Replacing Sprinkler Shut off Valve 

Tony Bahri
Подписаться 425
Просмотров 8 тыс.
50% 1

How to replace an irrigation sprinkler system shut off ball valve, Febco 765 back-flow preventer vacuum breaker. Changing a damaged and leaking shut off valve. Any Brand sprinkler system.

Опубликовано:

 

28 май 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 16   
@hans-onplumbingdraincleani5266
Use enough Teflon?
@chez18788
@chez18788 2 месяца назад
Helpful video thanks!!!
@tonybahri
@tonybahri 2 месяца назад
You’re welcome and thank you for the support
@prawnstar9213
@prawnstar9213 29 дней назад
Do they make right handed backflow preventers? The pipe leading to the sprinklers is to the right of the pipe coming out of the house and so the shut off valve sits against the house because they installed a left handed one backwards. Also, what if your state requires that only a plumber with an ASSE certification fix your backflow.. I mean they won’t know.. so who cares right? or is there a permit process?
@tonybahri
@tonybahri 27 дней назад
You can use the same one just turn the shut off valves the other way, but has to be taken apart for adjustments. I think most states require a permit or license plumber to install back flows but not for repairs.
@johnlopez8349
@johnlopez8349 Месяц назад
You're the man! Thank you!
@tonybahri
@tonybahri Месяц назад
You’re welcome. Thanks for the support
@hans-onplumbingdraincleani5266
Back up wrench
@markLikesSports
@markLikesSports 4 месяца назад
You are putting too much force on the existing piping. Support the existing piping with a second pipe wrench or another tool. What are you going to do if the pipe attached to the spigot breaks off or becomes compromised inside the wall or house?
@tonybahri
@tonybahri 4 месяца назад
Hello. I wouldn’t say it’s too much force. Pretty much threading the new valve on, and just tightening it enough with the wrench. One Inch copper pipe is pretty heavy duty. I would be able to feel if I was going to twist the pipe or do damage. Then I would grab a 2nd wrench. Still have to be cautious. Most times, I do use 2 wrenches when there is a shark-bite fitting inside and the pipe starts spinning. 3/4” I just remove the whole unit and use a vice grip, then solder it back onto the main line.
@joec632
@joec632 Месяц назад
shouldn't you have let the copper cool down more before turning the water on? just curious. not judging
@tonybahri
@tonybahri Месяц назад
I did let it cool down for about five minutes or so naturally. I don’t want to cause any stress cracks. Usually, by the time I put away all my stuff away. I start heading inside and then turning the water on.
@DennisGilmoreHomeLoans
@DennisGilmoreHomeLoans 28 дней назад
Very useful video thank you
@tonybahri
@tonybahri 27 дней назад
You’re welcome. Thanks for the support
@carmencristantiello5176
@carmencristantiello5176 Год назад
next time use a slip coupling
@tonybahri
@tonybahri Год назад
You can use a slip coupling (Sharkbite) like I mentioned in the video. They’re not the best for permanent connections, they have rubber o-rings which dry rot and cause stress cracks over time.