Тёмный

Fire Alarm Devices 

Craig Michaud- Electrical Instructor
Подписаться 60 тыс.
Просмотров 14 тыс.
50% 1

In this video we explain how to install Fire Alarm devices.

Хобби

Опубликовано:

 

10 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 28   
@RicardoDelgado-zr4ki
@RicardoDelgado-zr4ki 2 месяца назад
Very informative. Thanks for the info about this and your advice on how it works
@allanpita2221
@allanpita2221 Месяц назад
Dude the best explanation yet
@raycaballero6386
@raycaballero6386 Год назад
Your a very straight forward instructor that does a tremendous service in sharing your advanced skills and knowledge with your viewers. Thanks for what you do for us
@davidredpath4781
@davidredpath4781 3 года назад
Great video, Mr. Michaud! I have had to fix so many of devices installed incorrectly due to a lack of education or because people didn’t care. I really like how detailed you were and how you took the time to explain the wiring method and how to properly use a resistor at the EOL. Thank you for taking the time to make these videos. It helps a lot of people! I will definitely be passing this video along to others! Dave
@c4withit
@c4withit 5 лет назад
It’s all about the addressable systems now Mr. M! Great video!!
@craigmichaud-electricalins4602
Connor Madden I agree but this is just the first part. Next will be wiring a panel and then off to Addressable systems. Thanks for watching!!
@JPerez-ld6nb
@JPerez-ld6nb 2 года назад
It’s all about that smart system. Thanks for the video
@cuco176
@cuco176 10 месяцев назад
This video was great. Using this as a resource for knowledge. Thank you !
@virgilf3
@virgilf3 Год назад
Installing my first fire panel, thank you
@FireAlarm33
@FireAlarm33 7 месяцев назад
Very cool!!!
@hlhl5962
@hlhl5962 7 месяцев назад
very detailed and clear explanation
@achannelwithnopurpose1977
@achannelwithnopurpose1977 2 года назад
A thing I like to do when I wire is label everything. It makes going through lines and troubleshooting much easier as I don’t have to figure out what wire is for which connection/application
@4abettaworld
@4abettaworld Год назад
Thank you Sir, much appreciated
@ronaldmedina2129
@ronaldmedina2129 6 месяцев назад
Very helpful information 👌
@V21IC
@V21IC Год назад
This is a great 👍🏼
@brodiecollins4304
@brodiecollins4304 2 года назад
So clear and simple
@elsiebonilla7445
@elsiebonilla7445 3 года назад
Thank you !
@manuelvalladares5004
@manuelvalladares5004 5 лет назад
Nice
@X410zee
@X410zee 2 года назад
My instructor taught me to put the resistor under each wire to get a good connection. The other positive I leave empty. Thought?
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 2 года назад
With some detectors that maybe the case. Not these!! If you don’t put the resistor on the open positive the zone loop is not supervised!! Meaning if something is wrong with the zone the panel won’t know. It’s important to have the panel show a trouble in the circuit in order for a proper installation! In 30 years I have seen a lot of different systems never once did I put the wire and resistor on the same side of the screw!! Hope that helped you!! CM
@malawigold747
@malawigold747 8 месяцев назад
Can I connect them without a resistor? Just black in negative and red in either positive?
@shielatalampas5544
@shielatalampas5544 2 года назад
do all fire alarm devices can run in 1 conduit?
@stephenhart6158
@stephenhart6158 2 года назад
why on the smoke detector and the notification device did you have one set of wires, on the pull station you had two?
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 2 года назад
This was a lab demonstration on device connections. CM
@stephenhart6158
@stephenhart6158 2 года назад
@@craigmichaud-electricalins4602 thanks Craig 12pm in Australia not sure what you mean by lab demonstration should there be one or two set of wires to the pull station. have you done a video on addressable panels? I know very little about fire panels and thought addressable panels had an inbuilt ability to locate individual devices. I didn't realise until recently that you have to install an addressable module to each device so that the FCP can locate it. It appears to me that each individual FCP manufacturer have their own specific modules just to suit their panels. Wouldn't it be smart for someone to have a universal one that would suit all panels. thanks for your info Steve
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 2 года назад
Yes absolutely but this is a conventional fire alarm system. I use these videos to show my students things they will learn in the lab. There are a lot of different situations on how to wire fire alarm. Looks like you are doing some good research!! CM
Далее
Fire Alarm Control Panel and Testing Devices
10:31
Просмотров 11 тыс.
Nurse's dream !! 😂😂
00:17
Просмотров 3,7 млн
Каха и калЪян
00:46
Просмотров 86 тыс.
Fixing Fire alarm HVAC shutdown problem
36:49
Просмотров 6 тыс.
Fire Alarm Systems 101
8:00
Просмотров 32 тыс.
Fire Alarm Training
15:07
Просмотров 234 тыс.
How To Design A Fire Alarm System According To NFPA 72
34:38
Finding General Lighting Load for Dwellings
16:59
Просмотров 94 тыс.
How To Wire Up Fire Alarms Without a Panel
9:54
Просмотров 27 тыс.
SLC Installation
9:01
Просмотров 3 тыс.
Basic understanding how a Holding relay wired
12:13
Просмотров 60 тыс.
Why Neutrals and Grounds are Separated in a Sub Panel
17:46
Who has won ?? 😀 #shortvideo #lizzyisaeva
0:24
Просмотров 34 млн
УДИВИЛА МЛАДШУЮ СЕСТРУ
0:50
Просмотров 5 млн