t push it to hard. I will give it another go. I very much appreciate you responding brother!
@garbagemanpiper
@garbagemanpiper 3 года назад
@@CastleRockSprinklerService no go on grabbing the pipe with need nose can’t lift it with the bell housing. Used WD40 to try and loosen it up. The tap the fins down below no go. Would it hurt anything to just chip the plastic valve away and take it of in pieces?
@CastleRockSprinklerService
@CastleRockSprinklerService 3 года назад
@@garbagemanpiper Go for it. Just get it out of there. Good luck GMP! 🙏🏾
@garbagemanpiper
@garbagemanpiper 3 года назад
@@CastleRockSprinklerService Thanks for the encouragement 👍
@judyl.761
@judyl.761 2 года назад
Where can I find a cap (umbrella on the very top of system)? I misplaced mine.
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
4.5 out of 5 stars68 Reviews Canopy for 1" & 1-1/4" 765 Backflow Preventer 765EBV Vacuum Breaker by Febco
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
Amazon has a canopy for a one inch back flow. I don’t see a cover for a 3/4” back flow
@judyl.761
@judyl.761 2 года назад
@@CastleRockSprinklerService Thanks, I need 3/4”.
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
sprinklersupplystore.com/products/febco-canopy-765-3-4?variant=43671906249&gclid=Cj0KCQjwg_iTBhDrARIsAD3Ib5jAW9gPSmGer9GSY1ew5RDPdHXvHtkKceGNsaCjnAviBNNJB-M8zycaAil6EALw_wcB
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
Here you go:sprinklersupplystore.com/products/febco-canopy-765-3-4?variant=43671906249&gclid=Cj0KCQjwg_iTBhDrARIsAD3Ib5jAW9gPSmGer9GSY1ew5RDPdHXvHtkKceGNsaCjnAviBNNJB-M8zycaAil6EALw_wcB
@garyaustin849
@garyaustin849 2 года назад
Weak spring causes check to fail
@CastleRockSprinklerService
@CastleRockSprinklerService 2 года назад
I’ve never seen a weak spring be the cause of a failure. I have seen low water pressure not be able to hold the bonnet and popit closed. A weak spring would allow a low pressure issue to perhaps keep things sealed up.
@itsokaytobestupid827
@itsokaytobestupid827 3 года назад
Asse stopped issuing you hacks backflow rebuilder certificates, don't touch them anymore.
@1slowens
@1slowens Год назад
AHHHHH, 1st thing to do is MAKE SURE THE WATER IS OFF OR THE BALL VALVE BEFORE THE BACK FLOW PREVENTER IS OFF.
@1slowens
@1slowens Год назад
ATTABOY!,,,ALL GUNS ARE LOADED UNTIL PROVEN OTHERWISE!
@1slowens
@1slowens Год назад
EmberASSing. there are no washers. Those are o-rings, the white grease only needs to be on the o-ring prior to pushing into position. Because of your years of experience. I'd be willing to betcha' that if you merely removed the original o-rings, grease them, and then reinstalled them....ALL would be fine. Nice sweater, looks very professional. I won't be calling you.
Далее
Fixing Your Febco 765-1 PVB
7:41
Просмотров 263 тыс.
Mcdonalds cups and ball trick 🤯🥤 #shorts
00:25
Просмотров 354 тыс.
Тренд Котик по очереди
00:10
Просмотров 302 тыс.
TRENDNI BOMBASI💣🔥 LADA
00:28
Просмотров 854 тыс.
How To: Replace Backflow Preventer
25:30
Просмотров 46 тыс.
Replacing A Febco 765 Check Valve
4:07
Просмотров 21 тыс.
Broken Backflow Preventer, How to Repair
7:47
Просмотров 446 тыс.
QUICKLY REPAIR FEBCO 765 Vacuum Breaker
4:04
Просмотров 57 тыс.
lawn sprinkler backflow preventer replaced
15:02
Просмотров 75 тыс.
Backflow Preventer Repair
4:13
Просмотров 224 тыс.
Replacing Sprinkler Shut off Valve
10:20
Просмотров 10 тыс.
Mcdonalds cups and ball trick 🤯🥤 #shorts
00:25
Просмотров 354 тыс.